Wet-wedge spirometer for the accurate continuous measurement of ventilation under anaesthesia

  • S. A. O'Connor
  • D. J. Wilkinson
  • G. R. Dickson
  • B. J. Ashley
Article

Abstract

A wet-wedge spirometer which continuously and accurately measures tidal volume in the spontaneously breathing anaesthetised patient has been developed. This spirometer may be adapted for use with any anaesthetic system which employs a reservoir bag and expiratory-relief valve. The performance of this apparatus both in the laboratory and in the operating theatre has shown the device to be linear, sensitive and suitable for routine anaesthetic use. Measurement of tidal volume was accurate within ±3·5 per cent of reading up to respiratory frequencies of 60 breaths per minute independent of the fresh gas flow. The resistance of the anaesthetic circuit remained within normally accepted limits when used with this spirometer.

Keywords

Anaesthesia Bag-in bottle principle Respiratory depression Ventilation Wet-wedge spirometer 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Adams, A. P., Vickers, M. D. A., Munroe, J. P. andParker, C. W. (1967) Dry displacement gas meters.Br. J. Anaesth.,39, 174–183.Google Scholar
  2. Ashutosh, K., Gilbert, R., Auchincloss, J. H., Erlebacher, J. andPeppi, D. (1974) Impedance pneumograph and magnetometer methods for monitoring tidal volume.J. Appl. Physiol.,37, 964–966.Google Scholar
  3. Beatty, P. (1983) Zero-drift correction device for a respiratory pneumotachograph.Med. & Biol. Eng. & Comput.,21, 109–112.Google Scholar
  4. Bushman, J. A. (1979) Effect of different flow patterns on the Wright respirometer.Br. J. Anaesth.,51, 895–898.Google Scholar
  5. Byles, P. H. (1960) Observations on some continuously-acting spirometers.,32, 470–475.Google Scholar
  6. Cohn, M. A., Rao, A. S. V., Broudy, M., Birch, S., Watson, H., Atkins, N., Davis, B., Scott, F. D. andSackner, M. A. (1982) The respiratory inductive plethysmograph: a new non-invasive monitor of respiration.Bull. Eur. Physiopathol. Respir.,18, 643–658.Google Scholar
  7. Conway, C. M., Leigh, J. M., Preston, T. D., Walters, F. J. M. andWebb, D. A. (1974) An assessment of three electronic spirometers.Br. J. Anaesth.,46, 885–891.Google Scholar
  8. Cooper, E. A. (1959) The estimation of minute volume.Anaesthesia,14, 373–378.Google Scholar
  9. Cooper, E. A. (1969) The measurement of ventilation.Br. J. Anaesth.,41, 718–722.Google Scholar
  10. Deno, N. S., Barlett, H. L. andBuskirk, E. R. (1978) Respiratory flow integrator with improved stability.J. Appl. Physiol.,44, 619–622.Google Scholar
  11. Ditchburn, R. K., Hull, D. andSegall, M. M. (1966) Oxygen uptake during and after positive-pressure ventilation for the resuscitation of axphysiated newborn infants.Lancet,2, 1096–1099.CrossRefGoogle Scholar
  12. Donald, K. W. andChristie, R. V. (1949) A new method of clinical spirometry.Clin. Sci.,8, 21–31.Google Scholar
  13. Epstein, R. A. andEpstein, M. A. F. (1980) Automatic rezeroing of drifting physiologic signals.Med. & Biol. Eng. & Comput. 18, 746–748.CrossRefGoogle Scholar
  14. Fry, D. L., Hyatt, R. E., McCall, C. B. andMallos, A. J. (1957) Evaluation of three types of respiratory flowmeters.J. Appl. Physiol.,10, 210–214.Google Scholar
  15. Grenvik, A., Hedstrand, U. andSjögren, H. (1966) Problems in pneumotachography.Acta Anaesthesiol. Scand.,10, 147–155.CrossRefGoogle Scholar
  16. Konno, K. andMead, J. (1967) Measurement of the separate volume changes of rib cage and abdomen during breathing.J. Appl. Physiol.,22, 407–422.Google Scholar
  17. Lundsgaard, J. S., Grønlund, J. andEiner-Jensen, N. (1979) Evaluation of a constant-temperature hot-wire anemometer for respiratory-gas-flow measurements.Med. & Biol. Eng. & Comput.,17, 211–215.CrossRefGoogle Scholar
  18. Mead, J., Peterson, N., Grimby, G. andMead, J. (1967) Pulmonary ventilation measured from body surface movements.Science,156, 1383–1384.Google Scholar
  19. Nott, M. R. andNorman, J. (1978) Resistance of Heidbrink-type expiratory valves.Br. J. Anaesth.,50, 477–480.Google Scholar
  20. Nunn, J. F. (1956) A new method of spirometry applicable to routine anaesthesia.,28, 440–449.Google Scholar
  21. Nunn, J. F. (1958) Respiratory measurements in the presence of nitrous oxide.,30, 254–263.Google Scholar
  22. Nunn, J. F. andEzi-Ashi, T. I. (1962) The accuracy of the respirometer and ventigrator.,34, 422–432.Google Scholar
  23. Nunn, J. F. (1969)Applied respiratory physiology, 1st edn. Butterworths, London, 83 and 171.Google Scholar
  24. Scott, J. C. andFlanagan, G. J. (1973) Improvement of an infant peneumotachograph.Anaesthesia,28, 59–65.Google Scholar
  25. Stephen, G. W., Davie, I. andScott, D. B. (1970) A method of spirometry during general anaesthesia.Br. J. Anaesth.,42, 109–112.Google Scholar
  26. Wright, B. M. (1955) A respiratory anemometer.J. Physiol.,127, 25P.Google Scholar

Copyright information

© IFMBE 1985

Authors and Affiliations

  • S. A. O'Connor
    • 1
  • D. J. Wilkinson
    • 1
  • G. R. Dickson
    • 1
  • B. J. Ashley
    • 1
  1. 1.Departments of Medical Electronics and AnaesthesiaSt. Bartholomew's HospitalLondonEngland

Personalised recommendations