Abstract
During a few past years a series of shock-wave generators for lithotripsy and/or tissue destruction studies have been developed in our laboratory. Based on the experiences in shock wave measurements and the drawbacks in existing hydrophones, we have developed a very low-cost, wideband, reproducible shock-wave hydrophone. The key element of this device is the rapidly mounting, disposable PVDF membrane. This is a commercially available PVDF shock gauge which is poled by a patented cyclic poling technique. To obtain the widest possible bandwidth, we have adopted a special coplanar membrane design. The PVDF film is sandwiched between the surfaces of a P.V.C. and a metallic plate of brass which the latter is in contact with the surrounding medium. On the other hand, the active lead is isolated from medium and it is in contact with an isolating liquid (degassed petroleum) held in a cylindrical chamber over the membrane. By the incorporation of this design, the hydrophone can be used for shock wave measurements even in conductive media like different physiological liquids, with a negligible change of sensitivity.
Similar content being viewed by others
References
Chaussy C., Brendel W., Schmiedt E. (1980) Extracorporeally induced destruction of kidney stones by shock waves; Lancet ii:1265–1268
Coleman A.J., Saunders J.E. (1992) A review of the physical properties and biological effects of the high amplitude acoustic fields used in extracorporeal lithotripsy; Ultrasonics, vol. 31 2:75–85
Flynn H.G. (1964) Physics of acoustic cavitation in liquids, In: Mason W.P. ed., Physical acoustics: principals and methods; vol. 1B, New York, Academic press; 57–112
Coleman A.J., Saunders J.E., Crum L.A., Dyson M. (1987) Acoustic cavitation generated by an extracorporeal shock wave lithotripter; Ultrasound Med. Biol., 13:69–76
Church C.C. (1989) A theoretical study of cavitation generated by an extracorporeal shock wave lithotripter; J. Acoust. Soc. Am., vol. 86, 1:215–227
Cathignol D., Chapelon J.Y. (1993) High energy ultrasound therapy, In: Hobaek H. ed., Advances in nonlinear acoustics; 13th International Symposium on Nonlinear Acoustics, Bergen, 30–35
Chen Y.L., Israelachvili J. (1991) New mechanism of cavitation damage; Science, 252:1157–1160
Prat F., Cathignol D. (1994) Focused liver ablation by cavitation in the rabbit: A potential new method of extracorporeal treatment; Gut, 35:395–400
Lewin P.A., Schafer M.E. (1991) Shock wave sensors: I. Requirements and design; J. Lithotripsy Stone Dis., vol. 3, 1:3–17
Coleman A.J., Saunders J.E. (1989) A survey of the acoustic output of commercial extracorporeal shock wave lithotripters; Ultrasound Med. Biol., vol. 15, 3:213–227
Preston R.C. (1991) Output measurements for medical ultrasound; Springer-Verlag, 57–73, 107–128
Filipczynski L., Etienne J. (1990) Capacitive hydrophones for pressure determination in lithotripsy. Ultrasound Med. Biol., vol. 16, 2:157–165
Staudenraus J., Eisenmenger W. (1993) Fibre-optic probe hydrophone for ultrasonic and shock wave measurements in water; Ultrasonic, vol. 31, 4:267–273
Granz B. (1989) PVDF hydrophone for the measurement of shock waves; IEEE Trans. Elect. Insulation, vol. 24, 3:499–502
Cathignol D. (1990) PVDF hydrophone with liquid electrodes for shock wave measurements; 1990 Ultrasonics symposium: Proceedings, 341–344
Schafer M.E. (1993) Cost-effective shock wave hydrophones; J. Stone. Dis., vol. 5, 2:73–76
Schafer M.E., Kraynak T., Krakhman V. (1994) Development of a cost-effective shock wave hydrophone; 1994 Ultrasonics symposium: Proceedings, 1805–1808
Schafer M.E., Kraynak T. (1991) Self-monitoring shock wave hydrophone; U.S.A. Patent 5072426; 10 December 1991
Cathignol D., Birer A., Nachef S., Chapelon J.Y. (1995) Electronic beam steering of shock waves; Ultrasound Med. Biol., vol. 21, 3:365–377
Nachef S. (1992) Générateur piezoelectrique d'ondes de choc a focalisation electronique; INSA de Lyon, Ph.D. thesis
Bauer F. (1987) Properties and high pressure shock loading response of poled ferroelectric PVF2 polymer gauges; The 1987 ASME Applied Mechanics Bioengineering and Fluid Engineering Conference, Cincinnati, Ohio; 14–17 June 1987
Bauer F. Procédé et dispositif pour polariser des matériaux ferroélectriques; French patent 8221025; U.S.A. patent 4611260
Preston R.C., Bacon D.R., Smith R.A. (1988) Calibration of medical ultrasonic equipment-Procedures and accuracy assessment; IEEE Trans. Ultrason. Ferroelec. Freq. Contr., vol. 35, 2:110–121
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Tavakkoli, J., Birer, A. & Cathignol, D. Development of a PVDF low-cost shock-wave hydrophone. Shock Waves 5, 369–374 (1996). https://doi.org/10.1007/BF02434012
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02434012