Determination of the endocrine disrupter bisphenol—A in the blood of uremia patients treated by dialysis

  • H. Shintani
Short Communications Column Liquid Chromatography

Summary

Automated solid-phase extraction (SPE) then high-performance liquid chromatography have been studied for determination of the endocrine disrupter bisphenol-A (BPA) in blood. Electrochemical detection was used for selective and sensitive detection of BPA. Determination of BPA in the blood of uremia patients treated by dialysis has not yet been reported. Acidified blood and acidified SPE eluent were used to suppress the ionization of BPA and thus retain the compound on a C18 column. Because artificial dialysis can be performed for periods longer than 20 years, for reasons of safety the amount of BPA migrating from the artificial dialyzer into the blood of a uremia patient was compared for different sterilization methods and for different artificial dialyzers manufactured from different materials.

Key Words

Column liquid chromatography Solid-phase extraction Dialysis Bisphenol-A 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. [1]
    Lamb, J.Environ. Health Perspect. 1997,105 (Suppl. 1), 273–274.Google Scholar
  2. [2]
    Krishnan, V.A.Endocrinology 1993,132, 2279–2286.CrossRefGoogle Scholar
  3. [3]
    Milligan, R.S.Environ. Health Perspect.1998,106, 23–26.Google Scholar
  4. [4]
    Ashby, J.Environ. Health Perspect. 1998,106, 719–720.Google Scholar
  5. [5]
    Nagel, S.C.Environ. Health Perspect.1997,105, 70–76.Google Scholar
  6. [6]
    vom Saal, F.Toxicol. Indust. Health 1998,14, 239–260.Google Scholar
  7. [7]
    Cagen, S.Z.Toxicol. Sci. 1999,50, 36–44.CrossRefGoogle Scholar
  8. [8]
    Crews, D.; Skipper, J.K.Q. Rev. Biol. 2000,75, 243–260.CrossRefGoogle Scholar
  9. [9]
    Shintani, H.; Tsuchiya, T.J. Anal. Toxicol. 1993,17, 73–78.Google Scholar
  10. [10]
    Shintani, H.J. Liq. Chromatogr. 1995,18, 613–626.Google Scholar
  11. [11]
    Shintani, H.J. Liq. Chromatogr. 1998,21, 2297–2312.Google Scholar
  12. [12]
    Shintani, H.J. Lip. Chromatogr. 1992,15, 1315–1335.Google Scholar
  13. [13]
    Shintani, H. InAdsorption and its Application in Industry and Environmental Protection: Dabrowski, A., Ed, Elsevier Science, Amsterdam,1998.Google Scholar
  14. [14]
    Shintani, H.Fresenius J. Anal. Chem. 1989,333, 637–640.CrossRefGoogle Scholar
  15. [15]
    ISO/TO 194,Biological Evaluation of Medical Devices.Google Scholar
  16. [16]
    Shintani, H.Biomed. Instrum. Technol. 1995,29, 513–519.Google Scholar
  17. [17]
    Shintani, H.Rad. Phys. Chem. 1995,46, 377–381.CrossRefGoogle Scholar

Copyright information

© Friedr. Vieweg & Sohn Verlagsgesellschaft mbH 2001

Authors and Affiliations

  • H. Shintani
    • 1
  1. 1.National Institute of Health SciencesTokyoJapan

Personalised recommendations