Abstract
The tensile testing of biological materials poses specific problems. Biological tissue may slip in the grips of the tensometer during tensile testing, and this needs to be taken into account in the calculation of strain. The inherent variability of tissue samples requires that a large number of samples be analysed to adequately characterise a given biological structure. These problems have been addressed by integrating a digital video dimensional analyser and a microcomputer into a system that can be attached to most tensometers. Features of the system are: automated data acquisition, analysis and filing; resolution of load and extension to better than 0·1 per cent of full scale; and achievable high throughput.
Similar content being viewed by others
Abbreviations
- strain i :
-
strain at some timei
- l o :
-
length at the start of the test
- l i :
-
length at some timei
- t o :
-
scan time between two detection markers at the start of the test
- t i :
-
scan time between two detection markers at some timei
References
Berg, W. S., Stahurski, T. M., Moran, J. M. andGreenwald, A. S. (1983) Mechanical properties of bovine xenografts. 29th Ann. ORS, Anaheim, California, 87.
Betsch, D. F. andBaer, E. (1980) Structure and mechanical properties of rat tail tendon.Biorheol.,17, 83–94.
Butler, D. L., Grood, E. S., Noyes, F. R., Zernicke, R. F. andBrackett, K. (1984) Effects of structure and strain measurement technique on the material properties of young human tendons and fascia.J. Biomech.,17, 579–596.
Elliott, D. H. (1965) Structure and function of mammalian tendon.Biol. Rev.,40, 392–421.
Haut, R. C. (1983) Age dependent influence of strain rate on the tensile failure of rat-tail tendon. 29th Ann. ORS., Anaheim, California, 85.
Intaglietta, M. andTompkins, W. R. (1972) On-line measurement of microvascular dimensions by television microscopy.J. Appl. Physiol. (USA),32, 546–551.
Lanir, Y. andFung, Y. C. (1973) Two-dimensional mechanical properties of rabbit skin. 1 Experimental system.J. Biomech.,7, 29–34.
Masen, M., Eulenberger, J., Schneider, E., Rahn, B., Segmuller, G. andPerren, S. M. (1986) A biomechanical, histological, and surface ultrastructural evaluation of tendons in response to internal fixation plates. 32nd Ann. ORS, New Orleans, Louisiana, 214.
Milthorpe, B. K., Rogers, G. J., Schindhelm, K. andFarrell, P. C. (1986) Measurement of the mechanical properties of tendons using a microcomputer video dimensional analyser. InProgress in Artificial Organs—1985.Nose, Y., Kjellerstrand, C. andIvanovich, P. (Eds.), ISAO Press, 1111–1115.
Webster, D. A. andWerner, F. W. (1983) Mechanical and functional properties of implanted freeze-dried flexor tendons.Clin. Orthop. Rel. Res.,180, 238–243.
Woo, S. L.-Y., Akeson, W. H. andJellott, G. F. (1976) Measurements of nonhomogeneous, directional mechanical properties of articular cartilage in tension.J. Biomech.,9, 785–791.
Woo, S. L.-Y., Ritter, M., Amiel, D., Sanders, T. M., Gomez, M. A., Kuel, S. C., Garfin, S. R. andAkeson, W. H. (1980) The biomechanical and biochemical properties of swine tendons—long term effects of exercise on the digital extensors.Connect. Tiss. Res.,7, 177–183.
Woo, S. L.-Y. (1982) Mechanical properties of tendons and ligaments: 1. Quasi-static and nonlinear viscoelastic properties.Biorheol.,19, 385–396.
Yamada, H. (1970)Strength of biological materials. Williams & Wilkins, Baltimore.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Milthorpe, B.K., Rogers, G.J. & Schindhelm, K. Microcomputer-based system for tensile testing of biological materials. Med. Biol. Eng. Comput. 26, 161–166 (1988). https://doi.org/10.1007/BF02442259
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF02442259