Abstract
Laser-Doppler anemometry is relatively new technique which is used for measuring velocity fields. It has major applications in the field ofin vitro biofluid mechanics. The laser-Doppler anemometers have many advantages compared with the traditional hot-wire or hot-film anemometers which are still mainly used in studies of biofluid mechanics. A laser-Doppler anemometer (I.d.a) system which can be used to measurein vitro velocity and shear-stress profiles in the vicinity of prosthetic heart valves is described. Accurate velocity measurements in the vicinity of prosthetic heart valves are very scarce, and the use of I.d.a systems will facilitate acquisition of these data.
Similar content being viewed by others
References
Affeld, K., Zartnack, F., Mohnhaupt, R. andBücherl, E. S. (1976) New methods for thein vitro investigations of the flow patterns in artificial hearts.Trans. Am. Soc. Artif. Int. Organs 22, 460–467.
Durst, F., Melling, A. andWhitelaw, J. H. (1976)Principles and practice of laser-Doppler anemometry, Academic Press, New York.
Figliola, R. A. (1976) A study of the hemolytic potential of prosthetic heart valve flows based on localin vitro stress measurements. M.S. thesis, University of Notre Dame, Indiana.
Swope, R. D. andFalsetti, H. L. (1976) Velocity profiles in prosthetic heart valves under steady flow conditions. 29th ACEMB, 339.
Wang, C. P. (1977) Laser anemometry.Am. Sci. 65, 289–293.
Weiting, D. W. (1969) Dynamic flow characteristics of heart valves Ph.D. thesis, University of Texas, Austin.
Yoganathan, A. P., Corcoran, W. H. andHarrison, E. C. (1976)In vitro velocity measurements in the vicinity of aortic prostheses. 69th annual AIChE meeting, Chicago, Illinois.
Yoganathan, A. P. (1978) Cardiovascular fluid mechanics. Ph.D. thesis, California Institute of Technology, Pasadena.
Yoganathan, A. P., Corcoran, W. H. andHarrison, E. C. (1978a)in vitro velocity measurements in the vicinity of aortic prostheses.J. Biomech. (to be published).
Yoganathan, A. P., Corcoran, W. H., Harrison, E. C. andCarl, J. R. (1978b) The Björk-Shiley aortic prosthesis: Flow characteristics, thrombus formation and tissue overgowth.Circulation,58, 70–76.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Yoganathan, A.P., Reamer, H.H., Harrison, E.C. et al. Laser-doppler anemometer to study velocity fields in the vicinity of prosthetic heart valves. Med. Biol. Eng. Comput. 17, 38–44 (1979). https://doi.org/10.1007/BF02440952
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02440952