References
Barker, S. J., andTremper, K. K. (1987): ‘The effect of carbon monoxide inhalation on pulse oximetry and transcutaneous SpO2’Anesthesiol.,66, pp. 677–679
Borgström, P., Clementz, L.-Â., andGrände, P.-O. (1981): ‘A servo-controlled roller pump for constant flow or constant pressure blood perfusion under normal pulsatile or nonpulsatile conditions’,Acta Physiol. Scand.,112, pp. 437–442
Burch, G. E. (1954): ‘Digital plethysmography’ (Grove and Stratton, New York).
Challoner, A. V. J. (1979): ‘Photoelectric plethysmography for estimating cutaneous blood flow’inRolfe, P. (Ed.) ‘Noninvasive physiological measurements, Vol. 1’ pp. 127–151
Clayton, D. G., Webb, R. K., Ralston, A. C., Duthie, D., andRunciman, W. B. (1991): ‘A comparison of the performance of 20 pulse oximeters under conditions of poor perfusion’,Anaesthesia,46, pp. 3–10
Eisenkraft, J. B. (1988): ‘Pulse oximetry desaturation due to methemoglobinemia’,Anesthesiol.,68, pp. 279–282.
Frewer, R. A. (1974): ‘The electrical conductivity of flowing blood’,Biomed. Eng.,9, pp. 552–555
Hovagim, A. R., Backus, W. W., Mancke, G., Lagasse, R., Sidhu, U., andPoppers, P. J. (1989): ‘Pulse oximetry and patient positioning: a report of eight cases’,Anesthesiol.,71, pp. 454–456
Kim, J. M., Arakawa, K., Benson, K. T., andFox, K. K. (1986): ‘Pulse oximetry and circulatory kinetics associated with pulse volume amplitude measured by photoelectric plethysmography’,Anesth. Analg.,65, pp. 1333–1339
de Kock, J. P. andTarassenko, L. (1991): ‘In vitro investigation of the factors affecting pulse oximetry’,J. Biomed. Eng.,13, pp. 61–66
Lee, S., Tremper, K. K., andBarker, S. J. (1991): ‘Effects of anemia on pulse oximetry and continuous mixed venous haemoglobin saturation monitoring in dogs’,Anesthesiol.,75, pp. 118–122
Ley, K., Lindbom, L. andArfors, K. E. (1988): ‘Haematocrit distribution in rabbit tenuissimus muscle’,Acta Physiol. Scand.,132, pp. 373–383
Lindberg, L.-G., andÖberg, P. Å. (1991): ‘Photoplethysmography. II. Influence of light source wavelength’,Med. Biol. Eng. Comput.,29, pp. 48–54
Lindberg, L.-G., andÖberg, P. Å. (1993): ‘Optical properties of blood in motion’,Opt. Eng.,32, pp. 253–257
McDonald, D. A. (1974): ‘Blood flow in arteries’ (Camelot Press Ltd., Southampton, UK).
Mendelson, Y., andKent, J. C. (1989): ‘Anin vitro tissue model for evaluating the effect of carboxyhemoglobin concentration on pulse oximetry’,IEEE Trans.,BME-6, pp. 625–627
Morris, R. W., Nairn, M., andTorda, T. A. (1989): ‘A comparison of fifteen pulse oximeters. Part I: A clinical comparison; Part II: A test of performance under conditions of poor perfusion’,Anaesth. Intens. Care,17, pp. 62–82
Sakamoto, K., andKanai, H. (1979): ‘Electrical characteristics of flowing blood’,IEEE Trans.,BME-12, pp. 686–695
Schmid-Schönbein, H. (1981): ‘Interaction of vasomotor and blood rheology in haemodynamics’,in: Lowe, G. D. O., Barbenel, J. C., and Forbes, C.D., (Eds.): ‘Clinical aspects of blood viscosity and cell deformability’ Springer Verlag, New York, pp. 56–57
Sendak, M., Harris, A., andDonham, R. (1988): ‘Accuracy of pulse oximetry during arterial oxyhemoglobin desaturation in dogs’,Anesthesiol.,68, pp. 111–114
Severinghaus, J. W., andKoh, S. O. (1990): ‘Effects of anemia on pulse oximeter accuracy’,J. Clin. Monit.,6, pp. 85–88
Severinghaus, J. W., andSpellman, M. J. (1990): ‘Pulse oximeter failure thresholds in hypotension and vasoconstriction’,Anesthesiol.,73, pp. 532–537.
Shepherd, A. P., Riedel, G. L., Kiel, J. W., Haumschid, D. J., andMaxwell, L. C. (1987): ‘Evaluation of an infrared laser-Doppler flowmeter,’Am. J. Physiol.,252, pp. G832–839
Taylor, M. B., andWhitwam, J. G. (1988): ‘The accuracy of pulse oximeters,’Anaesthesia,43, pp. 229–232
Tremper, K., andBarker, S. (1989): ‘Pulse oximetry,’Anesthesiol,70, pp. 98–108
Vegfors, M., andLennmarken, C. (1991a): ‘Carboxyhaemoglobinaemia and pulse oximetry,’Br. J. Anaesthiol.,66, pp. 625–626
Vegfors, M., Lindberg, L.-G., Öberg, P. Å., andLennmarken, C. (1991b): ‘The accuracy of pulse oximetry at various haematocrits and during haemolysis in anin vitro model,’Med. Biol. Eng. Comput.,31, pp. 135–141
Vegfors, M., Lindberg, L.-G. andLennmarken, C. (1992a): ‘The influence of changes in blood flow on the accuracy of pulse oximetry in humans,’Acta Anaesthesiol. Scand.,36, pp. 346–349
Vegfors, M., Lindberg, L.-G., Öberg, P. Å., andLennmarken, C. (1992b): ‘The accuracy of pulse oximetry at two haematocrit levels,’Acta Anaesthesiol. Scand.,36, pp. 454–459
Yelderman, M., andNew, W. (1983): ‘Evaluation of pulse oximetry,’Anesthesiol.,59, pp. 349–352
Zdrojkowski, R. J., andPisharoty, N. R. (1970): ‘Optical transmission and reflection by blood,’IEEE Trans.,BME-17, pp. 122–128
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Lindberg, L.G., Vegfors, M., Lennmarken, C. et al. Pulse oximeter signal at various blood flow conditions in anin vitro model. Med. Biol. Eng. Comput. 33, 87–91 (1995). https://doi.org/10.1007/BF02522952
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02522952