Data compression applied to dynamic electrocardiography

  • Physiological Measurement
  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

We have tested some techniques of ECG compression on the BIH/MIT Arrhythmias database. We have applied the following methods: (1) method of differences; (2) compression by prediction; (3) sample skipping methods; with the following kinds of errors: amplitude error, amplitude and delay error, area error. In the first and second method the average code length found after application of the Huffmann encoding has been found to be about 4 bits sample−1. For the third method the final compression ratio varies according to the allowed error; with a limited error threshold, however, we have reached an average compression a little lower than 1∶5

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Abenstein, J. P. andTompkins, W. J. (1982) A new data reduction algorithm for real-time ECG analysis.IEEE Trans.,BME-29, 43–48.

    Google Scholar 

  • Cox, J. R., Nolle, F. M., Fozzard, H. A. andOliver, G. C. (1968) AZTEC, a preprocessing program for real-time ECG rhythm analysis.—Ibid.,BME-15, 128–129.

    Google Scholar 

  • Devlin, P. andSchluter, P. (1981) Specification for FM analog database types based on the MIT-BIH digital ECG database. Beth Israel Hospital.

  • Fancott, T., Wong, D., Guimond, C. andLemire, J. (1981) Design considerations for noise immunity in the Concordia high speed ambulatory ECG Tapes analysis system. Proc. IEEE Computers in Cardiology, 343–346.

  • Harvard/MIT (1982). MIT-BIH Arrhythmia Database: tape directory and format specification. Harvard University and Massachusetts Institute of Technology Division of Health Science & Technology.

  • Ishijima, M., Shin, S., Hostetter, G. H. andSlansky, J. (1983). Scan Along Polygonal Approximation of data compression of electrocardiograms.IEEE Trans.,BME-30, 723–729.

    Google Scholar 

  • Ripley, K. L. andMurray, A. (1980)Introduction to automated arrhythmia detection. IEEE Computer Society, 71–72.

  • Ruttimann, U. E. andPipberger, H. V. (1979) Compression of the ECG by prediction or interpolation and entropy encoding.IEEE Trans.,BME-26, 613–623.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Bertinelli, M., Castelli, A., Combi, C. et al. Data compression applied to dynamic electrocardiography. Med. Biol. Eng. Comput. 27, 33–40 (1989). https://doi.org/10.1007/BF02442167

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02442167

Keywords

Navigation