Summary
A new procedure for continuous cleanup and concentration of hydroxyvitamin D3 metabolites prior to their separation by HPLC and UV-detection is reported. The process is based on the use of aminopropyl-silica as solid-phase sorbent as an alternative to the use of nonpolar sorbents. The improvement thus achieved has been tested by comparing the results with those obtained using octadecyl-C18 as non-polar sorbent. The comparison has been based on the calibration graphs (linear range, detection and quantitation limits), precision and multiple standard addition method.
Similar content being viewed by others
Abbreviations
- 25-(OH)-D3 :
-
25-hydroxyvitamin D3
- 24,25-(OH)2-D3 :
-
24,25-dihydroxyvitamin D3
- 1,25-(OH)2-D3 :
-
1,25-didydroxyvitamin D3
References
H. F. DeLuca, J.FASEB 224 (1988).
R. Bouillon, andH. Van Baelen, J. Saudi Med.10, 260 (1989).
M. R. Walters, Endocrin. Rev.13, 719 (1992).
K. Shimada, N. Kobayashi, Trends Anal. Chem.10, 103 (1991).
M. L. Traba, M. Babe, C. de la Piedra, M. Marin, Clin. Chem.29, 1806 (1983).
V. Justova, Z. Wildtova, V. Pacovsky J. Chromatogr.290, 107 (1984).
J. Bruton, H. L. Wray, D. Dawson, V. Butler, Clin. Chem.31, 783 (1985).
F. P. Armbruster, H. Reichel, G. Vogel, G. H. Georgousis, H. Schmidt-Gayk, Clin. Chim. Acta.189, 97 (1990).
H. Koyama, J. M. Prahl, A. Uhland, M. Nanjo, M. Inaba, H. Nishiziwa, H. Morii, Y. Nishii, H. DeLuca, Anal. Biochem.205, 213 (1992).
I. Holmberg, K. Saarem, J. I. Perdersen, I. Bjorkhem, Anal. Biochem.159, 317 (1986).
E. B. Mawer, J. T. Hann, J. Chromatogr. Biomed. Appl.59, 305 (1987).
G. Jones, Clin. Chem.24, 287 (1978).
T. Iwata, M. Yamaguchi, H. Hanazono, Y. Imazato, M. Nakamura, Y. Ohkura, Anal. Sci.6, 361 (1990).
M. Shimizu, K. Kamashi, Y. Nishii, S. Yamada, Anal. Biochem.194, 77 (1991).
J. Osredkar, L. Vrhovec, J. Liq. Chromatogr.112, 1897 (1989).
T. Okano, N. Tsugawa, K. Kobayashi J. Chromatogr.493, 63 (1989).
B. Yeung, P. Vouros J. Chromatogr.645, 115 (1993).
S. Komuro, I. Nakatsuka, A. Yoshitake, Biol. Mass Spectr.23, 33 (1994).
R. D. Coldwell, D. H. L. Traford, H. L. J. Makin, J. Mass Spectrom.30, 348 (1995).
T. J. Gilbertson, R. P. Stryd, Clin. Chem.23, 1700 (1977).
P. C. Kao, D. W. Heser, Clin. Chem.30, 56 (1984).
F. Ortiz-Boyer, J. M. Fernandez-Romero, M. D. Luque de Castro, J. M. Quesada, J. Liq. Chromatogr.4, 14 (1997).
F. Ortiz-Boyer, J. M. Fernandez-Romero, M. D. Luque de Castro, J. M. Quesada J. Chromatogr. B.696, 43 (1997).
F. Ortiz-Boyer, J. M. Fernandez-Romero, M. D. Luque de Castro, J. M. Quesada, Clin. Chim. Acta (in press).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Boyer, F.O., Fernández Romero, J.M., Luque de Castro, M.D. et al. Aminopropyl-silica as an advantageous alternative to nonpolar sorbents for continuous cleanup/preconcentration of vitamin D3 metabolites. Chromatographia 47, 367–372 (1998). https://doi.org/10.1007/BF02466466
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02466466