Abstract

During a few past years a series of shock-wave generators for lithotripsy and/or tissue destruction studies have been developed in our laboratory. Based on the experiences in shock wave measurements and the drawbacks in existing hydrophones, we have developed a very low-cost, wideband, reproducible shock-wave hydrophone. The key element of this device is the rapidly mounting, disposable PVDF membrane. This is a commercially available PVDF shock gauge which is poled by a patented cyclic poling technique. To obtain the widest possible bandwidth, we have adopted a special coplanar membrane design. The PVDF film is sandwiched between the surfaces of a P.V.C. and a metallic plate of brass which the latter is in contact with the surrounding medium. On the other hand, the active lead is isolated from medium and it is in contact with an isolating liquid (degassed petroleum) held in a cylindrical chamber over the membrane. By the incorporation of this design, the hydrophone can be used for shock wave measurements even in conductive media like different physiological liquids, with a negligible change of sensitivity.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Chaussy C., Brendel W., Schmiedt E. (1980) Extracorporeally induced destruction of kidney stones by shock waves; Lancet ii:1265–1268

    Article  Google Scholar 

  2. Coleman A.J., Saunders J.E. (1992) A review of the physical properties and biological effects of the high amplitude acoustic fields used in extracorporeal lithotripsy; Ultrasonics, vol. 31 2:75–85

    Google Scholar 

  3. Flynn H.G. (1964) Physics of acoustic cavitation in liquids, In: Mason W.P. ed., Physical acoustics: principals and methods; vol. 1B, New York, Academic press; 57–112

    Google Scholar 

  4. Coleman A.J., Saunders J.E., Crum L.A., Dyson M. (1987) Acoustic cavitation generated by an extracorporeal shock wave lithotripter; Ultrasound Med. Biol., 13:69–76

    Article  Google Scholar 

  5. Church C.C. (1989) A theoretical study of cavitation generated by an extracorporeal shock wave lithotripter; J. Acoust. Soc. Am., vol. 86, 1:215–227

    Article  MathSciNet  ADS  Google Scholar 

  6. Cathignol D., Chapelon J.Y. (1993) High energy ultrasound therapy, In: Hobaek H. ed., Advances in nonlinear acoustics; 13th International Symposium on Nonlinear Acoustics, Bergen, 30–35

  7. Chen Y.L., Israelachvili J. (1991) New mechanism of cavitation damage; Science, 252:1157–1160

    ADS  Google Scholar 

  8. Prat F., Cathignol D. (1994) Focused liver ablation by cavitation in the rabbit: A potential new method of extracorporeal treatment; Gut, 35:395–400

    Google Scholar 

  9. Lewin P.A., Schafer M.E. (1991) Shock wave sensors: I. Requirements and design; J. Lithotripsy Stone Dis., vol. 3, 1:3–17

    MATH  Google Scholar 

  10. Coleman A.J., Saunders J.E. (1989) A survey of the acoustic output of commercial extracorporeal shock wave lithotripters; Ultrasound Med. Biol., vol. 15, 3:213–227

    Article  Google Scholar 

  11. Preston R.C. (1991) Output measurements for medical ultrasound; Springer-Verlag, 57–73, 107–128

  12. Filipczynski L., Etienne J. (1990) Capacitive hydrophones for pressure determination in lithotripsy. Ultrasound Med. Biol., vol. 16, 2:157–165

    Article  Google Scholar 

  13. Staudenraus J., Eisenmenger W. (1993) Fibre-optic probe hydrophone for ultrasonic and shock wave measurements in water; Ultrasonic, vol. 31, 4:267–273

    Article  Google Scholar 

  14. Granz B. (1989) PVDF hydrophone for the measurement of shock waves; IEEE Trans. Elect. Insulation, vol. 24, 3:499–502

    Article  Google Scholar 

  15. Cathignol D. (1990) PVDF hydrophone with liquid electrodes for shock wave measurements; 1990 Ultrasonics symposium: Proceedings, 341–344

  16. Schafer M.E. (1993) Cost-effective shock wave hydrophones; J. Stone. Dis., vol. 5, 2:73–76

    Google Scholar 

  17. Schafer M.E., Kraynak T., Krakhman V. (1994) Development of a cost-effective shock wave hydrophone; 1994 Ultrasonics symposium: Proceedings, 1805–1808

  18. Schafer M.E., Kraynak T. (1991) Self-monitoring shock wave hydrophone; U.S.A. Patent 5072426; 10 December 1991

  19. Cathignol D., Birer A., Nachef S., Chapelon J.Y. (1995) Electronic beam steering of shock waves; Ultrasound Med. Biol., vol. 21, 3:365–377

    Article  Google Scholar 

  20. Nachef S. (1992) Générateur piezoelectrique d'ondes de choc a focalisation electronique; INSA de Lyon, Ph.D. thesis

  21. Bauer F. (1987) Properties and high pressure shock loading response of poled ferroelectric PVF2 polymer gauges; The 1987 ASME Applied Mechanics Bioengineering and Fluid Engineering Conference, Cincinnati, Ohio; 14–17 June 1987

  22. Bauer F. Procédé et dispositif pour polariser des matériaux ferroélectriques; French patent 8221025; U.S.A. patent 4611260

  23. Preston R.C., Bacon D.R., Smith R.A. (1988) Calibration of medical ultrasonic equipment-Procedures and accuracy assessment; IEEE Trans. Ultrason. Ferroelec. Freq. Contr., vol. 35, 2:110–121

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Tavakkoli, J., Birer, A. & Cathignol, D. Development of a PVDF low-cost shock-wave hydrophone. Shock Waves 5, 369–374 (1996). https://doi.org/10.1007/BF02434012

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02434012

Key words

Navigation