Abstract
Doppler spectrograms obtained by using autoregressive (AR) modelling based on the Yule-Walker equations were investigated. A complex AR model using the in-phase and the quadrature components of the Doppler signal was used to provide blood-flow directions. The effect of model orders on the spectrogram estimation was studied using cardiac Doppler blood flow signals taken from 20 patients. The ‘final prediction error’ (FPE) and the ‘Akaike's information criterion’ (AIC) provided almost identical results in model-order selection. An index, the spectral envelope area (SEA), was used to evaluate the effect of window duration and sampling frequency on AR Doppler spectrogram estimation. The statistical analysis revealed that the SEA obtained from AR modelling was not sensitive to window duration and sampling frequency. This result verified the consistency of the AR Doppler spectrogram. The white-noise characteristics of the AR modelling error signal indicated that the Doppler blood-flow signal can be adequately modelled as a complex AR process. With appropriate model orders, AR modelling provided better Doppler spectrogram estimates than the periodogram.
Similar content being viewed by others
References
Box, G. E. P. andJenkins, G. M. (1976)Time series analysis: forecasting and control. (revised edn.), Holden-Day, San Francisco.
Cannon, S. R., Richards, K. L. andRollwitz, W. T. (1982) Digital Fourier techniques in the diagnosis and quantification of aortic stenosis with pulse Doppler echocardiography.J. Clin. Ultrasound,10, 101–107.
Cloutier, G., Lemire, F., Durand, L. -G., Latour, Y. andLanglois, Y. E. (1990) Computer evaluation of Doppler spectral envelope area in patients having a valvular aortic stenosis.Ultrasound in Med. & Biol.,16, 247–260.
Cloutier, G., Allard, L., Guo, Z. andDurand, L. -G. (1992) The effect of averaging cardiac Doppler spectrograms on the reduction of their amplitude variability.Med. & Biol. Eng. & Comput.,30, 177–186.
Giddens, D. P. andKitney, R. I. (1985) Blood flow disturbances and spectral analysis. InNoninvasive diagnostic techniques in vascular disease.Bernstein, E. F. (Ed.), The C.V. Mosby Co., St Louis, 58–68.
Guo, Z., Durand, L. -G., Allard, L., Cloutier, G. Lee, H. C. andLanglois, Y. E. (1993) Cardiac Doppler blood-flow signal analysis. Part 1 Evaluation of the normality and stationarity of the temporal signal.Med. & Biol. Eng. & Comput.,31.
Herment, A. Demoment, G., Dumee, Ph. andArcile, C. (1990) High-resolution and low variance, real-time spectral analysis of Doppler signals. 12th Ann. Conf. IEEE EMBS, Philadelphia, Pennsylvania, 1st–4th Nov., 310–311.
Kaluzynski, K. (1987) Analysis of application possibilities of autoregressive modelling to Doppler blood flow signal spectral analysis.Med. & Biol. Eng. & Comput.,25, 373–376.
Kaluzynski, K. (1989a) Order selection in Doppler blood flow signal spectral analysis using autoregressive modelling. —Ibid.,27, 89–92.
Kaluzynski, K. (1989b) Selection of a spectral analysis method for the assessment of velocity distribution based on the spectral distribution of ultrasonic Doppler signals. —Ibid.,27, 463–469.
Kay, S. M. andMarple, S. L. (1981) Spectrum analysis—a modern perspective.Proc. IEEE,69, 1380–1419.
Kitney, R. I., Talhami, H. andGiddens, D. P. (1986) The analysis of blood velocity measurements by autoregressive modelling.J. Theor. Biol.,120, 419–442.
Mo, L. Y. andCobbold, S. C. (1986) “Speckle” in continuous wave Doppler ultrasound spectra: a simulation study.IEEE Trans.,UFFC-33, 747–753.
Panidis, I. P., Mintz, G. S. andRoss, J. (1986) Value and limitations of Doppler ultrasound in the evaluation of aortic stenosis: a statistical analysis of 70 consecutive patients.Am. Heart J.,112, 150–158.
Rittgers, S. E. (1987) Signal processing of Doppler information.Echocardiography,4, 7–15.
Schlindwein, F. S. andEvans, D. H. (1989) A real-time autoregressive spectrum analyzer for Doppler ultrasound signal.Ultrasound in Med. & Biol.,15, 263–272.
Schlindwein, F. S. andEvans, D. H. (1989) Selection of the order of autoregressive model for spectral analysis of Doppler ultrasound signals. —Ibid.,16, 81–91.
Vaitkus, P. J. andCobbold, R. S. C. (1988) A comparative study and assessment of Doppler ultrasound spectral estimation techniques, part I: Estimation methods —Ibid.,14, 661–672.
Vaitkus, P. J., Cobbold, R. S. C. andJohnston, K. W. (1988) A comparative study and assessment of Doppler ultrasound spectral estimation techniques. Part II: Methods and results. —Ibid.,14, 673–688.
Yamaguchi, T., Kikkawa, S. andParker, K. H. (1987) Simulation of nonstationary spectral analysis of turbulence in the aorta using a modified autoregressive or maximum entropy (AR/ME) method.Med. & Biol. Eng. & Comput.,25, 533–542.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Guo, Z., Durand, L.G., Allard, L. et al. Cardiac Doppler blood-flow signal analysis. Med. Biol. Eng. Comput. 31, 242–248 (1993). https://doi.org/10.1007/BF02458043
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02458043