Abstract
An optimal control system for the intra-aortic balloon pump (IABP) is presented. Control of the IABP is based on a performance index formulated to reflect a tradeoff between maximising cardiac oxygen supply and minimising cardiac oxygen consumption. In the performance index, mean diastolic pressure (MDP) was used to represent oxygen availability and peak systolic pressure (PSP) was used to represent oxygen consumption. An algorithm, implemented using an 8-bit microcomputer, changes the deflation time of the IABP to maximise this performance index by using an optimisation technique that employs both a search and an approximation. The search produces three equally spaced points which define a region that includes the maximum of the performance index. From these points, the optimum deflation time is estimated by a quadratic approximation. The algorithm has been successfully tested using performance index curves generated by computer simulations.
Similar content being viewed by others
References
Adby, P. R. andDempster, M. A. H. (1974) Single variable optimization. InIntroduction to optimization methods.Adby, P. R. andDempster, M. A. H. (Eds.), Chapman & Hall, London.
Barnea, O. (1987) Cardiovascular dynamics and the intraaortic balloon pump: optimization based on cardiac oxygen balance. Ph.D. Thesis, Drexel University, Philadelphia, Pennsylvania, USA.
Barnea, O., Smith, B., Moore, T. W. andJaron, D. (1989) AN optimal control algorithm for intra-aortic balloon pumping. 11th Int. Conf. IEEE EMBS, Seattle, Washington, USA.
Box, M. J., Davies, D. andSwann, W. H. (1969)Non-linear optimization techniques. Oliver & Boyd, Edinburgh.
Clark, J. W., Kane, G. R. andBourland, H. M. (1973) On the feasibility of closed-loop control of intra-aortic balloon pumping.IEEE Trans.,BME-20, 404–412.
Jablkowski andSerafin, J. (1980) Parameter optimization of intra-aortic balloon pumping.Trans. ISAO/IFAC Symp.,2, 245–266.
Jaron, D., Moore, T. W. andHe, P. (1983) Theoretical considerations regarding the optimization of cardiac assistance by intraaortic balloon pumping.IEEE Trans.,BME-30, 177–186.
Jaron, D., Moore, T. W. andHe, P. (1985) Control of intraaortic balloon pumping: theory and guidelines for clinical applications.Ann. Biomed. Eng.,13, 155–175.
Kane, G. R., Clark, J. W., Bourland, H. M. andHartley, C. J. (1971) Automatic control of intra-aortic balloon pumping.Trans. Am. Soc. Artif. Intern. Organs,17, 148–152.
Thakor, N. V., Webster, J. G. andTompkins, W. J. (1983) Optimal QRS detector.Med. & Biol. Eng. & Comput.,21, 343–350.
Williams, M. J., Rubin, J. W. andEllison, R. G. (1977) Experimental determination of optimum performance of counterpulsation assist pumping under computer control.Comput. Biomed. Res.,10, 545–559.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Smith, B., Barnea, O., Moore, T.W. et al. Optimal control system for the intra-aortic balloon pump. Med. Biol. Eng. Comput. 29, 180–184 (1991). https://doi.org/10.1007/BF02447105
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF02447105