Eight-channel ultrasonic displacement meter for implantable miniature sensors

  • T. Nakamura
  • K. Hayashi
  • J. Seki
Technical Note

Keywords

Eight-channel operation Implantable miniature sensor Transit time Ultrasonic displacement meter 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Bertram, C. D. (1977) Ultrasonic transit-time system for arterial diameter measurement.Med. & Biol. Eng. & Comput.,15, 489–499.Google Scholar
  2. Goodman, C. A. andCastellana, F. S. (1982) A digital sonomicrometer for two-point length and velocity measurements.Am. J. Physiol.,243, H634-H639.Google Scholar
  3. Nakamura, T., Hayashi, K., Taenaka, Y., Umezu, M., Nakatani, T. andTakano, H. (1986a) Ultrasonic flowmeter for implantable miniature sensors.Med. & Biol. Eng. & Comput.,24, 235–242.CrossRefGoogle Scholar
  4. Nakamura, T., Hayashi, K., Seki, J., Nakatani, T., Noda, H., Fukuda, S., Takano, H. andAkutsu, T. (1986b) Eight-channel ultrasonic displacement meter for the measurement of myocardial dimensions during cardiac assist. Proc. IEEE 1985 Ultrasonics Symposium (San Francisco), 860–863.Google Scholar
  5. Nakamura, T., Hayashi, K., Seki, J., Nakatani, T., Noda, H., Fukuda, S., Takano, H. andAkutsu, T. (1986c) Bulk and regional mechanical work of ischemic heart during left ventricular assistance. Progress in Artif. Organs-1985 (Proc. Vth World Cong. Internat. Soc. Artif. Organs, Chicago), 447–451.Google Scholar
  6. Patrick, T. A., Vatner, S. F., Kemper, W. S. andFranklin, D. (1974) Telemetry of left ventricular diameter and pressure measurements from unrestrained animals.J. Appl. Physiol.,37, 276–281.Google Scholar
  7. Rushmer, R. F., Franklin, D. L. andEllis, R. M. (1956) Left ventricular dimensions recorded by sonocardiometry.Circ. Res.,4, 684–688.Google Scholar
  8. Sia, J. B., Pace, D. G., Osborne, M. W., Zanko, M. T. andKovzelove, F. (1980) An improved signal processor for the ultrasonic dimension gauge.Cardiovasc. Res.,14, 490–494.Google Scholar
  9. Stegall, H. F., Kardon, M. B., Stone, H. L. andBiship, V. S. (1967) A portable, simple sonomicrometer.J. Appl. Physiol.,23, 289–293.Google Scholar
  10. Stinson, E. B., Rahmoeller, G. andTecklenberg, P. L. (1974) Measurement of internal left ventricular diameter by a tracking sonomicrometer.Cardiovasc. Res.,8, 283–289.CrossRefGoogle Scholar
  11. Tomoike, H., Ootsubo, H., Sakai, K., Kikuchi, Y. andNakamura, M. (1981) Continuous measurement of coronary artery diameterin situ.Am. J. Physiol.,240, H73-H79.Google Scholar

Copyright information

© IFMBE 1987

Authors and Affiliations

  • T. Nakamura
    • 1
  • K. Hayashi
    • 1
  • J. Seki
    • 1
  1. 1.Department of Biomedical EngineeringNational Cardiovascular Center Research InstituteOsakaJapan

Personalised recommendations