Impedance plethysmography for blood flow measurements in human limbs

Part 2 Influence of limb cross-sectional area

  • Modelling
  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

The cross-sectional area of a limb varies along the extremity. This is of great importance when impedance plethysmography is used for limb blood flow studies. The actual measurement site, as well as the interelectrode distance, must be carefully selected to avoid underestimation of the blood flow value. The distance between the potential electrodes should be less than 10 cm for an adult subject.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Dahn, I. (1964) On the calibration and accuracy of segmental calf plethysmography with a description of a new expansion chamber and a new sleeve.Scand. J. Clin. & Lab. Invest.,16, 347–356.

    Google Scholar 

  • Dahn, I., Jonson, B. andNilsen, R. (1970). A plethysmographic method for determination of flow and volume pulsations in a limb.J. Appl. Physiol.,28, 333–336.

    Google Scholar 

  • Fleming, J. S., Hames, T. K. andSmallwood, J. (1986) Comparison of volume changes in the forearm assessed by impedance and water-displacement plethysmography.Med. & Biol. Eng. & Comput.,24, 375–378.

    Article  Google Scholar 

  • Greenfield, A. D. M. (1960) Venous occlusion plethysmography. InMethods in medical research, Year Book Publ., Chicago, Illinois, USA, 293–301.

    Google Scholar 

  • Hill, D. W. andHope, C. E. (1976) Computer techniques in blood flow measurement. InClinical blood flow measurement.Woodcock, J. (Ed.) Sector Publishing, London, 169–176.

    Google Scholar 

  • Kubicek, W. G., Witsoe, D. A., Patterson, R. P. andFrom, A. H. L. (1971) Development and evaluation of an impedance cardiographic system to measure cardiac output and other cardiac parameters. Nat. Aeronaut. Space Admin. Manned Spacecraft Center, Houston, Texas, Final Prog. Rep., Contact NAS 9-4500, 15–19.

  • Mohapatora, S. N. andArenson, H. M. (1979) The measurement of peripheral blood flow by the electrical impedance technique.J. Med. Eng. & Tech.,3, 132–137.

    Article  Google Scholar 

  • Nyboer, J. (1970)Electrical impedance plethysmography. C. C. Thomas Publ. Springfield, Illinois, USA.

    Google Scholar 

  • Öberg, P. Å., Pettersson, H. andTörngren, P. (1984) The measurement of volume changes in human limbs using airborne ultrasound. Abstract PMC 6:1, 6th IFMBE Nordic Meeting, Aberdeen.

    Google Scholar 

  • Porter, J. M. andSwain, I. D. (1986) Non-invasive measurement of limb and digit blood flow.J. Biomed. Eng.,8, 137–142.

    Google Scholar 

  • Schraibman, I. G., Mott, D., Naylor, G. P. andCharlesworth, D. (1975) Comparison of impedance and strain gauge plethysmography in the measurement of blood flow in the lower limb.Br. J. Surg.,62, 909–912.

    Google Scholar 

  • Shimazu, H., Yamakoshi, K., Togawa, T., Fukuoka, M. andIto, H. (1982) Evaluation of the parallel conductor theory for measuring human limb blood flow by electrical admittance plethysmography.IEEE Trans.,BME-29, 1–7.

    Google Scholar 

  • Whitney, R. J. (1953) The measurement of volume changes in human limbs.J. Physiol. (Lond.),121, 1–27.

    Google Scholar 

  • Yamakoshi, K., Shimazu, H., Togawa, T. andIto, H. (1978) Admittance plethysmography for accurate measurement of human limb blood flow.Am. J. Physiol.,236, H821–829.

    Google Scholar 

  • Yamamoto, Y., Yamamoto, T. andÖberg, P. Å. (1991) Impedance plethysmography in human limbs. Part 1. On electrodes and electrode geometry.Med. & Biol. Eng. & Comput.,29, 419–424.

    Article  Google Scholar 

  • Young, D. E. Jr., Cox, R. H., Stoner, E. K. andErdman, W. J. (1967a) Evaluation of quantitative impedance plethysmography for continuous blood flow measurement, I. Electrode systems.Am. J. Phys. Med.,46, 1261–1275.

    Google Scholar 

  • Young, D. G. Jr., Cox, R. H., Stoner, E. K. andErdman, W. J. (1967b) Evaluation of quantitative impedance plethysmography for continuous blood flow measurement, III. Blood flow determination in vivo. —Ibid.,,46, 1450–1457.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Yamamoto, Y., Yamamoto, T. & Öberg, P.Å. Impedance plethysmography for blood flow measurements in human limbs. Med. Biol. Eng. Comput. 30, 518–524 (1992). https://doi.org/10.1007/BF02457831

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02457831

Keywords

Navigation