Study of catheter designs and drug mixing processes using 2D steady numerical simulations

  • R. Mongrain
  • K. Kandarpa
  • A. Garon
  • O. F. Bertrand
  • M. Bertrand
Fluid Flow

Abstract

The effectiveness of substance delivery through catheters is an important issue in interventional radiology, especially for infusion therapies where the pharmacokinetic advantage of local intra-arterial drug administration has been firmly established. In principle, the procedure is used to provide appropriate local concentrations while maintaining low systemic values so as to minimise the global effect and toxicity of the intervention. However, poor drug mixing may produce excessive local concentrations potentially damaging for the surrounding tissues and may lead to unsuccessful therapies. These phenomena have been observed in the infusion therapies of liver cancers through the hepatic artery and with brain tumour therapies through the carotid artery. Many aspects of the drug delivery methodology have been explored in order to determine the infusion conditions that would provide optimal mixing: the catheter tip design is considered one of the most important characteristics to be investigated for this purpose. Interestingly, it turns out that angiographic procedures could also benefit from this, because better mixing properties are associated with designs that provide potentially less harmful flow conditions such as jets, whipping and recoil of the catheter on the vascular wall. A 2D steady numerical model is proposed, to simulate the main physical processes occurring during catheter substance infusion: blood dynamics is taken into account with the Navier-Stokes equations and substance dispersion by the flowing blood with the advection-diffusion equation. The model is used to evaluate mixing properties of certain catheter designs in different flow conditions. In particular, two types of side hole catheter are compared in the context of water bath injection and in the context of vessel injection. The simulations suggest that the improved mixng reported with water bath experiments would not be maintained in the clinical context of arterial circulation.

Keywords

Catheter design Drug mixing Infusion therapies Navier-Stokes and advection-diffusion equations 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Barth, K. H., Lutz, R. J., Kremers, P. W., andMiller, D. L. (1988): ‘Mixing problems of low hepatic artery infusion improvement with small caliber double lumen balloon catheters’,Invest. Radiol.,23, pp. 519–523CrossRefGoogle Scholar
  2. Buecker, A., Schmitz-Rode, T., Vorweck, D., andGuenther, R. W. (1995): ‘In-vivo comparison of two rheolytic thrombectomy systems’,Radiological Soc. N. Am.,197(P)Suppl. Radiol., p. 381Google Scholar
  3. Chen, H.-S. G. andGross, J. F. (1980): ‘Intra-arterial infusion of anticancer drugs: theoretic aspects of drug delivery and review of responses’,Cancer Treatment Rep.,64, (1), pp. 31–40Google Scholar
  4. Drasler, W. J., Jenson, M. L., Wilson, G. J., Thielen, J. M., Protonotarios, E. I., Dutcher, R. G., andPossis, Z. C. (1992): ‘Rheolytic catheter for percutaneous removal of thrombus’,Radiology,182, pp. 263–267Google Scholar
  5. Fluent (1992): ‘V.4.11, User Manuals’, Fluent Inc., Lebanon, New-Hampshire, USAGoogle Scholar
  6. Forstall, W. andGaylord, E. W. (1955): ‘Momentum and mass transfer in a submerged water jet’,J. Appl. Mech., pp. 161–164Google Scholar
  7. Froelich, J., Barth, K. H., Lutz, R. J., Lossef, S. V. andLindisch, D. (1992): ‘Injection characteristics and downstream contrast material distribution of Flush aortography catheters: in vitro study’,J. Vasc. Interventional Radiol., pp. 713–718Google Scholar
  8. Fung, Y.-C. (1990): ‘Biomechanics: motion, flow, stress and growth’ (Springer-Verlag)Google Scholar
  9. Hansen, E. C., Hawkins, M. C., Hawkins, I. F., Akins, W. E., Miles, S. G., andCollela, J. P. (1989): ‘New high-flow “Cloud” catheter for safer delivery of contrast material’,Cardiovasc. Radiol.,173, pp. 461–464Google Scholar
  10. Hinze, J. O. (1975): ‘Turbulence’ (New York, McGraw-Hill) pp 534–536Google Scholar
  11. Krovetz, J. L., Fairchild, B. T., Hardin, S., andMitchell, B. (1966): ‘An analysis of factors determining delivery rates of liquids through cardiac catheters’,Radiology,86, pp. 123–131Google Scholar
  12. Lutz, R. J., Dedrick, R. L., Boretos, J. W., Oldfield, E. H., Blacklock, J. B., andDoppman, J. L. (1986): ‘Mixing studies during intracarotid artery infusions in an in vitro model’,J. Neurosurg.,64, pp. 277–283CrossRefGoogle Scholar
  13. Lutz, R. J., andMiller, D. L. (1988): ‘Mixing studies during hepatic artery infusion in an in vitro model’,Cancer,62, (6), pp. 1066–1073CrossRefGoogle Scholar
  14. Mikhail, S. (1960): ‘Mixing of coaxial streams inside a closed conduit’,J. Mech. Eng. Sci.,2, (1), pp. 59–68CrossRefGoogle Scholar
  15. Mongrain, R., Bertrand, M., Garon, A., andToroussian, V. (1994): ‘Optical flow methods in angiography: a comparative study using simulated image sequences’,Innovation Technol. Biol. Med.,15, pp. 351–373Google Scholar
  16. Shanebrook, J. R., Tillotson, K. B., andWeick, B. L. (1992): ‘Vortex mixing catheter’,Med. Biol. Eng. Comput.,30, pp. 123–124CrossRefGoogle Scholar

Copyright information

© IFMBE 1999

Authors and Affiliations

  • R. Mongrain
    • 1
    • 2
  • K. Kandarpa
    • 1
  • A. Garon
    • 3
  • O. F. Bertrand
    • 2
  • M. Bertrand
    • 4
  1. 1.Harvard Medical School, Interventional Radiology DepartmentBrigham & Women's HospitalBostonUSA
  2. 2.Institut de Cardiologie de MontréalUniversité de Montréal, Biomedical Engineering DepartmentMontréalCanada
  3. 3.Mechanical Engineering Department, Ecole PolytechniqueUniversité de MontréalEdouard-MonpetitCanada
  4. 4.Biomedical Engineering Department, Ecole PolytechniqueUniversité de MontréalEdouard-MonpetitCanada

Personalised recommendations