Skip to main content
Log in

Application of a novel PRODUCTIVTM CM column in egg-white protein separation: Effect of high flow-rate on resolution and productivity

  • Published:
Biotechnology Techniques

Summary

A preparative PRODUCTIVTM CM, a new coherent ion-exchanger, column (250×10 mm ID) has been used to separate egg-white proteins without cell debris remover (CDR) pretreatment. Results showed that the productivity increased with the superficial velocity (Vs) and a very high Vs (9.2 m/h) can benefit the high productivity (87.4 g/l.h) in comparison with 6.4 and 33 g/l.h as reported by others. Despite the high flow-rate and high column loading, the resolution of the eluted peaks of lysozyme and conalbumin, was maintained at 1.16.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Levison P. R., Toome D. W., Badger S. E., Brook B. N. and Carcary D. (1989).Chromatography, 28, 3/4, 170–178.

    Article  CAS  Google Scholar 

  • Levison P. R., Badger S. E., Toome D. W., Carcary, D. and Butts E. T. (1990). inAdvances in Separation Processes. 6.1-6.11, The Inst. of Chem. Engs, Hemisphere Publishing Co. U.K.

    Google Scholar 

  • Lane L., Kosciely, M. L., Levison P. R. (1990).Bioseparation. 1, 141–147.

    CAS  Google Scholar 

  • Roe S. (1989). inSeparation Based on Structure in Protein Purification Methods A Practical Approach. Eds Harris E. L. V. and Angal S. 175–245, IRL Press, Oxford Univ. Press, U. K.

    Google Scholar 

  • Skidmore, G. L. and Chase, H. A. (1988). inIon Exchange for Industry, 520–532, Ellis Horwood Ltd.

  • Fang Ming and Howell J. A. (1992).Bioseparation, 2, 289–295.

    Google Scholar 

  • Fang Ming and Howell J. A. (1991).J. Chromat., 539, 2, 255–265.

    Article  Google Scholar 

  • Henry P. M., (1989). inHPLC of Macromolecules A Practical Approach Ed. Oliver R. W. A., 91–125, IRL Oxford Univ Pr, U.K.

    Google Scholar 

  • Hames, B. D. (1986). inGel Electrophoresis of Proteins: Preactical Approach. Eds Hames, B. D. and Rickwood, D., 40, IRL Oxford Univ. Pre, U.K..

    Google Scholar 

  • Rhodes M. B., Azari P. R., Feency R. E. (1958).J. Biol. Chem. 230, 399–408.

    CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ming, F., Howell, J.A. Application of a novel PRODUCTIVTM CM column in egg-white protein separation: Effect of high flow-rate on resolution and productivity. Biotechnol Tech 6, 433–438 (1992). https://doi.org/10.1007/BF02447484

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02447484

Keywords

Navigation