Advertisement

A cardiotachometer with fast response

  • J. Czekajewski
  • P. A. Tove
Article

Abstract

A pulse-period or frequency meter with fast response to changes has been constructed, utilizing the principle of time measurement by alternate charging and voltage measurement of two capacitors. It has been applied to cardiotachometry. Previously published cardiotachometer circuits with fast response are briefly reviewed. The linearization of scale for frequency-measuring devices utilizing capacitor charging is discussed.

Keywords

Fast Response Input Pulse Frequency Scale Pulse Interval Capacitor Voltage 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Sommaire

Un appareil de mesure de fréquence d’une période pulsatoire, à réaction rapide, a été réalisé. Le principe consiste à mesurer le temps par des mesures alternative de la charge et de l’intensité de deux condensateurs. Ce principe a été appliqué à la cardiotachymétrie; un bref aperçu est donné sur les études antérieures traitant des circuits similaires. La linéarisation de l’échella utilisée dans les appareils de mesure de fréquence employant la charge d’un condensateur est discutée.

Zusammenfassung

Ein schnell reagierender Frequenzmesser für periodische Impulse wurde konstruiert, indem das Prinzip der Zeitmessung durch wechselnde Aufladung zweier Kondensatoren in Verbindung mit Spannungsmessung verwandt wurde. Es wurde auf die Herzfrequenzmessung angwandt. Über ähnliche früher veröffentlichte Schaltungen wird kurz berichtet. Die Linearisierung der Anzeige von frequenzmessenden Geräten, die die Aufladung von Kondensatoren benutzen, wird erläutert.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Andrew, A. M. andRoberts, T. M. D. (1954)Electron. Engng.,26, 469–474.Google Scholar
  2. Cornwall, J. B. andMelville, A. W. (1962)Electron. Engng.,34, 537–539.Google Scholar
  3. Mackay, R. S. (1963)Med. Electron. Biol. Engng.,1, 109–111.CrossRefGoogle Scholar
  4. MacNichol, E. F. andJacobs, J. A. H. Rev. Sci. Instrum.,26, 1176–1180.Google Scholar
  5. Manzotti, M. (1956)Electron. Engng.,28, 446–448.Google Scholar
  6. Melville, A. W. andCornwall, J. B. (1958)Electron. Engng.,30, 606–607.Google Scholar
  7. Sloman, G. andTyson, G. (1962)Electron. Engng.,34, 626–627.Google Scholar
  8. Tove, P. A. andCzekajewski, J. (1964)Electron. Engng.,36, 290–295.Google Scholar
  9. Wyatt, D. G. (1956)J. sci. Instrum.,33 440–444.CrossRefGoogle Scholar