Abstract

The essential concepts, design and operation of a microprocessor controlled multichannel dynamic radiograph are described. This dynamic radiograph, which detects radiation scattered from within the chest cavity, is used to accurately monitor two- and three-dimensional epicardial motion patterns. The basic concepts of the new radiograph are validated with a set of experiments on mechanical models. The results of the initial testing on experimental animals are presented.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Dack, S. andPaley, D. H. (1952) Electrokymography.Am. J. Medicine,12, 331.

    Article  Google Scholar 

  • Gibson, D. G., Brown, D. J. andLogan-Sinclair, R. B. (1978) Analysis of left ventricular wall movement by phased array echocardiography.Br. Heart J.,40, 1334–1338.

    Google Scholar 

  • Heimer, M. L., Jacobs, A. M., Kenney, E. S., Shiroff, R. andWeidner, W. A. (1977) Implementing an automatic control system for dynamic radiography.Med. & Biol. Eng. & Comput.,15, 168–178.

    Google Scholar 

  • Jacobs, A. M. andKenney, E. S. (1972) Dynamic radiography. A new imaging technique using penetrating radiation.Proc. Soc. Photo-Opt. Instrum. Eng.,29, 17–22.

    Google Scholar 

  • Nellis, S. H., Liedtke, A. J., Heimer, W. L., Shiroff, R. A., Jacobs, A. M., Kenney, E. S., Weidner, W. A., McInerney, J. J. andZelis, R. (1980) Validation of dynamic radiography in the dog and evaluations of ischemic dyssynergy.Am. J. Physiol.,238, H43-H53.

    Google Scholar 

  • Parisi, A. F., Moynihan, P. F., Folland, E. D., Strauss, W. E., Sharma, G. V. R. K. andSasahara, A. A. (1980) Echocardiography in acute and remote myocardial infarction.Am. J. Cardiol.,46, 1205–1214.

    Article  Google Scholar 

  • Tilley, D. G., Jacobs, A. M., Kenney, E. S., Weidner, W. A. andMiller, K. L. (1976) Dynamic radiography, a technique employing scattered radiation to monitor surface motion.J. Med. & Biol. Eng.,14, 141.

    Google Scholar 

  • Weiss, J. L., Eaton, L. W., Manghan, W. L., Brinker, J. A., Bulkley, B., Guzman, P. andYin, F. C. P. (1981) Ventricular size and shape by two-dimensional echocardiography.Federation Proc.,40, 2031–2036.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

McInerney, J.J., Nellis, S.H., Zelis, R. et al. Microprocessor controlled multichannel dynamic radiograph. Med. Biol. Eng. Comput. 20, 661–670 (1982). https://doi.org/10.1007/BF02442518

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02442518

Keywords

Navigation