Summary
High resolution SFC separations of polysiloxanes using standard bore and 2 mm ID packed columns with pressure and density programming of pure carbon dioxide are demonstrated. Independent control of flow and pressure allowed enhanced resolution, particularly at higher molecular weights, over previous separations. More than 150 individual homologs of dimethylsiloxanes were at least partially resolved, allowing differentiation of molecular weight to over 11,000. Pure carbon dioxide appeared to be capable of eluting molecular weights up to an estimated 25,000.
The maximum molecular weight eluted was further extended by the addition of hexane to carbon dioxide. Detection was performed using both the FID (where possible) and UV at 191 nm. Use of the UV detector eliminated the need for a fixed restrictor required by the FID, which simplified routine use.
Similar content being viewed by others
References
Fjeldsted, J.C.; Lee, M.L.Anal. Chem. 1984,56, 619A-624A.
Pentoney, S.L.; et al.J. Chromatogr. Sci. 1987,25, 93.
Hill, Jr. H.H. in “SFC Applications, 1988 Workshop on Supercritical Fluid Chromatography”, compiled by: K.E. Markides, and M.L. Lee, Brigham Young Press,1988, p. 256.
Huang, E.C.; Lee, M.L. in “SFC Applications, 1988 Workshop on Supercritical Fluid Chromatography”, compiled by: Markides, K.E.; Lee, M.L., Brigham Young Press,1988, p. 261.
Hill, Jr. H.H. in “SFC Applications, 1989 Workshop on Supercritical Fluid Chromatography”, compiled by: Markides, K.E.; Lee, M.L. Brigham Young Press,1989, p. 328–331.
Chester, T.L.; Burkes, L.J.; Delaney, T.E.; Innis, D.P.; Owens, D.G.; Pinkston, J.D. in “Supercritical Fluid Extraction and Chromatography-Techniques and Applications”, Carpentier, B.A.; Sevenants, M. Eds. ACS Symposium Series, American Chemical Society,1988, p. 144.
Later, D.W.; Cambell, E.R.; Richter, B.E.J. High Resolut Chromatogr. Chromatogr. Commun. 1988,11, 65.
Fujimoto, C.; Hirata, Y.; Jinno, K.J. Chromatogr. 1985,332, 47.
Jinno, K.Chromatographia 1987,23, 55.
Hill, H.H.; Morrissey, M. in “Modern Supercritical Fluid Chromatography”, C.M. White, Ed., Huethig, Heidelberg,1988, p. 95.
Knowles, D.E.; Nixon, L.; Cambell, E.R.; Later, D.W.; Richter, B.E.Fres. Z. Anal. Chem. 1988,330, 225.
Lee, M.L.; Xu, B.; Huang, E.C.; Djordjevic, N.M.; Chang, H.-C.K.; Markides, K.E.J. Microcol. Sep. 1989,1, 7.
Bartle, K.D.; Burke, M.P.; Clifford, A.A.; Davies, I.L.; Kithinji, J.P.; Raynor, M.W.; Shilstone, G.F.; Williams A.Eur. Chromatogr. News 1988,2(5), 12.
Suprex Corp.1986. Publication No. 8602-01,02.
Hirata, H.J. Chromatogr. 1984,315, 39.
Klesper, E.; Schmitz, F.J. Chromatogr. 1987,402, 1.
Takeuchi, T.Chromatographia 1988,25, 332.
Hirata, Y.; Nakata, F.; Horihata, H.J. High Resolut. Chromatogr. 1984,11, 81–84.
Shen, Y.; Huang, H.; Liu, X.; Wang, Q.; Zhou, L.,J. High Resolut. Chromatogr. 1994,17, 74.
Shen, Y.; Lee, M.L.Chromatographia 1997,45, 67–77.
Wu, N.; Yee, R.; Lee, M.L.Chromatographia 2001,53, 197.
Miszkiewicz, W.; Hreczuch, W.; Sobczynska, A.; Szymanowski, J.Chromatographia 2000,51, 95–100.
Okada, T.J. Chromatogr. 1992,609, 213.
Nozawa, A.; Ohnuma, T.J. Chromatogr. 1980,187, 261.
Berger, T.A.Chromatographia 2001,54, 783–788.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Berger, T.A., Todd, B.S. Packed column supercritical fluid chromatography of polysiloxanes using pure and hexane modified carbon dioxide with flame ionization and ultraviolet detection. Chromatographia 54, 771–775 (2001). https://doi.org/10.1007/BF02492497
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02492497