The slump loss characteristics of concrete containing different amounts of sulphonated melamine formaldehyde (SMF) admixed with two types of polymers were investigated. The addition of 2% polymer to SMF retarded the slump loss. The setting times although retarded were found to satisfy the requirements of the ASTM standards.

Addition of the polymer to a commercial superplasticizer formulation further extended its slump loss capability. The final setting times were within the limits specified by ASTM but the initial setting times were significantly higher than the specified ASTM limits.

The control of slump loss in the presence of polymer may be related to the retarding action on the formation of ettringite from the C3A+Gypsum reaction in cements.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Malhotra, V. M., ‘Superplasticizers: Their Effect on Fresh and Hardened Concrete’, CANMET Report 79-31. Energy, Mines & Resources, Ottawa, Canada, 1979, 23.

    Google Scholar 

  2. Collepardi, M., Corradi, M. and Valente, M., ‘Low Slump Loss Superplasticized Concrete. I. Influence of a Naphthalene—Sulfonated Polymer Based Superplasticizer on the Cement Hydration’,Trans. Res. Rec. (720) (1979) 7–12.

    Google Scholar 

  3. Perenchio, W. F., Whiting, D. A. and Kantro, D. L., ‘Water Reduction, Slump Loss and Entrained Air Void System as Influenced by Superplasticizers’, Proceedings of International Symposium on Superplasticizers in Concrete (CANMET, Department of Energy, Mines and Resources, Ottawa, 1978) Vol. 1, pp. 295–324.

  4. Mailvaganam, N. P., ‘Factors Influencing Slump Loss in Flouring Concrete’, Superplasticizers in Concrete, Amer. Conc. Inst. SP-62, 1979, pp. 389–403.

  5. Ramachandran, V. S., ‘Concrete Admixtures Handbook’. (Noyes Publications, N. Jersey) 1984 p, 116.

  6. Factor, D. F., Kinney, F., Lupyan, D. A. and M. MeFarland. A., ‘Admixtures”, Chapter 6, Cements Research Progress 1985, American Ceramic Society, Ed. P. W. Brown, pp. 147–167.

  7. Ramachandran, V. S., ‘Effect of Retarders/Water Reducers on Slump Loss in Superplasticized Concrete’, Amer. Conc. Inst. SP 68, 1987, pp. 393–407.

    Google Scholar 

  8. Ramachandran, V. S., Shihua, Z. and Beaudoin, J. J., ‘Application of Miniature Tests for Workability of Superplasticized Cement Systems’, submitted to Il Cemento.

  9. Ramachandran, V. S., ‘Adsorption and Hydration Behavior of Tricalcium Aluminate—Water and Tricalcium Aluminate—Gypsum—Water Systems in the presenè of Superplasticizers’,Amer. Conc. Inst. J. (1983) 225–241.

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ramachandran, V.S., Beaudoin, J.J. & Shihua, Z. Control of slump loss in superplasticized concrete. Materials and Structures 22, 107–111 (1989). https://doi.org/10.1007/BF02472281

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02472281

Keywords

Navigation