Abstract
Weekly, consecutive primary coolant samples from a boiling water reactor have been analyzed for239, 240Pu,238Pu+241Am,242Cm and244Cm for about two years, and for238Pu,241Pu and241Am for one year. Concentration ranges are reported. Samples were prepared for counting either directly by evaporation or by chemical separation on BioRad AG 1×4 resin and subsequent electrolysis, and were counted in 20 cm dia Frish grid ionization chambers. Procedures are described. For most actinide nuclides, activity ratios in primary coolant were found to be different from those in worldwide fallout, thus allowing an identification of origin in the case, that actinides should be detected in the vicinity of a nuclear power station.
Similar content being viewed by others
References
Th. TELFORD (Ed.), Water Chemistry of Nuclear Reactor Systems, British Nuclear Energy Society, London, 1978.
K. H. NEEB, H. NEIDL, H. STÖCKERT, Siemens Forsch.-u. Entwickl.-Ber., 1 (1972) 350.
H. HÖTZL, R. WINKLER, Nucl. Instr. Meth., 150 (1978) 177.
N. A. TALVITIE, Anal. Chem., 43 (1971) 1827.
H. HÖTZL, G. ROSNER, R. WINKLER, German Report GSF-S 412, 1976.
H. HÖTZL, R. WINKLER, German Report GSF-S 529, 1978.
E. HOLM, R. B. R. PERSSON, Rad. Environm. Biophys., 15 (1978) 261.
C. W. THOMAS, R. W. PERKINS, U.S. Report BNWL-1881, 1974.
G. ROSNER, German Report GSF-S 596, 1979.
E. P. HARDY, P. W. KREY, H. L. VOLCHOK, Nature (London), 241 (1973) 444.
P. W. KREY, E. P. HARDY, C. PACHUCKI, F. ROURKE, J. COLUZZA, W. K. BENSON, Proceedings of the USERDA-IAEA Symposium on Transuranium nuclides in the Environment, San Francisco, 1975, p. 671.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Rosner, G. Measurements of actinide nuclides in water samples from the primary circuit of a nuclear power plant. J. Radioanal. Chem. 64, 55–64 (1981). https://doi.org/10.1007/BF02518341
Received:
Issue Date: