Skip to main content
Log in

The permeability of fly ash concrete

  • Published:
Materials and Structures Aims and scope Submit manuscript

Abstract

Oxygen permeability tests were carried out on plain ordinary Portland cement (OPC) and fly ash concretes at three nominal strength grades. Prior to testing the concretes were subjected to a wide range of curing and exposure conditions. The results emphasize the importance of adequate curing to achieve concrete of low permeability, especially when the ambient relative humidity is low. In addition, the results demonstrate the considerable benefit that can be achieved by the use of fly ash in concrete. Even under conditions of poor curing, fly ash concrete is significantly less permeable than equal-grade OPC concrete, the differences being more marked for higher-grade concretes. Attempts were made to correlate strength parameters with permeability but it is concluded that neither the strength at the end of curing nor the 28-day strength provides a reliable indicator of concrete permeability. A reliable correlation was established between the water to total cementitious material ratio [w/(c+f)] and the permeability of concretes subjected to a given curing and exposure regime.

Resume

On a effectué des essais de perméabilité sur des bétons de ciment Portland ordinaire non armé (OPC) et sur des bétons aux cendres volantes de trois classes de résistance nominale. Auparavant, on a soumis les bétons à toute une gamme de conditions de conservation et d’exposition. Les résultats font ressortir l’importance d’une conservation adéquate pour obtenir un béton de faible perméabilité, surtout quand l’humidité relative ambiante est basse, et démontre, de plus, l’avantage considérable que procure l’utilisation de cendres volantes dans le béton.

Même dans des conditions médiocres de conservation, le béton aux cendres volantes est beaucoup moins perméable que le béton OPC de classe équivalente, les différences étant plus marquées pour des bétons de haute classe. On s’est efforcé d’établir une corrélation entre les paramètres de la résistance et la perméabilité, mais on a conclu que ni la résistance en fin de conservation, ni la résistance à 28 jours, ne sont des témoins fiables de la perméabilité du béton. On a établi une corrélation sûre entre le rapport eau/matériau cimenteux total (w/(c+f)) et la perméabilité des bétons soumis à une conservation donnée et à un régime d’exposition.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Manmohan, D. and Mehta, P. K., ‘Influence of pozzolanic, slag and chemical admixtures on pore size distribution and permeability of hardened cement paste,’,Cement Concr. Aggreg. 3(1) (1981) 63–67.

    Article  Google Scholar 

  2. Marsh, B. K., Day, R. L. and Bonner, D. G., ‘Pore structure characteristics affecting the permeability of cement paste containing fly ash,’Cement Concr. Res. 15(6) (1985) 1027–1038.

    Article  Google Scholar 

  3. Thomas, M. D. A., Matthews, J. D. and Haynes, C. A., ‘The effect of curing on the strength and permeability of PFA concrete,’ in American Concrete Institute SP-114, edited by V. M. Malhotra (ACI, Detroit, 1989) pp. 191–217.

    Google Scholar 

  4. British Standards Institution, ‘Specification for Portland Cements,’ BS 12 (BSI, London, 1989).

    Google Scholar 

  5. Lawrence, C. D., ‘Measurements of permeability’, in Proceedings of 8th International Congress on the Chemistry of Cement’, Rio de Janeiro, 1986, Vol. 5, pp. 29–34.

  6. Chen Zhang Hong and Parrott, L. J., ‘Air permeability of cover concrete and the effect of curing,’ BCA report C/5 (British Cement Association, Slough, UK, 1989).

    Google Scholar 

  7. Ho, D. W. S., Cui, Q. Y. and Ritchie, D. J., ‘The influence of humidity and curing time on the quality of concrete,’Cement Concr. Res. 19(3) (1989) 457–464.

    Article  Google Scholar 

  8. Powers, T. C., ‘Structure and physical properties of hardened Portland cement paste’,J. Am. Ceram. Soc. 41(1) (1958) 1–6.

    Article  Google Scholar 

  9. Thomas, M. D. A., ‘The effect of curing on the hydration and pore structure of hardened cement paste containing pulverized fuel ash,’Adv. Cement Res. 2(8) (1989) 181–188.

    Google Scholar 

  10. Neville, A. M., ‘Properties of Concrete,’ (Pitman, London, 1981).

    Google Scholar 

  11. Ben-Bassat, M., Nixon, P. J. and Hardcastle, J., ‘The effect of differences in the composition of Portland cement on the properties of hardened concrete,’Mag. Concr. Res. 42(151) (1990) 59–66.

    Article  Google Scholar 

  12. Thomas, M. D. A., ‘An investigation of 10-year old concrete bridges constructed with conventional opc and pulverized fuel ash concretes,’Proc. Inst. Civil Engrs Part 1 86 (1989) 1111–1128.

    Google Scholar 

  13. Thomas, M. D. A., Matthews, J. D., Osborne, G. J. and Cripwell, J. B., ‘A comparison of the properties of opc, pfa and ggbs concretes in reinforced concrete walls of slender section,’Mag. Concr. Res. 42(152) (1990) 127–134.

    Google Scholar 

  14. Thomas, M. D. A., ‘A comparison of the properties of opc and pfa concrete in 30-year old mass concrete structures’, in ‘Durability of Building Materials and Components’, edited by J. M. Baker, P. J. Nixon, A. J. Majumdar and H. Davies (Spon, London, 1990) pp. 383–394.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Thomas, M.D.A., Matthews, J.D. The permeability of fly ash concrete. Materials and Structures 25, 388–396 (1992). https://doi.org/10.1007/BF02472254

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02472254

Keywords

Navigation