, Volume 42, Issue 12, pp 985–989 | Cite as

Linear transformer driver with a 750-kA current and A 400-ns current risetime

  • A. A. Kim
  • B. M. Kovalchuk
  • E. V. Kumpyak
  • N. V. Tsoy
Article

Abstract

The paper describes the design and reports the results of tests of a linear transformer driver with the following parameters: stored energy 14 kJ, output voltage 90 kV, current amplitude in the secondary winding 750 kA, and current risetime to its peak ∼430 ns. The driver can be employed as the main generator unit powering a load of the Z-pinch type as well as in high-current charged-particle accelerators.

Keywords

Charge Voltage Load Voltage Power Amplification Total Radiation Energy Bushing Insulator 