Calculation and study of 14 MeV neutron attenuation coefficients in a double axis rotational system

  • A. G. Elayi
Article

Abstract

The neutron attenuation coefficient is determined in a double axis rotational system. The difference between a fixed system and a double axis rotational system is shown and curves for the neutron attenuation coefficient for the last case are drawn. The attenuated flux inside the sample is also drawn.

Keywords

Neutron Source Neutron Generator Fixed System Neutron Attenuation Space Coordinate System 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    A. G. ELAYI, Proc. Conf. Computers in Activation Analysis and Gamma-Ray Spectroscopy, US-DOE, Symposium series, 49, CONF-780421.Google Scholar
  2. 2.
    A. G. ELAYI, J. Radioanal. Chem., 52 (1979) 427.Google Scholar