Variability of thoracic impedance cardiograms in man

  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

The variability of thoracic impedance cardiogram signals was studied in a normal population with the objective of determining the effect of different respiratory manoeuvres and the optimal criteria for acquisition of this type of physiological signal. The variability of the first derivative of the thoracic impedance signal (dZ/dt) was determined at each 5ms intervals along the signal as the ensemble confidence limits of 3% and 97% around the coherent average. The results obtained indicate that: (a) signal variability is minimum during respiratory apnea (p<0.05) as compared with apneusis or normal respiration, (b) signal patterns are different during apnea and apneusis, and (c) during normal respiration the cardiac component of the thoracic impedance signal can be extracted from the respiratory noise by coherent average yielding a signal with the same pattern obtained during apnea.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Baker, L. E., Judy, W. V., Geddes, L. E., Langley, F. M. andHill, D. W. (1971) The measurement of cardiac output by means of electrical impedance.Cardiovasc. Res. Cent. Bull. Houston,9, 135–145.

    Google Scholar 

  • Boer, P., Ross, J. C., Geyskes, G. G. andDorhout Mees, E. J. (1979) Measurement of cardiac output by impedance cardiography under various conditions.Am. J. Physiol.,237, H491-H496.

    Google Scholar 

  • Endresen, J. andHill, D. W. (1976) The effect of respiration on the monitoring of stroke volume and cardiac output by the electrical impedance technique.Eur. J. Intensive Care Med.,2, 3–6.

    Article  Google Scholar 

  • Hill, D. W. andMohapatra, S. N. (1977) The current status of electrical impedance techniques for the monitoring of cardiac output and limb blood flow. InHill, D. W. andWatson, B. W. (Ed.)IEEE Medical Electronics Monographs 23–27. Peter Peregrinus Ltd., Stevenage.

    Google Scholar 

  • Hughes, A. andGrawoig, D. (1971)Statistics: a foundation for analysis. Addison-Wesley, London.

    Google Scholar 

  • Kubicek, W. G., Karnegis, J. N., Patterson, R. P., Witsoe, D. A. andMattson, R. H. (1966) Development and evaluation of an impedance cardiac output system.Aerospace Med.,37, 1208–1212.

    Google Scholar 

  • Kubicek, W. G., Kottke, F. J., Ramos, M. U., Patterson, R. P., Witsoe, D. A., Lambree, J. W., Remole, W., Layman, T. E., Schoening, H. andGaramela, J. T. (1974) The minnesota impedance cardiograph—theory and applications.Biomed. Eng.,9, 410–417.

    Google Scholar 

  • Lababidi, Z., Ehmke, D. A., Durin, R. E., Leverton, P. E. andLaver R. M. (1970) The first derivative thoracic impedance cardiogram.Circulation,41, 651–658.

    Google Scholar 

  • Nyboer, L., Bagno, S., Barnett, A. andHalsey, R. H. (1940) Radiocardiograms: electrical impedance changes of the heart in relation to electrocardiograms and heart sounds.J. Clin. Invest.,19, 963.

    Google Scholar 

  • Nyboer, J., Bagno, S., Barnett, A. andHalsey, R. H. (1970) Impedance cardiograms and differentited-impedance cardiograms—the electrical impedance changes of the heart in relation to electrocardiograms and heart sounds.Ann. N.Y. Acad. Sci.,170, 421–435.

    Google Scholar 

  • Patterson, R. P., Kubicek, W. G., Witsoe, D. A. andFrom, A. H. L. (1978) Studies on the effect of controlled volume change on the thoracic electrical impedance.Med. & Biol. Eng. & Comput.,16, 531–536.

    Google Scholar 

  • Ramos, M. U. (1977) An abnormal early diastolic impedance waveform: a predictor of poor prognosis in the cardiac patient?Am. Heart J.,94, 274–281.

    Google Scholar 

  • Robotham, J. L., Lixfeld, W., Holland, L., McGregor, D., Gryan, A. C. andRobson, J. (1978) Effects of respiration on cardiac performance.J. Appl. Physiol.: Resp. Environ. Exerc. Physiol.,44, 703–709.

    Google Scholar 

  • Robotham, J. L. andMetzner, W. (1979) A model of the effects of respiration on left ventricular performance.J. Appl. Physiol.: Resp. Environ. Exerc. Physiol.,46, 411–418.

    Google Scholar 

  • Wadhwani, R. andLongini, R. E. (1973) Analysis of quiet spontaneous breathing as measured by spirometer and electrical impedance plethysmography.Comput. & Biomed. Res.,6, 74–89.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

de Souza, W.M., Panerai, R.B. Variability of thoracic impedance cardiograms in man. Med. Biol. Eng. Comput. 19, 411–415 (1981). https://doi.org/10.1007/BF02441304

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02441304

Keywords

Navigation