Colonoscopy aided by magnetic 3D imaging: assessing the routine use of a stiffening sigmoid overtube to speed up the procedure

  • Published:
Medical & Biological Engineering & Computing Aims and scope Submit manuscript

Abstract

There are not enough trained colonoscopists to cope with the present recommended number of examinations required for diagnostic and surveillance purposes. If colorectal cancer screening is to be introduced, endoscopic examination of the large bowel needs to be easier to learn and significantly quicker to carry out. The ‘Bladen system’, first described in 1993, is a non-radiological method of visualising the path of the endoscope, using magnetic drive coils under the patient and a chain of sensors along the biopsy channel of the instrument. In 1998, results were published using a novel computer graphics system (the RMR system), in which a much more realistic image of the endoscope could be produced using the stored positional data from the Bladen system. The RMR system has been further refined to allow, for the first time ever, accurate measurement of the effect of the passage of a colonoscope along the bowel on the lengths of different segments of the large intestine. The results obtained in 232 patients undergoing colonoscopy are analysed. In 77 of the patients, a stiffening overtube is used to splint the sigmoid colon once the endoscope is at or beyond the splenic flexure. The mean time taken to pass the colonoscope across the transverse colon is significantly shorter (p<0.001) when an overtube is used, despite it resulting in significant lengthening of the transverse colon. The routine use of a stiffening overtube can be expected to reduce the total procedure time by between 10 and 20%.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Bartel, J., Hinojosa, T., Shah, N. (1995): ‘Colonoscopic length and procedure efficacy’,J. Clin. Gastroenterol.,21, pp. 30–32

    Article  Google Scholar 

  • Bell, G. D., Saunders, B., Williams, C. B., Pitt, R., andBladen, J. (1996): ‘Measurement of insertion depth during flexible sigmoidoscopy (FS) or colonoscopy by electromagnetic imaging (EMI): implications for colorectal cancer screening programmes’,Gut,39, (Suppl. 1: A26), (Abstract)

    Google Scholar 

  • Bladen, J. S., Anderson, A. P., Bell, G. D., Rameh, B., andEvans, B. (1993): ‘Non-radiological technique for three dimensional imaging of intestinal endoscopes’,Lancet,341, pp. 719–722

    Article  Google Scholar 

  • Endoscopy Section Committee of the British Society of Gastroenterology (1987): ‘Future requirements for colonoscopy in Britain’,Gut,28, pp. 772–775

    Article  Google Scholar 

  • Hunt, R. H. (1981): ‘Colonoscopy intubation techniques with fluoroscopy-8.4.2 The sigmoid splint/stiffening sleeve’,inHunt, R. H. andWaye, J. D. (Eds.): ‘Colonoscopy techniques, clinical practice and colour atlas’ (Chapman and Hall Ltd, London ISBN 0 412 22710 X) chap. 8, pp. 128–130

    Google Scholar 

  • Khullar, S. K., andDiSario, J. A. (1997): ‘Colon cancer screening. Sigmoidoscopy or colonoscopy?’inRex, D. K. (ed.): ‘Gastrointestinal endoscopy clinics of North America. Evolving issues in colon endoscopy’ Vol. 7, No. 3, pp. 365–386

  • Lieberman, D. A. (1995): ‘Cost-effectiveness model for colon cancer screening’,Gastroenterology,109, pp. 1781–1790

    Article  Google Scholar 

  • Mosse, C. A., Mills, T. N., Bell, G. D., andSwain, C. P. (1998): ‘Device for measuring the forces exerted on the shaft of an endoscope during colonoscopy’,Med. Biol. Eng. Comput.,36, pp. 186–190

    Article  Google Scholar 

  • Office of Population Censuses and Surveys (1991): ‘Mortality statistics: cause 1989, (HMSO, London) (Series DH2, no. 16)

    Google Scholar 

  • Parry, B. R., andWilliams, S. M. (1991): ‘Competency and the colonoscopist: A learning curve’,Aust. NZ J. Surg.,61, pp. 419–422

    Article  Google Scholar 

  • Rowland, R. S., andBell, G. D. (1998): ‘Non-radiological technique for 3D imaging of intestinal endoscopes: computerised graphical 3D representation of endoscope and skeleton’,Med. Biol. Eng. Comput.,36, pp. 285–290

    Article  Google Scholar 

  • Rowland, R. S., Bell, G. D., Dogramadzi, S., andAllen, C. (1999): ‘Validation of a 3-D method of accurately measuring the insertion depth of different anatomical sections of the colon during flexible endoscopy’,Gut,44, (suppl 1), p. A22

    Google Scholar 

  • Saunders, B. P., Bladen, J. S., Williams, C. B., andBell, G. D. (1995): ‘First clinical results with a real-time, electronic imager as an aid to colonoscopy’,Gut,36, pp. 913–917

    Article  Google Scholar 

  • Verne, J. E. C. W., Aubrey, R., Love, S. B., Talbot, I. C., andNorthover, J. M. A. (1998): ‘Population based randomised study of uptake and yield of screening by flexible sigmoidoscopy compared with screening by faecal occult blood testing’,Br. Med. J.,317, pp. 182–185.

    Google Scholar 

  • Williams, C. B. (1996): ‘Colonoscopy and flexible sigmoidoscopy— The stiffening or ‘overtube’,in, ‘Practical gastrointestinal endoscopy, 4th edn.’Cotton, P. B., andWilliams, C. B. (Eds.): (Blackwell Science Ltd, Oxford, ISBN 0-86542-851-4) chap. 9, pp. 246–247

    Google Scholar 

  • Williams, C. B., Saunders, B. P., Bell, G. D., Bladen, J. S., Gillies, D. F., andGuy, C. M. (1997): ‘Real-time magnetic three-dimensional imaging of flexible endoscopy’,inRex, D. K. (Ed.): ‘Gastrointestinal endoscopy clinics of North America. Evolving issues in colon endoscopy’, Vol. 7, No. 3, pp. 469–476

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to G. D. Bell.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Bell, G.D., Rowland, R.S., Rutter, M. et al. Colonoscopy aided by magnetic 3D imaging: assessing the routine use of a stiffening sigmoid overtube to speed up the procedure. Med. Biol. Eng. Comput. 37, 605–611 (1999). https://doi.org/10.1007/BF02513355

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02513355

Keywords

Navigation