Construction of thermistor probes suitable for the estimation of cardiac output by the thermodilution method in small animals

  • R. L. B. Neame
  • D. A. Powis
  • F. J. Imms
Article

Abstract

A method for construction of thermistor probes suitable for use in small animals is described, together with some suggestions for associated circuitry. The two types of probe described are intended for use in cardiac output estimations by the thermodilution method, and although these are dimensionally suited to the rat, there is no reason why they should not be lengthened (or shortened) to suit other applications. One probe is used for estimating the difference between the temperature of the animal and the cooler, injected indicator and is passed down the right internal jugular vein to lie with its tip near to the right atrium. The other probe is for recording the temperature changes in the aortic arch produced by the passage of cold indicator and is passed through the left common carotid artery to lie with its tip in the aortic arch.

Keywords

Estimation of cardiac output Thermistor-probe construction Thermodilution method 

Sommaire

La méthode de fabrication de sondes à thermistance convenant à une utilisation sur de petits animaux est décrite et quelques suggestions sont données en ce qui concerne les circuits associés. Les deux types de sondes décrits sont destinés à être utilisés pour les évaluations du travail cardiaque par la méthode de la thermodilution et bien que les sondes soient adaptées aux dimensions du rat, il n'y a aucune raison pour qu'elles ne soient pas allongées (ou raccourcies) pour convenir à d'autres applications. Une sonde est utilisée pour l'évaluation de la différence entre la température de l'animal et celle, plus froide, de l'indicateur injecté. Cette dernière est introduite dans la veine jugulaire interne droite de façon que son extrémité soit placée pres de l'orifice de l'oreillette droite. L'autre sond est utilisée pour l'enregistrement des variations de température dans la crosse de l'aorte provoquées par le passage de l'indicateur froid et elle est introduite dans la carotide commune gauche de manière que son extrémité soit placée dans la crosse de l'aorte.

Zusammenfassung

Es wird das Bauverfahren für Thermistorsonden beschrieben, die sich zur Verwendung bei kleinen Tieren eignen, in Verbindung mit einigen Vorschlägen für die zugehörige Verdrahtung. Die zwei beschriebenen Sondentypen sind zur Verwendung in Herzleistungsschätzungen durch die Thermo-Verdünnungsmethode bestimmt, und obwohl ihre Dimensionen der Ratte entsprechen, besteht kein Grund, warum sie nicht verlängert (oder verkürzt) werden können, um anderen Anwendungen zu entsprechen. Eine Sonde wird zur Schätzung des Unterschiedes zwischen der Temperatur des Tieres und des kühleren eingeführten Anzeigers verwendet, und wird durch die rechte interne Kehlader geführt, um mit ihrer Spitze neben der rechten Vorkammer zu liegen. Die andere Sonde dient zur Aufzeichnung der Temperaturänderungen im Hauptschalgaderbogen, die durch den Durchgang kalten Anzeigers verursacht werden, und wird durch die linke Halsschlagader geführt, um mit ihrer Spitze im Hauptschlagaderbogen zu liegen.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Fegler, G. (1954) Measurement of cardiac output in anaesthetized animals by a thermo-dilution method.Q. Jl. Exp. Physiol. 39, 153–164Google Scholar
  2. Fegler, G. (1957) The reliability of the thermodilution method for determination of cardiac output and the blood flow in central veins.-42, 254–266Google Scholar
  3. Hamilton, W. F. (1962) Measurement of the cardiac output. In:Handbook of physiology, vol. 1, section 2: 551–584. American Physiological Society, Washington DCGoogle Scholar
  4. Hanwell, A. andLinzell, J. L. (1972) Validation of the thermodilution technique for the estimation of cardiac output in the rat.Comp. Biochem. Physiol. 41A, 647–657.CrossRefGoogle Scholar
  5. Houdas, Y., Ketelers, J-Y., Houdas-Heyraud, C. andLerche, E. (1969) La thermodilution appliquée à la mesure du débit cardiaque des petits animaux de laboratoire, principalement le rat.Path. Biol., Paris 17, 1069–1078Google Scholar
  6. Lin, Y. C., Dawson, C. A., Nadel, E. R. andHorvath, S. M. (1970) Reliability of cardiac output measured by thermodilution method in small animals.Comp. Biochem. Physiol. 34, 245–250CrossRefGoogle Scholar
  7. Neame, R. L. B. (1973) A study of the rat adrenal: the control of its glucocorticoid secretion and its cardiovascular significance. Ph.D. thesis, University of LondonGoogle Scholar
  8. Williams, J. C. P., O'Donovan, T. P. B. andWood, E. H. (1966) A method for the calculation of areas under indicator-dilution curves.J. Appl. Physiol. 21, 695–699Google Scholar

Copyright information

© International Federation for Medical & Biological Engineering 1977

Authors and Affiliations

  • R. L. B. Neame
    • 1
    • 2
  • D. A. Powis
    • 1
    • 2
  • F. J. Imms
    • 1
    • 2
  1. 1.Department of PhysiologyThe Medical College of St. Bartholomew's HospitalLondonEngland
  2. 2.MRC Environmental Physiology UnitLondon School of Hygiene and Tropical MedicineLondonKeppell StreetEngland

Personalised recommendations