Summary
A sensitive, accurate and reproducible high performance liquid chromatographic (HPLC) procedure has been developed for the separation and analysis of lorazepam and related compounds. A 20-μL sample was separated by reversed-phase HPLC on a 150 mm ×4.6 mm, 5-μm particle, Wakosil column with 0.1m ammonium acetate (pH adjusted to 6.0 with acetic acid)-acetonitrile-methanol, 1:1:1 (v/v) as mobile phase.
Similar content being viewed by others
References
USP XXIII, United States Pharmacopoeial Convention, Rockville, MD,1995.
USP XXIII, Supplement VI, United States Pharmacopoeial Convention, Rockville, MD,1997.
Sane, R.T.; Nayak, V.G.; Bhate, V.R.; Joshi, M.D.; Purandre, S.M.Indian Drugs 1989,26(9), 497–499.
Kondo, T.; Buss, D.C.; Routlege, P.A.Ther. Drug. Monit. 1993,15(1), 35–38.
Ruczaj, D.; Kulinska, A.Chem. Anal. 1989,34(1), 97–101.
Walash, M.J.; Belal, F.; Metwally, M.E.; Hefawy, M.M.J. Pharm. Biomed. Anal. 1994,12(11), 1417–1423.
El-Brashy, A.; Aly, F.A.; Belal, F.Microchim. Acta 1993,110(1–3), 55–60.
Greenhow, E.J.; Ladipo, O.Fresenius' Z. Anal. Chem. 1985,321(5), 485–489.
British Pharmacopeia, The Pharmaceutical Press, London, UK,1998.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Orlovic, D., Radulovic, D., Ivanovic, D. et al. HPLC determination of lorazepam and lorazepam-related compounds in pharmaceutical formulations. Chromatographia 52, 732–734 (2000). https://doi.org/10.1007/BF02490997