Abstract
A system, to collect, analyse and display biological data, is developed using IBM PC AT compatibles (PCs) or CED1401/1609 devices networked to a VAX environment. It can be operated in three separate modes: using the CED/IEEE/VAX network; using the PC/Ethernet/VAX network; as a standalone PC. The original system comprised CED 1401/1609 data collection devices running on the IEEE bus. This has been superseded by a PC-286 or better incorporating an analogue-to-digital convertor (DT2824-PGH) and a communications interface board (DEPCA) linked by thinwire Ethernet (ThinWire) running DECnet with their product network application software PCSA. This network has not only doubled the original throughput but has also removed the two major IEEE constraints: 4 m between devices and the physical linking of devices to the VAX. The PCs are logically linked to clustered VAXes on Ethernet, giving flexible networking supporting multiple ThinWire segments, each supporting a maximum of 30 PCs per 185 m segment length. As the enhanced design compliments the original, both may operate concurrently, appear similar in operation to the user and use the same analysis software, all of which help reduce the rate of system obsolescence.
Similar content being viewed by others
References
Anderson, S. M. andPepperberg, D. R. (1988) Versatile software for collection, analysis and plotting of biochemical data using the IBM PC.Comp. Meth. and Prog. in Biomed.,26, 267–274.
Diaspro, A. andNicolini, C. A. (1988) Computer acquisition and analysis of thermal profiles from differential scanning calorimeter.Comput. Meth. and Prop. in Biomed.,27, 75–78.
Dunnington, D. J., Pinsky, S., Mattes, D., Prichett, W., Earl, C. Q., Greig, R. andAnzano, M. A. (1988) Automation of data acquisition and processing in assays for anchorage-independent growth: application to the purification of epithelial transforming growth factor.Analyt. Biochem.,174, 257–264.
Frackelton, W. H. andMiddaugh, D. L. (1988) Automated acquisition and analysis of animal behavior data utilizing an Apple IIe.Physiol. Behav.,43, (2), 253–257.
Keenan, P. K. andKrawetz, S. A. (1988) Computer video acquisition and analysis system for biological data.CABIOS,4, (1), 203–210.
McGuffie, G. P. andMorley, D. A. (1988) A microcomputer program for analog data collection with peak analysis.Med. Lab. Sci.,45, 182–183.
Marlow, S. andMackenzie, D. A. R. (1989) Distributed computer system for capture, analysis and display of biological data.Med. & Biol. Eng. & Comput.,27, 371–378.
Morita, K. andIkeda, K. (1988) Evaluation of a microcomputer-based clinical laboratory data acquisition system linked with a minicomputer-based patient data management system.J. Clin. Monit.,4, 48–58.
Schanus, E. G., Caviness, G. O., Kahl, J. L. andHerrick, I. W. (1988) Micro-computer based system for data acquisition and analysis of oxygen uptake studies.LIPIDS,23, (4), 362–366.
Schwid, H. A. (1988) Electrocardiogram simulation using a personal computer.Comp. & Biomed. Res.,21, 562–569.
Silvern, D. A., Tsunekage, T., Gupte, P. M. andArai, T. (1988) A real-time data acquisition & analysis system using commercially available hardware & software.J. of Clin. Eng.,13, 427–432.
Stanley, T. E., Held, P. J. andEstrin, J. A. (1989) Automated data acquisition and analysis in muscle physiology research.Comp. Meth. and Prog. in Biomed.,28, 273–279.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Marlow, S.P., Mackezie, D.A.R. & Tomlinson, J.B. PC/VAX or standalone PC-based general purpose biological data collection system. Med. Biol. Eng. Comput. 31, 22–30 (1993). https://doi.org/10.1007/BF02446881
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02446881