Abstract
Recent advances in the development of transducers for the measurement of vertical and shear forces acting on the plantar surface of the foot are reviewed. Barefoot and in-shoe discrete and matrix transducers are reviewed in terms of structure, operation, performance and limitations. Examples of capacitive, piezoelectric, optical, conductive and resistive types of transducer are presented. Where available, the current clinical status is specified.
Similar content being viewed by others
References
Akhlaghi, F., Pepper, M.,et al. (1993): Assessment of in-shoe foot pressure patterns over multiple footsteps.Proc. IPSM/HPA 49th Ann. Conf., Lincoln, UK, p. 68
Akhlaghi, F., Daw, J.,et al. (1994): In-shoe step-to-step pressure variations.Foot,4, pp. 62–68
Alexander, I. J., Chao, E. Y.,et al. (1990): ‘The assessment of dynamic foot-to-ground contact forces and plantar pressure distribution: a review of the evolution of current techniques and clinical applications’,Foot Ankle,11, pp. 152–167
Assente, R., Ferrigno, G.et al. (1985): ‘Distributed multiplexing architecture for PVDF multitransducer platform scanning: a theoretical and practical approach’.Proc. 5th Symp. Electrets, Heidelberg, Germany, pp. 795–800
Bennet, J. P. andDuplock, L. R. (1993): ‘Pressure distribution beneath the human foot’,J. Am. Podiatric Med. Assoc.,83, (12), pp. 674–678
Betts, R. P., Duckworth, T.,et al. (1980a): ‘Critical light reflection at a plastic/glass interface and its application to foot pressure measurements’,J. Med. Eng. Technol.,4, (3), pp. 136–142
Betts, R. P., Franks, C. I.,et al. (1980b): ‘Static and dynamic foot-pressure measurements in clinical orthopaedics’,Med. Biol. Eng. Comput.,18, (5), pp. 674–684
Betts, R. P., Franks, C. I. andDuckworth, T. (1991): ‘Foot pressure studies: normal and pathological gait analysis’ InDisorders of the foot.Jahss, M. H. (Ed.), (W. B. Saunders, Philadelphia, Pennsylvania), Vol. 1, Chap. 18, pp. 484–519
Cavanagh, P. R., Hennig, E. M.,et al. (1985). In: ‘Biomedical measurement in orthopaedic practice’,Whitte, M. (Ed.). (Oxford Science Publications), pp. 159–165
Cavanagh, P. R., Hewitt, Jr., J. E.,et al. (1992): ‘In-shoe plantar pressure measurement: a review’,Foot,2, pp. 185–194
D’Amico, J. C., Dinowitz, H. D.,et al. (1985): ‘Limb length discrepancy—an electrodynographic analysis’,J. Am. Podiatric Med. Assoc.,75, pp. 639–643
Facey, O. E., Hannah, I. D.,et al. (1993): ‘Analysis of the reproducibility and individuality of dynamic pedobarograph images’,J. Med. Eng. Technol.,17, (1), pp. 9–15
Ferguson-Pell, M. W. (1980): ‘Design criteria for the measurement of pressure at body/support interfaces’,Eng. Med.,9, (4), pp. 209–213
Franks, C. I., Betts, R. P.,et al. (1983): ‘Microprocessor-based image processing system for dynamic foot pressure studies’,Med. Biol. Eng. Comput.,21, (5), pp. 566–572
Franks, C. I. andBetts, R. P. (1988): ‘Selection of transducer material for use with ‘Optical’ foot pressure systems’,J. Biomed. Eng.,10, (4), pp. 365–367
Gastwirth, B. W., O’Brien, T. D.,et al. (1991): ‘An electrodynagraphic study of foot function in shoes of varying heel heights’,J. Am. Podiatric Med. Assoc.,81, pp. 463–472
Gross, T. S. andBunch, R. P. (1988): ‘Measurement of discrete vertical in-shoe stress with piezoelectric transducers’,J. Biomed. Eng.,10, (3), pp. 261–265
Hennig, E. M., Cavanagh, P. R.,et al. (1982): ‘A piezoelectric method of measuring the vertical contact stress beneath the human foot’,J. Biomed. Eng.,4, (3), pp. 213–222
Hennig, E. M., Staats, A.,et al. (1994): ‘Plantar pressure distribution patterns of young school children in comparison to adults’,Foot Ankle,15, (1), pp. 35–40
Kothari, M., Webster, J. G.,et al. (1988): ‘Capacitive sensors for measuring the pressure between the foot and shoe’,IEEE Eng. Med. Biol.,2, pp. 805–806
Kynar Technical Manual (1987): Pennwalt Corporation, P.O. Box 799, Valley Forge, Philadelphia, USA
Laing, P.,et al. (1992): ‘The development of the low profile Liverpool shear transducer’,Clin. Phys. Physiol. Meas.,13, (2), pp. 115–124
Lord, M. (1981): ‘Foot pressure measurement: a review of methodology’,J. Biomed. Eng.,3, pp. 91–99
Lord, M. andReynolds, D. P. (1986): ‘Foot pressure measurement: a review of clinical findings’,J. Biomed. Eng.,8, pp. 283–294
Lord, M., Hosein, R.,et al. (1992): ‘Method for in-shoe shear stress measurement’,J. Biomed. Eng.,14, (5), pp. 181–186
Maalej, N. andWebster, J. G. (1988): ‘A miniature electropical force transducer’,IEEE Trans.,BME-35, pp. 93–99
Minns, R. J. (1982): ‘Two simple plantar pressure recording devices in clinical use: evaluation using a pedobarograph’,J. Eng. Med.,11, (3), pp. 117–120
Nevill, A. J. (1991): ‘A foot pressure measurement system utilising PVDF and copolymer piezoelectric transducers’,PhD Thesis. Univesity of Kent at Canterbury, UK
Nevill, A. J., Pepper, M. G. andWhiting, M. (1995): ‘In-shoe foot pressure measurement system utilising piezoelectric transducers’.Med. Biol. Eng. Comput.,33, (1), pp. 76–81
New Scientist (1985): ‘Measuring the weight on your feet’,New Scientist, 13 June, p. 24
Nicol, K. andHennig, E. M. (1978): ‘Measurement of pressure distribution by means of a flexible, large surface mat’. InBiomechanics VI-A, (University Park Press, Baltimore, USA), pp. 374–380
Patil, K. M. andSrinath, M. S. (1990): ‘New image-processing system for analysis, display and measurement of static and dynamic foot pressures’,Med. Biol. Eng. Comput.,28 (5), pp. 416–422
Pedotti, A., Assente, R.,et al. (1984): ‘Multisensor piezoelectric polymer insole for pedobarography’,Ferroelectrics,60, (1–4), pp. 163–174
Peruchon, E., Jullian, J. M.,et al. (1989): ‘Wearable unrestraining footprint analysis system. Applications to human gait study’,Med. Biol. Eng. Comput.,27, (6), pp. 557–565
Pollard, J. P., Le Quesne, L. P.,et al. (1983): ‘Forces under the foot’,J. Biomed. Eng.,5, pp. 37–40
Rhodes, A., Sherk, H.,et al. (1988): ‘High resolution analysis of ground foot reaction forces’,Foot Ankle,9, pp. 135–138
Roggero, P., Blanc, Y.,et al. (1993): ‘Foot reconstruction in weight bearing area: long term results and gait analysis’,Eur. J. Plastic Surg.,16, pp. 186–192
Rose, N. E., Feiwell, L. A.,et al. (1992): ‘A method for measuring foot pressures using a high resolution, computerised insole sensor: the effect of heel wedges on plantar pressure distribution and center of force’,Foot Ankle,13, pp. 263–170
Sensors (1991): ‘A pressure mapping system for gait analysis’.Sensors pp. 21–23
Smith, L., Plehwe, W.,et al. (1989): ‘Foot bearing pressure in patients with unilateral diabetic foot ulcers’,Diabetic Med.,6, pp. 573–575
Tappin, J. W. andPollard, J. P. (1980): ‘Method of measuring shearing forces on the sole of the foot’,Clin. Phys. Physiol. Meas.,1, pp. 83–85
Tappin, J. W. andRobertson, K. P. (1991): ‘Study of relative timing of shear forces on the sole of the forefoot during walking’,J. Biomed. Eng.,13, pp. 39–42
Williams, R. B., Porter, D.,et al. (1992): ‘Triaxial force transducer for investigating stresses at the stump/socket interface’,Med. Biol. Eng. Comput.,30, pp. 89–96
Young, R. C. (1993): ‘The F-scan system of foot pressure analysis’,Clinics Podiatric Med. Surg.,10, (3), pp. 455–461
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Cobb, J., Claremont, D.J. Transducers for foot pressure measurement: survey of recent developments. Med. Biol. Eng. Comput. 33, 525–532 (1995). https://doi.org/10.1007/BF02522509
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02522509