Skip to main content
Log in

Prevention of myopotential inhibition of unipolar QRS-inhibited demand pacemakers

  • Original Articles
  • Published:
The Japanese journal of surgery Aims and scope Submit manuscript

Abstract

Seventy-two unipolar QRS-inhibited demand pacemakers were examined by provoking myopotential interference by exercise. Filter characteristics of 5 kinds of generators were tested by the use of sin2 wave pulse. Each myosignal of the major pectoral muscle and the abdominal rectus muscle was subjected to Fourier transform for analyses of amplitude and frequencies. Pacemaker inhibition was observed in 42 (58 per cent) of 72 with the highest frequency in the push up test. In this test, the incidence of myopotential inhibition was significantly lower (p<0.01) on the pacemaker implantations in the abdominal wall than that in the anterior chest wall. The myosignals of the major pectoral muscle had sufficient frequency and power density for triggering the QRS sensing mechanism but the abdominal muscular signals did not. To avoid myopotential inhibition of unipolar ventricular inhibited demand pacemakers it is most effective to implant multiprogrammable pacemakers subcutaneously in the abdominal wall and to select the optimal sensitivity according to the myopotential inhibition tests.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Parker, B., Furman, S. and Escher, D. J. W.: Input signals to pacemakers in a hospital environment. Ann. N. Y. Acad. Sci. 167: 823–834, 1969.

    PubMed  CAS  Google Scholar 

  2. Chatterjee, K., Harris, A. and Leatham, A.: The risk of pacing after infarction, and current recommendations. Lancet II: 1061–1063, 1969.

    Article  Google Scholar 

  3. Wirtzfeld, A., Lampadius, M. and Ruprecht, E-O: Unterdrückung von demandschrittmachern durch muskelpotentiale. Dtsch Med. Wschr. 97: 61–66, 1972.

    PubMed  CAS  Google Scholar 

  4. Mymin, D., Cuddy, T. E., Sinha, S. N. and Winter, D. A.: Inhibition of demand pacemakers by skeletal muscle potentials. JAMA 223: 527–529, 1973.

    Article  Google Scholar 

  5. Ohm, O.-J., Bruland, H., Pedersen, O. M. and Waerness, E.: Interference effect of myopotentials on function of unipolar demand pacemakers. Br. Heart J. 36: 77–84, 1974.

    PubMed  CAS  Google Scholar 

  6. Piller, L. W. and Kennelly, B. M.: Myopotential inhibition of demand pacemakers. Chest 66: 418–420, 1974.

    PubMed  CAS  Google Scholar 

  7. Gribbin, B., Abson, C. P. and Clarke, L. M.: Inhibition of external demand pacemakers during muscular activity. Br. Heart J. 36: 1210–1212, 1974.

    PubMed  CAS  Google Scholar 

  8. Anderson, S. T., Pitt, A., Whitford, J. A. and Davis, B. B.: Interference with function of unipolar pacemaker due to muscle potentials. J. Thorac. Cardiovasc. Surg. 71: 698–703, 1976.

    PubMed  CAS  Google Scholar 

  9. Hurvitz, R. J., Tucker, B. L., Lindesmith, G. G., Stiles, Q. R., Hughes, R. K., Wells, W. J. and Meyer, B. W.: Skeletal muscle potential (myopotential) inhibition of demand pacemakers, Cardiac Pacing, Proceedings of the 6th World Symposium on Cardiac Pacing, C. Meere, ed., Montreal, 1979, Pace Symp., Chapter 35-11.

  10. Breivik, K. and Ohm, O.-J.: Myopotential inhibition of unipolar QRS-inhibited (VVI) Pacemakers, assessed by ambulatory holter monitoring of the electrocardiogram. PACE 3: 470–478, 1980.

    PubMed  CAS  Google Scholar 

  11. Secemsky, S. I., Hauser, R. G., Denes, P. and Edwards, L. M.: Unipolar sensing abnormalities: Incidence and clinical significance of skeletal muscle interference and undersensing in 228 patients. PACE 5: 10–19, 1982.

    PubMed  CAS  Google Scholar 

  12. Echeverria, H. J., Luceri, R. M., Thurer, R. J. and Castellanos, A.: Myopotential inhibition of unipolar AV sequential (DVI) pacemaker. PACE 5: 20–22, 1982.

    PubMed  CAS  Google Scholar 

  13. Iesaka, Y., Pinakatt, T., Gosselin, A. J. and Lister, J. W.: Bradycardia dependent ventricular tachycardia facilitated by myopotential inhibition of a VVI pacemaker. PACE 5: 23–29, 1982.

    PubMed  CAS  Google Scholar 

  14. Jacobs, L. J., Kerzner, J. S., Diamond, M. A., Berlin, H. F. and Sprung, C. L.: Pacemaker inhibition by myopotentials detected by holter monitoring. PACE 5: 30–33, 1982.

    PubMed  CAS  Google Scholar 

  15. Aida, H., Yamaguchi, S., Nakajima, M., Iwanami, H. and Sakamoto, S.: Myopotential inhibition of unipolar QRS-inhibited demand pacemakers. Artificial Organs 11: 564–567, 1982 (English Abst.)

    Google Scholar 

  16. Lazar, A. V., Mihalick, M. J., Young, S. A. and Hall, R. J.: Myopotential inhibition of demand pacemakers. Texas Heart Institute Journal 9: 135–139, 1982.

    PubMed  CAS  Google Scholar 

  17. Aida, H., Yamaguchi, S., Iwanami, H. and Nakajima, M.: Myopotential inhibition of unipolar QRS-inhibited demand pacemakers. IX World Congress of Cardiology (Abst.), ed. by The Society of Cardiology of the US.S.R., Moscow, 1982, No. 416.

  18. Barold, S. S., Falkoff, M. D., Ong, L. S. and Heinle, R. A.: The third decade of cardiac pacing multiprogrammable pulse generators. Br. Heart J. 45: 357–364, 1981.

    PubMed  CAS  Google Scholar 

  19. Hauser, R. G.: Bipolar leads or cardiac pacing in the 1980s: A reappraisal provoked by skeletal muscle interference. PACE 5: 34–37, 1982.

    PubMed  CAS  Google Scholar 

  20. Widlansky, S. and Zipes, D. P.: Suppression of a ventricular-inhibited bipolar pacemaker by skeletal muscle activity. J. Electrocardiol 7: 371–374, 1974.

    Google Scholar 

  21. Barold, S. S., Ong, L. S., Falkoff, M. D. and Henle, R. A.: Inhibition of bipolar demand pacemaker by diaphragmatic myopotentials. Circulation 56: 679–683, 1977.

    PubMed  CAS  Google Scholar 

  22. Amikam, S., Peleg, H., Lemer, J. and Riss, E.: Myopotential inhibition of a bipolar pacemaker caused by electrode insulation defect. Br. Heart J. 39: 1279–1281, 1977.

    PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Aida, H. Prevention of myopotential inhibition of unipolar QRS-inhibited demand pacemakers. The Japanese Journal of Surgery 13, 470–479 (1983). https://doi.org/10.1007/BF02469489

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02469489

Key Words

Navigation