Skip to main content
Log in

Calibration of Micromatter Co. standards used for the calibration of PIXE analysis systems

  • Physical Methods Section
  • Published:
Journal of Radioanalytical Chemistry Aims and scope Submit manuscript

Abstract

The evaluation of the accuracy of thin elemental standards produced by Micromatter Co., which are widely used for the calibration of the detection sensitivity of PIXE analysis systems, is presented in terms of Rutherford scattering measurements of the thickness of 68 standards covering a range of 59 different elements.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Proc. 2 nd Intern. Conf. on PIXE Analysis Nucl. Instr. and Meth., 1981, p. 18.

  2. Micromatter Co, Rt 1 Box 72B, Eastsound, Washington, 98245.

  3. J. M. HEAGNEY, J. S. HEAGNEY, Nucl. Instr. Methods 167 (1979) 137.

    Article  CAS  Google Scholar 

  4. I. V. MITCHELL, W. MAENHAUT, H. RAEMDONCK, F. BODART, Proc. 2nd Intern. Conf. Chem. Analysis using Charged Particle Accelerators, Namur, Belgium. Sept. 1981. To be published.

  5. G. I. JOHANSSEN, J. PALLON, K. G. MALMQVIST, K. R. AKSELSSON, Nucl. Instr. Methods, 181 (1981) 84.

    Google Scholar 

  6. W. K. CHU, J. W. MAYER, M. A. NICOLET, Backscattering Spectrometry, Academic Press, N. Y., 1978.

    Google Scholar 

  7. G. DECONNINCK, Introduction to Radioanalytical Physics, Elsevier Sci. Publ. Co., N. Y., 1978.

    Google Scholar 

  8. D. W. MINGAY, W. D. JONKER, B. J. SMITH, Atomic Energy Board, PEL Report 259 ISBN-0-86960-674-3, 1978.

  9. D. W. MINGAY, E. BARNARD, Nucl. Instr. Methods, 157 (1978) 537.

    Article  CAS  Google Scholar 

  10. S. MATTESON, M. A. NICOLET, Nucl. Instr. Methods, 160 (1979) 301.

    Article  CAS  Google Scholar 

  11. Brookhaven Instrument Corp., Model 1000C and ORTEC Model 439.

  12. J. L’ECUYER, J. A. DAVIES, N. NATSUNAMI, Nucl. Instr. Methods, 160 (1979) 337.

    Article  CAS  Google Scholar 

  13. I. V. MITCHELL, private communication.

  14. J. M. HEAGNEY, private communication.

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Mingay, D.W. Calibration of Micromatter Co. standards used for the calibration of PIXE analysis systems. J. Radioanal. Chem. 78, 127–135 (1983). https://doi.org/10.1007/BF02519757

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02519757

Keywords

Navigation