Skip to main content
Log in

Evaluation of telephone transmission for computer electrocardiographic interpretation in Japan

  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

The reliability of the Japanese public telephone facilities to transmit electrocardiograms (e.c.g.) for computer interpretation was assessed. The International Business Machine's (IBM) e.c.g. computer program by Bonner was used. No appreciable distortion of e.c.g. was observed following repeated transmission from hospitals separated by 1000 km. Thirty-four normal and 66 abnormal e.c.g.s. were transmitted twice. Identical results were observed in 97% of normals and 92% of abnormals.

Following these fundamental experiments, 1236 patients' e.c.g.s. were transmitted for computer intepretation. The study showed that 98·6% (1219 cases) were technically satisfactory and 1·4% (17 cases) were not. The 17 unsatisfactory cases were classified into ten unreceivable data formats, six inconsistent measurements and one unacceptable noise level.

The authors concluded that the Japanese public telephone facilities were acceptable for the transmission of e.c.g.s. for computer interpretation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Hagan, A. D., Alpert, J. S., Nave, M. A., Rasmussen, W. T. andSilva, J. (1975). Clinical evaluation of five programs for computerised e.c.g. interpretation.Circulation 51:52, Suppl. II, 193.

    Google Scholar 

  • Hill, D. W., Mable, S. E. R. andPayne, J. P. (1976) Medical applications of analogue and digital telephone data links.Med. Prog. Technol.,4, 79.

    Google Scholar 

  • Maier, K. (1976) C.C.I.T.T.-Recommendation International standard (C.C.I.T.T.) for transmitting biomedical analogue and digital data on the public telephone network.Med. Prog. Technol.,4, 71.

    Google Scholar 

  • Watts, M. P. andMacfarlane, P. W. (1977) 3-lead electrocardiogram transmission over post office telephone lines.Med. & Biol. Eng. & Comput.,15, 311.

    Google Scholar 

  • Bonner, R. E., Crevasse, L., Ferrer, M. I. andGreenfield, J. C. (1972) A new computer program for analysis of scalar electrocardiograms.Comput. Biomed. Res.,5, 629.

    Article  Google Scholar 

  • Nakagaki, O., Tajimi, T., Shibahara, T., Nose, Y., Kuroiwa, A. andNakamura, M. (1977) Evaluation of electrocardiographic interpretation by computer program of IBM-Bonner (1974) in Japan (abstract in Japanese).Jap. Circ. J.,41, 822.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Nose, Y., Nakamura, M., Inoue, T. et al. Evaluation of telephone transmission for computer electrocardiographic interpretation in Japan. Med. Biol. Eng. Comput. 18, 727–730 (1980). https://doi.org/10.1007/BF02441897

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02441897

Keywords

Navigation