Advertisement

Matériaux et Construction

, Volume 6, Issue 1, pp 53–56 | Cite as

Condensation in slabs of cellular plastics

  • I. Paljak
Article

Keywords

Thermal Conductivity Polystyrene Urethane Vapour Permeability Partial Vapour Pressure 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. [1]
    Levy M.M..—Moisture Vapour Transmission and Its Effect on Thermal efficiency of Foam Plastics. J. Cellular Plastics, Jan. 1966.Google Scholar
  2. [2]
    Mittasch H..—Abhängigkeit der Wärmeleitfähigkeit von Plastschäumen vom Feuchtigkeitsgehalt. Plase und Kautschuk Heft 4, 1969.Google Scholar
  3. [3]
    Jespersen H.B..—Fugtens indvirkning på nogle nyere typer varmeledningsmaterialer. Beretning fra Teknologisk Instituts varmetekniska afdelning, 1960.Google Scholar
  4. [4]
    Vos B.H..—Internal Condensation in Structures. Build. Sci. Vol. 3, 1969.Google Scholar
  5. [5]
    Tveit A..—Measurements of Moisture sorption and moisture permeability of porous materials. Rep. No 45 Natn. Build. Res. Inst., Oslo, 1966.Google Scholar
  6. [6]
    Lang D.L..—A quick thermal Conductivity Test on Insulating Materials. ASTM Bulletin, September 1956.Google Scholar

Copyright information

© Secrétariat de Rédaction 1973

Authors and Affiliations

  • I. Paljak
    • 1
  1. 1.National Swedish Institute for Materials TestingSweden

Personalised recommendations