Abstract
A new proton therapy facility for the treatment of deep-seated tumours is being assembled. The proton beam will be applied to the patient under computer control, using dynamic scanning of a focused proton pencil beam to produce a complete three-dimensional conformation of the dose to the target volume. The beam will be applied to the supine patient using a compact isocentric gantry for protons. By combining the scanning of the beam with the beam optics and by mounting the patient couch eccentrically on the gantry, the diameter of the rotating structure can be reduced to 4 m, which is the smallest diameter designed so far for a proton gantry. The paper describes the project especially from the point of view of the optics of the beam transport system of the gantry, including the beam line used to inject the beam into the gantry.
Similar content being viewed by others
References
Archambeau, J. O., Bennet, G. W., Levine, G. S., Cowen, R., andAkanumu, A. (1974): ‘Proton radiation therapy,’Radiol,110, pp. 445–457
Blattmann, H. (1992): ‘Beam delivery system for charged particles,’Radiat. Environ. Biophys.,31, pp. 219–231
Brahme, A., Källman, P., andLind, B. K. (1989): ‘Optimization of proton and heavy ion therapy using an adaptive inversion algorithm,’Radiother. Oncol.,15, pp. 189–197
Brown, K. L., Carey, D. C., Iselin, C., andRothacker, F. (1993): ‘Transport a computer program for designing charged particle beam transport systems’, CERN Yellow Report 73-16, CERN, Geneva, Switzerland
Koehler, A. M., Schneider, R. J., andSisterson, J. M. (1975): ‘Range modulators for protons and heavy ions,’NIM,131, pp. 437–440
Koehler, A. M., Schneider, R. J., andSisterson, J. M. (1977): ‘Flattening of proton dose distributions for large-field radiotherapy,’Med. Phys.,4, pp. 297–301.
Kowalsky, S., andEnge, H. A. (1987): ‘RAYTRACE,’ Laboratory for Nuclear Science & Department of Physics, Massachusetts Institute of Technology, Cambridge, Massachusetts, 02139 USA
Pedroni, E., Blattmann, H., Böhringer, T., Coray, A., Lin, S., Scheib, S., andShneider, U. (1992a): ‘Voxel scanning for proton therapy’ Proc. NIRS Int. Workshop on Heavy Charged Particle Therapy and Related Subjects.Itano, A., andKanai, T. (Eds.). National Institute of Radiological Sciences, Chiba, July 1991, NIRS-M-81
Pedroni, E. (1992b): ‘Accelerators for charged particle therapy: performance criteria from the user point of view.’ Proc. 13th Int. Conf. on Cyclotrons and their Applications,Dutto, G., andCraddock, M. K. (Eds.) (World Scientific, Vancouver, July 1992)
Pedroni, E., Bacher, R., Blattmann, H., Böhringner, T., Coray, A., Lomax, A., Lin, S., Munkel, G., Scheib, S., Schneider, U., andTourovsky, A. (1992c). ‘Status reports,PSI Life Sciences Newsletters, 1989/90, 1991 and 1992, Paul Scherrer Institute, Würenlingen and Villigen
Slater, J. M., Miller, D. W., andArchambeau, J. O. (1988): ‘Development of a hospital-based proton beam treatment center,’Int. J. Radiat. Oncol. Biol. Phys.,14, pp. 761–775
Suit, H., andUrie, M. (1992): ‘Proton beams in clinical radiation therapy,’Principles Pract. Oncol.,6, pp. 1–15
Tsuji, H., Tsuji, H., Inada, T., Maruhashi, A., Hayakawa, Y., Takada, Y., Tada, J., Fukumoto, S., Tatuzaki, H., Ohara, K., andKitagawa, T. (1993): ‘Clinical results of fractionated proton therapy,’Int. J. Radiat. Oncol. Biol. Phys.,25, pp. 49–60
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Pedroni, E., Enge, H. Beam optics design of compact gantry for proton therapy. Med. Biol. Eng. Comput. 33, 271–277 (1995). https://doi.org/10.1007/BF02510499
Received: