Skip to main content
Log in

Purity testing of organometallic catalysts by micro liquid chromatography-electron ionization mass spectrometry

  • Originals
  • Published:
Chromatographia Aims and scope Submit manuscript

Summary

A micro liquid chromatography-mass spectrometry system utilizing 100 μm i. d. packed capillary columns has been used for purity testing of organometallic catalysts. The total effluent, 1 μLmin−1 from the column, was introduced directly into the ion source of a bench-top quadrupole mass spectrometer and electron ionization mass spectra were acquired. In full scan mode a mass limit of detection of 10–15 ng was achieved for the organometallic compounds investigated. The catalysts dimethyl pentamethylcyclopentadienyl iridium dimethylsulphoxide (Cp*Ir(DMSO)Me2) and di(pentamethylcyclopentadienyl dichloro iridium) ((Cp*IrCl2)2) were purity tested and their electron ionization mass spectra recorded. Impurities present down to 1% of the main compound could be determined using large volume injection.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. A. Casoli, A. Mangia, G. Predieri, Chem. Rev.89, 407 (1989).

    Article  CAS  Google Scholar 

  2. P. Wang, H. K. Lee, J. Chromatogr. A789, 437 (1997).

    Article  CAS  Google Scholar 

  3. D. S. Nagra, L. Li, J. Chromatogr. A711, 235 (1995).

    Article  CAS  Google Scholar 

  4. W. M. A. Niessen, A. P. Tinke, J. Chromatogr. A703, 37 (1995).

    Article  CAS  Google Scholar 

  5. C. M. Whitehouse, R. N. Dreyer, M. Yamashita, J. Fenn, Anal. Chem.57, 675 (1985).

    Article  CAS  Google Scholar 

  6. E. C. Huang, T. Wachs, J. J. Comboy, J. D. Henion, Anal. Chem.62, 713 (1990).

    Google Scholar 

  7. A. Capiello, G. Faminglini, J. Am Soc Mass Spectrom.9, 993 (1998).

    Article  Google Scholar 

  8. T. Takeuchi, D. Ishii, A. Saito, T. Ohki, HRC & CC5, 91 (1982).

    CAS  Google Scholar 

  9. A. V. de Miguel, M. Gomez, K. Isobe, B. F. Taylor, B. E. Mann, P. M. Maitilis. Organometallics,2, 1724 (1983).

    Article  Google Scholar 

  10. R. G. Ball, W. A. G. Graham, J. K. Hoyano, A. D. McMaster, B. M. Mattson, S. T. Michel, D. M. Heinekey, Inorg. Chem.29, 2023 (1990).

    Article  CAS  Google Scholar 

  11. P. M. Maitlis, K. Isobe, A. Vázquez de Miguel, A. Nutton, J. Chem. Soc. Dalton Trans.,I, 929 (1984).

    Google Scholar 

  12. R. Trones, A. Iveland, T. Greibrokk, J. Microcol. Sep.7, 505 (1995).

    Article  CAS  Google Scholar 

  13. D. Bruch, G. Bünau, W. Schindler, H. Kisch, Int. J. Mass Spectrom. Ion Processes148, 105 (1995).

    Article  CAS  Google Scholar 

  14. M. J. Mills, J. Maltas, J. Lough, J. Chromatogr. A759, 1 (1997).

    Article  CAS  Google Scholar 

  15. M. Tilset, Unpublished results.

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Bruheim, I., Fooladi, E.C., Lundanes, E. et al. Purity testing of organometallic catalysts by micro liquid chromatography-electron ionization mass spectrometry. Chromatographia 50, 479–484 (1999). https://doi.org/10.1007/BF02490745

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02490745

Key Words

Navigation