Small-opening microwave applicator for noninvasive diagnosis and monitoring

  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

A new type of microwave applicator is proposed for vessel kinetic measurements and monitoring purposes. It is obtained from a standard coaxial-waveguide adaptor connected to a tapered matching junction which is progressively loaded by a dielectric slab with electromagnetic properties approximately equal to those of the surface tissues of human body. Design criteria are given and experimental results are reported.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  • Bedini, L., Bramanti, M. andDenoth, F. (1979) Progetto e realizzazione di una sonda induttiva per la rilevazione transcutanea del movimento di grossi vasi.Alta Frequenza,XLVIII, 88–98.

    Google Scholar 

  • Bramanti, M. andCalamia, M. (1969) A tapered waveguide-to-waveguide adapter.IEEE Trans. Microwave Theory & Tech.,MTT-17, 116–118.

    Article  Google Scholar 

  • Guy, A. W., Lehmann, J. F., Stonebridge, J. B. andSorensen, C. C. (1978) Development of a 915-MHz direct contact applicator for therapeutic heating of tissues.IEEE Trans. Microwave Theory & Tech.,MTT-26, 550.

    Article  Google Scholar 

  • Johnson, C. C. andGuy, A. W. (1972) Nonionizing electromagnetic wave effects in biological materials and system.Proc. IEEE,60, 692–718.

    Article  Google Scholar 

  • Kantor, G., Witters, D. M. andGreiser, J. W. (1978) The performance of a new direct contact applicator for microwave diathermy'.IEEE Trans. Microwave Theory & Tech.,MTT-26, 563–568.

    Article  Google Scholar 

  • Pedersen, P. C., Johnson, C. C., Durney, C. N. andBragg, D. G. (1976) An investigation on the use of microwave radiation for pulmonary diagnosis.IEEE Trans. Biomed. Eng.,23, 410–412.

    Google Scholar 

  • Pedersen, P. C., Johnson, C. C., Durney, C. N. andBragg, D. G. (1978) Microwave reflection and transmission measurements for pulmonary diagnosis and monitoring.IEEE Trans. Biomed. Eng. 25, 40–48.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Bramanti, M. Small-opening microwave applicator for noninvasive diagnosis and monitoring. Med. Biol. Eng. Comput. 19, 215–217 (1981). https://doi.org/10.1007/BF02442717

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02442717

Keywords

Navigation