Matériaux et Construction

, Volume 10, Issue 3, pp 153–158 | Cite as

Experimental investigations on the fatigue behaviour of cold-worked deformed bars

  • V. P. narayanaswamy
  • V. K. Gupta
  • J. N. Chhauda
  • A. Rajaraman
Article
  • 64 Downloads

Abstract

The importance of fatigue of reinforcing steel in reinforced concrete structural members is discussed. The mechanism of fatigue failure of reinforcing bars and the factors affecting it are explained. The details of an experimental investigation for the determination of the fatigue characteristics of cold-worked deformed bars embedded in concrete beams are described. The results of the fatigue tests are discussed and recommendations for design are given.

Keywords

Fatigue Fatigue Strength Fatigue Behaviour Fatigue Failure Concrete Beam 

Notation

As

area of reinforcing steel

N

number of cycles of repeated loading

Pmin

minimum load

Pmax

maximum load

S

range of stress

σcu

cube compressive strength of concrete

σmax

maximum stress in a stress cycle

σmean

mean stress

σmin

minimum stress in a stress cycle

σsu

ultimate strength of reinforcing steel

σsy

yield stress of reinforcing steel

Résumé

Les armatures à haute résistance et haute adhérence ont généralement une résistance à la fatigue faible due aux concentrations de contraintes causées par la présence des nervures. C'est un problème critique dans les constructions en béton armé telles que les ponts soumises à des à froid ont été menées au cours des trente dernières années. Cet article rend compte des résultats des recherches du Structural Engineering Research Centre, Roorkee, India, sur les caractéristiques de fatigue des barres à haute adhérence écrouies à froid produites en Inde.

Huit poutres de béton chacune armée d'une barre à haute adhérence de 25 mm de diamètre écrouie à froid— dénommée «Tiscon»—ont été soumises à des essais de charge répétée. Pour toutes les poutres, la contrainte minimale a été maintenue à 10% de la limite conventionnelle de proportionnalité de la barre, tandis que la contrainte maximale variait de 40 à 80% de cette limite. La fréquence de répétition de charge était de 480 cycles par minute. On a tracé la courbe du nombre de cycles à la rupture (N) fournie par les essais en fonction du niveau de contrainte (S). Il a été établi que le niveau de contrainte qui peut être maintenu pour 2 millions de cycles était de 2 450 kg/cm2. Pour le calcul des structures soumises à des charges répétées, on recommande une valeur de sécurité de 1 750 kg/cm2.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. [1]
    Dynamic studies of bridges on AASHO road test. Highway Research Board, Special Report No. 71, 1962.Google Scholar
  2. [2]
    ACI Committee 439,Uses and limitations of high strength steel reinforcement f y=60 ksi (42.2 kgf/mm 2). A.C.I. Journal, Proc., Vol. 70, No. 2, February 1973, pp. 77–104.Google Scholar
  3. [3]
    Roš M.The fundamentals of material technology and the problem of reinforced concrete from the point of view of future development of reinforced concrete construction (in German). E.M.P.A., Bericht (Zurich), No. 162, 1950.Google Scholar
  4. [4]
    Rehm G.Contribution to the problem of the fatigue strength of steel bars for concrete reinforcement (in German). Preliminary Publication, Sixth Congress (Stockholm), I.A.B.S.E., 1960, pp. 35–46.Google Scholar
  5. [5]
    Soretz S.Fatigue behaviour of high yield stress reinforcement. Concrete and Constructional Engineering, Vol. 60, No. 7, July 1965, pp. 272–280.Google Scholar
  6. [6]
    Wascheidt H.On the problem of fatigue strength of steel bars embedded in concrete (in German). Doctoral Thesis, Technical University of Aachen, Germany, 1965.Google Scholar
  7. [7]
    Yokomichi H., Fujita Y., Nishihori T.Fatigue test of reinforced concrete beams using deformed bars (in Japanese with English Summary). The Second Symposium on Deformed Bars, Japan Society of Civil Engineers, December 1965, pp. 183–190 and 233–235.Google Scholar
  8. [8]
    A.C.I. Committee 215.—Considerations for design concrete structures subjected to fatigue loading. A.C.I. Journal, Proc. Vol. 71, No. 3, March 1974, pp. 97–121.Google Scholar
  9. [9]
    I.S. 1786–1966.Specification for cold twisted steel bars for concrete reinforcement (Revised). Indian Standards Institution, New Delhi, October 1966.Google Scholar
  10. [10]
    Pfister J. F., Hognestad E.High strength bars as concrete reinforcement, Part 6, fatigue tests. Bulletin D 74, Portland Cement Association Research and Development Laboratories (U.S.A.), 1964.Google Scholar

Copyright information

© Secrétariat de Rédaction 1977

Authors and Affiliations

  • V. P. narayanaswamy
    • 1
  • V. K. Gupta
    • 1
  • J. N. Chhauda
    • 1
  • A. Rajaraman
    • 1
  1. 1.Structural Engineering Research CentreRoorkeeIndia

Personalised recommendations