, Volume 56, Issue 1, pp S91–S94 | Cite as

Application of pseudo-reversed-phase systems to the purification and isolation of biologically active taxoids from plant material

  • M. L. Hajnos
  • K. Glowniak
  • M. Waksmundzka-Hajnos
  • S. Piasecka
Originals Column Liquid Chromatography

Summary

Silica and aqueous methanolic mobile phases have been optimized for the purification of crude yew extracts. From the recoveries measured for 10-deacetylbaccatin Ill and paclitaxel it was found that 20% methanol in water elutes all taxoids from the adsorbent and that non-polar materials remain in the starting band; this enables preparation of the samples before HPLC analysis. Partial separation of the taxoid fraction was achieved by elution with pure water then 6:4 methanol-water. Such systems on a large scale can be used for preparative separation of taxoids. Partially separated fractions are re-chromatographed in a normal-phase system consisting of silica with a non-aqueous mobile phase. This procedure enables isolation of 10-deacetylbaccatin Ill from the fraction.

Key Words

Column liquid chromatography Taxoids Silica with aqueous mobile phases Purification Isolation DrylabG software 

References

  1. [1]
    Wheeler, N.C.; Jech, K.; Masters, S.; Brobst, S.W.; Alvarado, A.B.; Hoover, A.J.; Snader, K.M.J. Nat. Prod. 1992,55, 432–440.CrossRefGoogle Scholar
  2. [2]
    Hezari, M.; Croteau, R.Planta Medica 1997,63, 291–302.Google Scholar
  3. [3]
    Glowniak, K.; Mroczek, T.J. Liq. Chromatogr. 1999,22, 2483–2502.CrossRefGoogle Scholar
  4. [4]
    Glowniak, K.; Wawrzynowicz, T.; Hajnos, M.; Mroczek, T.J. Planar Chromatogr. 1999,12, 328–335.Google Scholar
  5. [5]
    Theodoridis, G.; de Jong, C.F.; Laskaris, G.; Verpoorte, R.Chromatographia 1998,47, 1–10.CrossRefGoogle Scholar
  6. [6]
    Verstraeten, V.; De Keukeleire, D.Phytother. Res. 1996,10, 147–149.Google Scholar
  7. [7]
    Hajnos, M.L.; Glowniak, K.; Zobel, A.Phytomedicine 2001,8, 139–143.CrossRefGoogle Scholar
  8. [8]
    Hajnos, M.L.; Glowniak, K.; Waksmundzka-Hajnos, M.; Kogut, P.J. Planar Chromatogr. 2001,14, 119–125.Google Scholar
  9. [9]
    Jane, J.J. Chromatogr. 1975,111, 227.CrossRefGoogle Scholar
  10. [10]
    Brugman, W.J.Th.; Heemstra, S.; Kraak, J.C.Chromatographia 1982,15, 282.CrossRefGoogle Scholar
  11. [11]
    Crommen, J.J. Chromatogr. 1979,186, 705.CrossRefGoogle Scholar
  12. [12]
    Svendsen, H.; Greibokk, T.J. Chromatogr. 1981,212, 153.CrossRefGoogle Scholar
  13. [13]
    Wall, R.A.J. Chromatogr. 1980,194, 353.CrossRefGoogle Scholar
  14. [14]
    Golkiewicz, W.; Kuczynski, J.; Markowski, W.; Jusiak, L.J. Chromatogr. 1994,686, 85–91.CrossRefGoogle Scholar
  15. [15]
    Golkiewicz, W.; Gadzikowska, M.Chromatographia 1999,50, 52–56.CrossRefGoogle Scholar
  16. [16]
    Cox, G.B.; Stout, R.W.J. Chromatogr. 1987,384, 315.CrossRefGoogle Scholar
  17. [17]
    Dolan, J.W.; Lommen, D.C.; Snyder, L.R.J. chromatogr.,1989,485, 91.CrossRefGoogle Scholar
  18. [18]
    Snyder, L.R.; Dolan, J.W.Drylab G Instruction Manual, LC Resources, Lafayette, CA,1987.Google Scholar

Copyright information

© Friedr. Vieweg & Sohn Verlagsgesellschaft mbH 2002

Authors and Affiliations

  • M. L. Hajnos
    • 1
  • K. Glowniak
    • 1
  • M. Waksmundzka-Hajnos
    • 2
  • S. Piasecka
    • 1
  1. 1.Department of PharmacognosyMedical UniversityLublinPoland
  2. 2.Department of Inorganic and Analytical ChemistryMedical UniversityLublinPoland

Personalised recommendations