Experimental tests on the shear behaviour of dowels connecting concrete slabs to stone masonry walls

  • Published:
Materials and Structures Aims and scope Submit manuscript

Abstract

An experimental investigation has been conducted on the behaviour of dowels used to connect concrete slabs to stone masonry walls in order to transfer horizontal shear forces. A technique for embedding the dowels in the stone block without injection of grouting material or resin has been developed. Special experimental equipment has been designed in order to allow the execution ofin situ load tests on representative ancient buildings. Monotonic loading tests have been carried out on eight specimens with the purpose of measuring both stone block displacement and dowel deformation

Resume

Dans ce travail nous avons mené une enquête expérimentale sur le comportement vis-à-vis de l’effort tranchant des connexions à goujon, utilisées dans le but de transmettre les actions horizontales (par ex. forces sismiques) entre une dalle en béton armé et une maçonnerie en pierre. La technique adoptée consiste dans l’ancrage des goujons dans la maçonnerie, réalisé au moyen d’un trou calibré dans la pierre, puis d’une insertion en force du goujon. Cette technique présente l’avantage de ne pas exiger des interventions onéreuses au niveau de la maçonnerie, susceptibles d’en réduire la résistance.

Nous avons préparé un appareillage spécifique permettant l’exécution d’expériencesin situ. Pour simplifier l’exécution, l’effet de la dalle en béton a été simulé à l’aide d’une plaque métallique conçue dans ce but. Nous avons donc effectué huit expériences sur la maçonnerie en pierre d’un vieux bâtiment. Durant chaque expérience, la charge subissait de faibles accroissements progressifs et, à chaque accroissement, on enregistrait aussi bien le déplacement relatif entre la plaque métallique et la maçonnerie que les déplacements (translation et rotation) du bloc auquel le goujon était fixé. La plupart des échantillons essayés ont atteint la rupture par cassure transversale du bloc due à des glissements entre la plaque métallique et la maçonnerie, variant entre 2 et 4 mm.

Après la rupture par cassure du bloc, on n’a pas relevé de brusques réductions de la capacité portante qui, au contraire, est restée constante ou a enregistré une légère augmentation avec l’accroissement du glissement. Nous avons par ailleurs déterminé la charge correspondant à la limite d’écoulement du goujon. En outre, dans les essais effectués, la translation du bloc constitue 20 à 30% du glissement global de la plaque par rapport à la maçonnerie.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Abbreviations

u 1,u 2 :

Perpendicular displacements of two points of the block at distancesx 1 andx 2 from the dowel, respectively

υ3 :

Displacement of the block in the direction of the load measured at a distancey 3 from the surface of the wall

δ:

Displacement of the block in the direction of the load

η:

Displacement due to dowel deformation

α:

Rotation of the stone block

s :

Slip between the steel flange and the masonry wall

F :

Transversal load

F y :

Transversal load at the beginning of yielding of the dowel

f ys :

Yield strength

ϕ:

Diameter of the dowel

l h :

Distance between two plastic hinges in the shank of the dowel

l m :

Distance between the steel flange and the stone surface

References

  1. Tomăzevič, M., ‘Some aspects of structural strengthening of historic buildings in urban and rural nuclei against earthquakes’,Euro. Earthquake Engng No. 1 (1989) 19–40.

    Google Scholar 

  2. Benedetti, D., “Reparation and strengthening of masonry buildings’, in ‘Costruzioni in Zona Sismica’ (Masson Italia Editore, Milan, 1981) pp. 327–398 (in Italian).

    Google Scholar 

  3. Hume, I., ‘Conservation engineering—an English Heritage view’, in Proceedings of STREMA (Structural Repair and Maintenance of Historical Buildings), Seville, 1991, pp. 3–12.

  4. Turnšek, V., Terčelj, S., Sheppard, P. and Tomaževič, M., ‘The seismic resistance of masonry walls and buildings’, in Proceedings of 6th European Conference on Earthquake Engineering, Dubrovnik, 1978, Vol. 3, pp. 255–262.

  5. Giuriani E. and Frangipane, A., ‘Theoretical and Experimental Analysis of a Wood-Concrete Composite Beam under Repeated Loads’, Technical Report (Department of Civil Engineering, Brescia, 1988) (in Italian).

    Google Scholar 

  6. Ronca, P., Gelfi, P. and Giuriani, E., ‘The behaviour of a wood-concrete composite beam under cyclic and long term loads’, in Proceedings of STREMA (Structural Repair and Maintenance of Historical Buildings), Seville, 1991, pp. 264–275.

  7. Turrini, G. and Piazza, M., ‘A stiffening technique of wood-beam floors’, in ‘Recuperare’ (PEG, Milan, 1983) Nos 5–7 (in Italian).

    Google Scholar 

  8. Castellani, A., Ruggeri, L., Boffi, G. and Cenzon, F., ‘Strengthening of masonry buildings: effectiveness of connections between floors and walls concerning the redistribution of horizontal forces’,Ingegneria Sismica Anno VI (No. 1) (1989) 49–61 (in Italian).

    Google Scholar 

  9. Sanders, H. P., ‘A case history—retrofit seismic strengthening of John Marshall High School with historic restoration objectives’ in Proceedings of 8th World Conference on Earthquake Engineering, San Francisco, 1984, pp. 617–624.

  10. Gelfi, P. and Giuriani, E., ‘Theoretical constitutive law for stud shear connector’, in ‘Studi e Ricerche, Corso di Perfezionamento per le Costruzioni in Cemento Armato F.lli Pesenti’, Vol. 9 (Politecnico di Milano, Italia, 1987) (in Italian).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Giuriani, E., Gattesco, N. & Del Piccolo, M. Experimental tests on the shear behaviour of dowels connecting concrete slabs to stone masonry walls. Materials and Structures 26, 293–301 (1993). https://doi.org/10.1007/BF02472951

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02472951

Keywords

Navigation