On-line generation of a Joint Interval Histogram from slow rhythmic biological potentials

  • Published:
Medical and biological engineering Aims and scope Submit manuscript

Abstract

The use of the Joint Interval Histogram technique for rhythm analysis of slow biological potentials is described. This technique allows the investigator to recognize relationships between adjacent intervals in long runs of temporal data. The mechanization of this method of analysis through the design of a new circuit is described. The approach offers flexibility; a wide variety of data analysis applications can be handled utilizing the JIH technique.

Application of this system to data analysis problems in gastrointestinal physiology is discussed. The system is especially useful in recognition of waveforms whose rhythm is determined by a pacemaker potential. The nature of the biological oscillation may then be deduced by comparison with JIH's constructed from analog computer models. Interpretation of various JIH plot patterns is discussed in relation to the diagnosis of the presence or absence of pacemakers.

Sommaire

L'article décrit l'utilisation de la technique de l'histogramme de latence pour l'analyse des potentiels biologiques à rythme lent. Cette technique permet de mettre en évidence certaines relations entre des intervalles adjacents au cours de longues séquences de données. La mise en oeuvre de cette méthode est appuyée par la description d'un circuit de type nouveau.

Cette technique offre une grande souplesse d'application dans les differéntes analyses de données.

Les auteurs présentent l'application de ce système à l'analyse de données en physiologie gastrointestinale. Le système est particulièrement utile pour la reconnaissance des formes d'ondes dont le rythme est lié au potentiel d'un pacemaker. La nature des oscillations biologiques peut alors se déduire par comparaison avec un histogramme de latence engendré à partir d'un modèle analogique. L'interprétation des différentes formes d'histogrammes dépend de la présense ou de l'absence de Pacemaker.

Zusammenfassung

Die Verwendung des Verfahrens mit Verbund-Intervall-Histogrammen (VIH) zur Rhythmusanalyse langsamer biologischer Potentiale wird beschrieben. Das Verfahren ermöglicht, Beziehungen aufeinanderfolgender Intervalle bei langdauernden Zeitdaten zu erkennen. Die Mechanisierung dieser Analysemethode mit Hilfe einer neuen Schaltung wird beschrieben. Der Arbeitsvorgang bietet Flexibilität. Für das VIH-Analyseverfahren bietet sich ein weiter Anwendungsbereich.

Die Anwendung dieses Systems auf die Datenanlyse aus der Gastrointestinalphysiologie wird diskutiert. Das System ist besonders brauchbar zur Erkennung von Wellenformen, deren Rhythmus durch ein Schrittmacherpotential vorgegeben ist. Die Art der biologischen Oszillation kann dann aus dem Vergleich mit den VIH, welche von Analogrechnermodellen konstruiert wurden, abgeleitet werden. Die Beurteilung verschiedener VIH-Muster wird hinsichtlich der Diagnose der Gegenwart oder der Abwesenheit von Schrittmachern diskutiert.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Rodieck, R. S., Kiang, N.Y-S. andGerstein, G. L. (1962) Some quantitative methods for the study of spontaneous activity single neurons.Biophys. J. 2, 351–368.

    Article  Google Scholar 

  • Schulman, J. H. andThorsen, J. (1964) On-line analog generation of joint interval histogram.Rev. scient. Instrum. 35, 1314–1315.

    Article  Google Scholar 

  • Alvarez, W. C. andMahoney, L. J. (1922) Action currents in stomach and intestine.Am. J. Physiol. 58, 476–493.

    Google Scholar 

  • Bunker, C. E. andNelsen, T. S. (1964) Use of the electroenterogram to determine pacemaker activity of the small intestine.Surg. Forum. 15, 293–295.

    Google Scholar 

  • Van der Pol, B. andVan der Mark, J. (1928) The heartbeat considered as a relaxation oscillation.Phil. Mag., Suppl. 6, 763–775.

    Google Scholar 

  • Parzen, E. (1962)Modern Probability Theory and its Applications. Wiley, New York.

    MATH  Google Scholar 

  • Nelsen, T. S. andBecker, J. C. (1968) Simulation of the electrical and mechanical gradient of the small intestine.Am. J. Physiol. In press.

Download references

Author information

Authors and Affiliations

Authors

Additional information

Supported by U.S.P.H.S. Grant AM 08109

Rights and permissions

Reprints and permissions

About this article

Cite this article

Becker, J.C., Wallace, J. & Nelsen, T.S. On-line generation of a Joint Interval Histogram from slow rhythmic biological potentials. Med. & biol. Engng. 6, 415–423 (1968). https://doi.org/10.1007/BF02476064