Summary
The expressions for the corrections to the frequency of the3 P 2−3 P 1 and3 P 1−3 P 0 π-transitions of Mg and Ca are derived, taking into account the anomalous magnetic moment of the electron as well as the diamagnetic term of the Hamiltonian. Numerical results for24Mg are given.
Riassunto
Si riportano le espressioni analitiche per la correzione di frequenza dovuta all'effetto Zeeman del second'ordine per le transizioni π del tripletto3 P di Mg e Ca. Le correzioni tengono conto del momento magnetico anomalo dell'elettrone e del termine dell'Hamiltoniana responsabile del comportamento diamagnetico dell'atomo. Sono forniti i risultati numerici per il24Mg.
Резюме
Выводятся выражения для поправок к частоте3 P 2−3 P 1 и3 P 1−3 P 0 π-переходов для Mg и Ca, учитывая аномальный магнитный момент электрона, а также диамагнитный член Гамильтониана. Приводятся численные результаты для24Mg.
Similar content being viewed by others
References
F. Strumia:Metrologia,8, 85 (1972).
A. Godone, E. Bava andC. Novero:Metrologia,24, 133 (1987).
E. Bava, A. Godone, G.Giusfredi andC.Novero:IEEE J. Quantum Electron. QE-23, No. 4 (Apr. 1987).
L. Landau, E. Lifchitz:Mécanique Quantique (Editions Mir, Moscou, 1974).
E. U. Condon, G. M. Shortley:The Theory of Atomic Spectra (Cambridge University Press, Cambridge, 1970).
P. O. Löwdin:Phys. Rev.,97, 1474 (1955).
I. Shavitt:Modern Theoretical Chemistry, Vol. 3, edited byH. F. Schaefer III (New York, N. Y., 1977), p. 189.
S. F. Boys:Proc. R. Soc. London, Ser. A,200, 542 (1950).
M. M. Francl, W. J. Pietro, W. J. Hehre, J. S. Binkley, M. S. Gordon, D. J. DeFrees andJ. A. People:J. Chem. Phys.,77, 3654 (1982);B. Roos, A. Veillard andG. Vinot:Theor. Chim. Acta,20, 1 (1970). The atomic basis sets have been optimized in their valence part.
E. R. Davidson:J. Comp. Phys.,17, 87 (1975);K. I. Iberle andE. R. Davidson:J. Chem. Phys.,76, 5385 (1982).
E. R. Cohen, B. N. Taylor:J. Reas. NBS,92, 85 (1987).
M. Inguscio, K. R. Leopold, J. S. Murray andK. M. Evenson:J. Opt. Soc. Am. B,2, 1566 (1985).
N. Beverini andF. Strumia:High precision measurements of the Zeeman effect in the calcium metastable states, Volume in honour of Prof.A. Gozzini (Pisa, 1987);F. Strumia:Application of laser cooling to the atomic frequency standards, to be published inLaser Science and Technology, edited byA. N. Chester andS. Martellucci (Plenum Press, New York, N. Y., 1987).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Novero, C., Godone, A., Bava, E. et al. Quadratic Zeeman corrections for metastable levels of Mg and Ca. Il Nuovo Cimento D 10, 841–846 (1988). https://doi.org/10.1007/BF02450143
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF02450143