Abstract

A comparative study of four absorbable suture materials, namely; poly-N-acetylglucosamine (Chitin), polyglycolic acid (PGA), plain catgut and chromic catgut, in terms of strength, elongation, tensile strength retention and tissue reaction, was undertaken. The straight pull strength of USP 3–0 size Chitin was over 2.6 kg, compared with PGA, which was over 3.4 kg and the catguts, which were over 2.0 kg. Chitin showed the lowest elongation among the four. The tensile strength retention (TSR) of Chitin in muscle was 45 per cent at 14 days and 7 per cent at 25 days, which was similar to that of PGA. The TSR of Chitin was maintained by 35 per cent in gastric juice, 97 per cent in bile and 100 per cent in pancreatic juice after immersion for 30 days. The corresponding values for PGA were 54 per cent, 0 per cent and 0 per cent, respectively, whereas both catguts had dissolved within 30 days. The tissue reaction of Chitin was similar to that of PGA, whereas the catguts caused more intense tissue reaction.

This is a preview of subscription content, access via your institution.

References

  1. Nakajima M, Ihara A, Atsumi K, Kibune K, Shinozaki M. A development of new absorbable suture material from chitin. Ika Kikaigaku 1983; 53: 130–131. (in Japanese)

    Google Scholar 

  2. Yaita A, Sugimachi K, Mine H, Okudaira N, Nakamura T, Inokuchi K. An evaluation of surgical suture materials on alimentary tract anastomosis; especially a comparison of polyglycolic acid suture (PGA) and catgut. Rinsho Geka 1976; 31: 629–633. (in Japanese)

    Google Scholar 

  3. Kobayashi H, Tsuzuki M. Suture materials and their applications. Rinsho Geka 1983; 38: 735–740. (in Japanese)

    Google Scholar 

  4. Hayashi S. Advancements of suture materials. Sogo Rinsho 1984; 33: 233. (in Japanese)

    Google Scholar 

  5. Hayashi S. Problems of suture materials. Shujutsu 1981; 35: 787–801, 911–921, 1049–1061. (in Japanese)

    Google Scholar 

  6. Maetani S. Comparative studies of intestinal anastomoses. Nippon Geka Gakkai Zasshi (J Jpn Surg Soc) 1974; 75: 612–622. (in Japanese)

    Google Scholar 

  7. Natsuda Y, Kamio H, Yaita A, Sugimachi K, Nakamura T, Inokuchi K. Evaluation of absorbable suture materials in biliary tract surgery. Rinsho Geka 1978; 33: 1477–1481. (in Japanese)

    Google Scholar 

  8. Kitajima M, Sohma S. Effect of suture materials on healing wounds of the intestinal tract. Rinsho Geka 1980; 35: 1512–1521. (in Japanese)

    Google Scholar 

  9. Seki K. Problems of suture materials in alimentary anastomoses. Geka Chiryo 1973; 28: 712–716. (in Japanese)

    Google Scholar 

  10. Endo M, Nakayama K, Yazawa Y, Hanyu F, Suzuki S, Nakamura K, Yamada K. Endoscopic studies of the stomach and the suture. Rinsho Geka 1971; 26: 391–399. (in Japanese)

    Google Scholar 

  11. Chu CC. Thein vitro degeneration of poly (glycolic acid) sutures-effect of pH. J Biomed Mater Res 1981; 15: 795–804.

    PubMed  CAS  Article  Google Scholar 

  12. Salthouse TN, Matlaga BF. Polyglactin 910 suture absorption and the role of cellular enzymes. Surg Gynecol Obstet 1976; 142: 544–550.

    PubMed  CAS  Google Scholar 

Download references

Author information

Affiliations

Authors

Rights and permissions

Reprints and Permissions

About this article

Cite this article

Tachibana, M., Yaita, A., Taniura, H. et al. The use of chitin as a new absorbable suture material—An experimental study. The Japanese Journal of Surgery 18, 533–539 (1988). https://doi.org/10.1007/BF02471487

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02471487

Key Words

  • absorbable suture material
  • Chitin
  • PGA