  • Original Article
  • Dialysis
  • Published:
Journal of Artificial Organs Aims and scope Submit manuscript

Abstract

Blood and dialysate flow patterns in hollow-fiber dialyzers are complicated, and hence the flow patterns and mass transfer are difficult to analyze theoretically. Consequently, dialyzers are usually developed by a trial-and-error method. We attempt to design dialyzers by computer simulation analysis in this work. Blood-side and dialysate-side flows were modeled using the Hagen-Poiseuille equation and the Blake-Kozeny equation, respectively. These flow patterns were evaluated as pressure drop and velocity distribution. The mass transfer rate was evaluated as solute clearance. Computed values of the pressure drops and clearance for urea and vitamin B12 were found to agree closely with those obtained experimentally. We evaluated the influences of the inner diameter of hollow fibers, module geometry, and void fraction on the pressure drop and clearance, and computer-aided design was performed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Sakai K. Technical determination of optimal dimensions of hollow fibre membranes for clinical dialysis. Nephrol Dial Transplant 1989;4(Suppl):73–77

    Google Scholar 

  2. Takesawa S, Terasawa M, Sakagami M, Kobayashi T, Hidai H, Sakai K. Nondestructive evaluation by X-ray computed tomography of dialysate flow patterns in capillary dialyzers. ASAIO J 1988;34:794–799

    CAS  Google Scholar 

  3. Bird RB, Stewart WE, Lightfoot EN. Transport phenomena. New York: Wiley, 1960:196–200

    Google Scholar 

  4. McAdams WH. Heat transmission, 3rd edn. New York: McGraw-Hill, 1954

    Google Scholar 

  5. Fukuda M, Hosoya N, Kanamori T, Sakai K, Nisikido J, Watanabe T, Fusimi F. Determination of optical fiber density of conventional and higher performance dialyzer. Artif Organs Today 1992;2:205–214

    Google Scholar 

  6. Ohmura T, Tasuguchi T, Nishikido J, Yamamoto T, Fushimi F, Nishida O, Sakai K. A new method of determining the solute permeability of hollow-fiber dialysis membranes by means of laser lights traveling along optic fibers. ASAIO J 1989;35:601–603

    CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Kiyotaka Sakai PhD.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Suzuki, Y., Kohori, F. & Sakai, K. Computer-aided design of hollow-fiber dialyzers. J Artif Organs 4, 326–330 (2001). https://doi.org/10.1007/BF02480026

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02480026

Key words

Navigation