New algorithm for the detection of the ECG fiducial point in the averaging technique

  • Physiological Measurement
  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

The use of the coherent averaging technique applied to the electrocardiographic signal implies the location of a fiducial point as a synchronisation reference. An algorithm easily adaptable to a personal computer, operable in real time, insensitive to mains and to ECG-baseline fluctuations, with a low jitter value and the capacity to trigger any ECG signal wave or complex, has been developed. The algorithm detects those waveforms which, within certain confidence intervals, are morphologically equal to a reference wave. This wave is chosen by the user as the repetitive waveform within which the fiducial point is to be located. A two-window template and differential parameters are used. The possibility of building the template permits the user to adapt the algorithm to each patient's ECG. To evaluate its accuracy objectively, a software simulation was built of a generator capable of producing test signals as the sum of the ‘useful’ signal plus ‘noise’. A jitter standard deviation of 1·65 ms was obtained in the worst test (SNR=10 dB; noiseband=0–50 Hz), which shows the excellent recognition accuracy of the algorithm.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Abboud, S. andSadeh, D. (1982) The waveforms' alignment procedure in the averaging process for external recording of the His bundle activity.Comput. Biomed. Res.,15, 212–219.

    Article  Google Scholar 

  • Ahlstrom, M. L. andTompkins, W. (1983) Automated high-speed analysis of holter tapes with microcomputers.IEEE Trans.,BME-30, 651–657.

    Google Scholar 

  • Amazeen, P. G., Moruzzi, R. L. andFeldman, C. L. (1972) Phase detection of R waves in noisy electrocardiograms. ——Ibid. -19, 63–66.

    Google Scholar 

  • Barbaro, V., Bartolini, P., Bolle, G., Ialongo, D. andMarietti, P. (1983) Experience for recording electrical activity from his bundle by non invasive method.Innov. Tech. Biol. Med.,4, 103–112.

    Google Scholar 

  • Barbaro, V., Bartolini, P., Becchetti, G., di Mascolo, R., Ialongo, D. andStanzani, S. (1985) Acquisition and elaboration system for recording of high amplification ECG signals. Proc. 14th Int. Conf. on Med. & Biol. Eng./7th Int. Conf. on Med. Phys., Espoo, Finland, 11th–16th Aug. 1985.Med. & Biol. Eng. & Comput.,23, Suppl., Part 2, 1460–1461.

    Google Scholar 

  • Barbaro, V., Bartolini, P., Becchetti, G., di Mascolo, R. andIalongo, D. (1986) High amplification electrocardiography: detection of late ventricular potentials. Proc. IV Mediterr. Conf. on Med. & Biol. Eng., 9th–12th Sept. 1986, Sevilla, Spain, 734–737.

  • Brandon, C. W. andBrody, D. A. (1970) A hardware trigger for temporal indexing of the electrocardiographic signal.Comput. Biomed. Res.,3, 47–57.

    Article  Google Scholar 

  • Cahill, S. J. andMcClure, G. (1983) A microcomputer-based heart-rate variability monitor.IEEE Trans.,BME-30, 87–93.

    Google Scholar 

  • Craelius, W., Restivo, M., Assadi, M. A. andEl-Sherif, N. (1986) Criteria for optimal averaging of cardiac signals.IEEE Trans.,BME-33, 957–966.

    Google Scholar 

  • Denniss, A. R., Richards, D. A., Farrow, R. H., Davison, A., Ross, D. L. andUther, J. B. (1986) Technique for maximizing the frequency response of the signal averaged Frank vector-cardiogram.J. Biomed. Eng.,8, 207–212.

    Google Scholar 

  • de Vel, O. Y. (1984) R-wave detection in the presence of muscle artifacts.IEEE Trans.,BME-31, 715–717.

    Google Scholar 

  • Fraden, J. andNeuman, M. R. (1980) QRS wave detection.Med. & Biol. Eng. & Comput.,18, 125–132.

    Article  Google Scholar 

  • Goovaerts, H. G., Ros, H. H., Akker, T. J. andSchneider, H. (1976) A digital QRS detector based on the principle of contour limiting.IEEE Trans.,BME-23, 154–160.

    Google Scholar 

  • Hanna, K. L. (1980) Firmware for a patient monitoring station.Hewlett-Packard J.,31, (11), 23–28.

    MathSciNet  Google Scholar 

  • Jesus, S. andRix, H. (1988) High resolution ECG analysis by an improved signal averaging method and comparison with a beat-to-beat approach.J. Biomed. Eng.,10, 25–32.

    Google Scholar 

  • Lindecrantz, K. G. andLilja, H. (1988) New software QRS detector algorithm suitable for real time applications with low signal-to-noise ratios. ——Ibid.,10, 280–284.

    Google Scholar 

  • Mohammad-Djafari, A., Heron, F., Deperdu, R. andPerrin, J. (1981) Noninvasive recording of the His-Purkinje system electrical activity by a digital system design. ——Ibid.,3, 147–152.

    Google Scholar 

  • Murthy, I. S. N. andRangaraj, M. R. (1979) New concepts for PVC detection.IEEE Trans.,BME-26, 409–416.

    Google Scholar 

  • Nygårds, M. E. andSörnmo, L. (1983) Delineation of the QRS complex using the envelope of the e.c.g..Med. & Biol. Eng. & Comput.,21, 538–547.

    Article  Google Scholar 

  • Okada, M. (1979) A digital filter for the QRS complex detection.IEEE Trans.,BME-26, 700–703.

    Google Scholar 

  • Pan, J. andTompkins, W. (1985) A real-time QRS detection algorithm. ——Ibid. -32, 230–236.

    Google Scholar 

  • Pande, V. N., Verma, H. K. andMukhopadhyay, P. (1985) Bedside ECG monitor using a microprocessor.Med. & Biol. Eng. & Comput.,23, 487–492.

    Google Scholar 

  • Rompelman, O. andRos, H. H. (1986) Coherent averaging technique: a tutorial review.J. Biomed. Eng.,8, 24–35.

    Google Scholar 

  • Uijen, G. J. H., de Weerd, J. P. C. andVendrik, A. J. H. (1979) Accuracy of QRS detection in relation to the analysis of high-frequency components in the electrocardiogram.Med. & Biol. Eng. & Comput.,17, 492–502.

    Google Scholar 

  • Wajszczuk, W. J., Stopczyk, M. J., Moskowitz, M. S., Zochowski, R. J., Bauld, T., Dabos, P. L. andRubenfire, M. (1978) Noninvasive recording of His-Purkinje activity in man by QRS-triggered signal averaging.Circ.,58, 95–102.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Barbaro, V., Bartolini, P. & Fierli, M. New algorithm for the detection of the ECG fiducial point in the averaging technique. Med. Biol. Eng. Comput. 29, 129–135 (1991). https://doi.org/10.1007/BF02447097

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02447097

Keywords

Navigation