Abstract
A programmable calculator has been successfully employed for implementation of computational algorithms for pulmonary mechanics to increase productivity by reducing calculation time.
The phase-angle and the zero-crossing methods of calculation have been compared and, although they have inherently distinctive algorithms and different calculation speeds, neither method possesses a distinct advantage over the other. The compliance and airway resistance values obtained in our laboratory by the two methods using the programmable calculator are fairly consistent with each other (correlation coefficient >0·93).
Sommaire
Une calculatrice programmable a été appliquée avec succès aux algorithmes de calcul des mécanismes pulmonaires pour augmenter la productivité en réduisant le temps de calcul. Après comparaison des méthodes de calcul utilisant l'angle de phase et le ‘zéro crossing’, on s'est rendu compte, bien que ces 2 méthodes utilisent des algorithmes distincts et des vitesses de calcul différentes, que ni l'une ni l'autre ne possédait d'avantages sur l'autre. L'indice de conformité et la valeur de la résistance des voies aériennes obtenues dans notre laboratoire par les deux méthodes avec une calculatrice programmable se tiennent coefficient de corrélation 0·93).
Zusammenfassung
Ein programmierfähiger, Rechner ist mit Erfolg zur Anwendung von Berechnungsalgorithmen für den Lungenmechnismus benutzt worden, um durch Herabsetzung der Berechnungszeit die Produktivität zu erhöhen. Die Phasenwinkel- und Nullkreuzungsmethoden der Berechnung sind verglichen worden, und obwohl sie grundsätzlich verschiedene Algorithmen und unterschiedliche Berechnungsgeschwindigkeiten haben, besitzt keine Methode einen deutlichen Vorteil gegenzber der anderen. Die in unserem Labor mit den beiden Methoden unter Verwendung des programmierfähigen Rechners erzielten Nachgiebigkeits- und Luftwegwiderstandswerte sind einander einigermaßen gleich (Korrelatinnskoeffizient:...0·93).
Similar content being viewed by others
References
Bergland, G. D. (1969) A guided tour of the Fourier transform.IEEE Spectrum,6, 41–52.
Dubois, A. B., Brody, A. W., Lewis, D. H. andBurgess, Jr., B. F. (1956) Oscillation mechanics of the lungs and chest in man.J. Appl. Physiol.,8, 587–594.
Hewlett-Packard (1973)9830 calculator operating and programming manual. Hewlett-Packard Calculator Products Division.
Hilberman, M., Stacy, R. W. andPeters, R. M. (1972) A phase method of calculating respiratory mechanics using a digital computer.J. Appl. Physiol. 32, 535–541.
Mead J. (1961) Mechanical properties of lungs.Physiol. Rev. 41, 281–330.
Michaelson, E. D., Grassman, E. D. andPeters, W. R. (1975) Pulmonary mechanics by spectral analysis of forced random noise.J. Clin. Investigation. 56, 1210–1230.
Olson, H. F. (1958)Dynamic analysis. 2nd edn. Van Nostrand Reinhold. New York, 278.
Otis, A. B., McKerrow, C. B., Bartlett, R. A., Mead, J., McIlroy, M. B., Selverstone, N. J. andRadford, Jr., E. P. (1956) Mechanical factors in distribution of pulmonary ventilation.J. Appl. Physiol. 8, 427–433.
Peters, R. M. (1969)The mechanical basis of respiration. Little, Brown. Boston, Mass. 88–102.
Roth, P. R. (1971) Effective measurements using digital signal analysis.IEEE Spectrum,8, 62–70.
Shephard, R. J. (1966) Dynamic characteristics of the human airway and the behaviour of unstable breathing systems.Aerosp. Med.,37, 1014–1021.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Yoo, J.H.K., Hander, E.W. & Petroff, P.A. Implementation of computation algorithms for pulmonary mechanics on a programmable calculator. Med. Biol. Eng. Comput. 15, 528–533 (1977). https://doi.org/10.1007/BF02442280
Issue Date: