Abstract

The tensile testing of biological materials poses specific problems. Biological tissue may slip in the grips of the tensometer during tensile testing, and this needs to be taken into account in the calculation of strain. The inherent variability of tissue samples requires that a large number of samples be analysed to adequately characterise a given biological structure. These problems have been addressed by integrating a digital video dimensional analyser and a microcomputer into a system that can be attached to most tensometers. Features of the system are: automated data acquisition, analysis and filing; resolution of load and extension to better than 0·1 per cent of full scale; and achievable high throughput.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Abbreviations

strain i :

strain at some timei

l o :

length at the start of the test

l i :

length at some timei

t o :

scan time between two detection markers at the start of the test

t i :

scan time between two detection markers at some timei

References

  • Berg, W. S., Stahurski, T. M., Moran, J. M. andGreenwald, A. S. (1983) Mechanical properties of bovine xenografts. 29th Ann. ORS, Anaheim, California, 87.

  • Betsch, D. F. andBaer, E. (1980) Structure and mechanical properties of rat tail tendon.Biorheol.,17, 83–94.

    Google Scholar 

  • Butler, D. L., Grood, E. S., Noyes, F. R., Zernicke, R. F. andBrackett, K. (1984) Effects of structure and strain measurement technique on the material properties of young human tendons and fascia.J. Biomech.,17, 579–596.

    Article  Google Scholar 

  • Elliott, D. H. (1965) Structure and function of mammalian tendon.Biol. Rev.,40, 392–421.

    Article  Google Scholar 

  • Haut, R. C. (1983) Age dependent influence of strain rate on the tensile failure of rat-tail tendon. 29th Ann. ORS., Anaheim, California, 85.

  • Intaglietta, M. andTompkins, W. R. (1972) On-line measurement of microvascular dimensions by television microscopy.J. Appl. Physiol. (USA),32, 546–551.

    Google Scholar 

  • Lanir, Y. andFung, Y. C. (1973) Two-dimensional mechanical properties of rabbit skin. 1 Experimental system.J. Biomech.,7, 29–34.

    Article  Google Scholar 

  • Masen, M., Eulenberger, J., Schneider, E., Rahn, B., Segmuller, G. andPerren, S. M. (1986) A biomechanical, histological, and surface ultrastructural evaluation of tendons in response to internal fixation plates. 32nd Ann. ORS, New Orleans, Louisiana, 214.

  • Milthorpe, B. K., Rogers, G. J., Schindhelm, K. andFarrell, P. C. (1986) Measurement of the mechanical properties of tendons using a microcomputer video dimensional analyser. InProgress in Artificial Organs—1985.Nose, Y., Kjellerstrand, C. andIvanovich, P. (Eds.), ISAO Press, 1111–1115.

  • Webster, D. A. andWerner, F. W. (1983) Mechanical and functional properties of implanted freeze-dried flexor tendons.Clin. Orthop. Rel. Res.,180, 238–243.

    Google Scholar 

  • Woo, S. L.-Y., Akeson, W. H. andJellott, G. F. (1976) Measurements of nonhomogeneous, directional mechanical properties of articular cartilage in tension.J. Biomech.,9, 785–791.

    Article  Google Scholar 

  • Woo, S. L.-Y., Ritter, M., Amiel, D., Sanders, T. M., Gomez, M. A., Kuel, S. C., Garfin, S. R. andAkeson, W. H. (1980) The biomechanical and biochemical properties of swine tendons—long term effects of exercise on the digital extensors.Connect. Tiss. Res.,7, 177–183.

    Article  Google Scholar 

  • Woo, S. L.-Y. (1982) Mechanical properties of tendons and ligaments: 1. Quasi-static and nonlinear viscoelastic properties.Biorheol.,19, 385–396.

    Google Scholar 

  • Yamada, H. (1970)Strength of biological materials. Williams & Wilkins, Baltimore.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Milthorpe, B.K., Rogers, G.J. & Schindhelm, K. Microcomputer-based system for tensile testing of biological materials. Med. Biol. Eng. Comput. 26, 161–166 (1988). https://doi.org/10.1007/BF02442259

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02442259

Keywords

Navigation