Abstract
A decreased renal function is rather common after renal transplantation. The causes of this decreased function are diverse and difficult to differentiate. Yet, duplex examination, and especially quantitative Doppler spectrum analysis of the blood velocities in the renal artery, may be an effective method for differentiating between some of these causes. Forty-five renal transplant recipients were included in this preliminary study. Doppler spectra were recorded from the renal artery to the allograft. Parameters were derived from every Doppler spectrum in order to characterize each spectrum. Renal allograft function was evaluated on the basis of a number of clinical parameters. A significant correlation was found between the clinical parameters and the Doppler spectrum parameters indicative for changes in the peripheral resistance. Patients with a normal renal allograft function showed Doppler spectra with a high diastolic flow, typical of a vascular bed with a low peripheral resistance. Patients with a decreased renal allograft function caused by a stenosis in the renal artery could be distinguished by a low peak velocity and a low pulsatility index. A decreased allograft function caused by allograft rejection or cyclosporin nephrotoxicity also led to characteristic arterial flow disturbances. In these cases, the peripheral resistance was increased, and this was primarily reflected in a decrease in the diastolic blood velocity. We conclude that quantitative analysis of the blood velocities in the renal artery by Doppler spectrum analysis seems to be a useful, noninvasive diagnostic tool that discriminates between some of the causes of a decreased renal allograft function.
Similar content being viewed by others
References
Arima M, Ishibashi M, Usami M, Sagawa S, Muzutana S, Sonoda T, Ichikawa S, Ihara H, Nagano S (1979) Analysis of the arterial blood flow patterns of normal and allografted kidneys by the directional ultrasonic Doppler technique. J Urol 122: 587–591
Arima M, Takahara S, Ihara H, Ichikawa Y, Ishibashi M, Sagawa S, Nagona S, Takaha M, Sonoda T (1982) Predictability of renal allograft prognosis during rejection crisis by ultrasonic Doppler flow technique. Urology 19 [Suppl 4]: 389–394
Arntz I, Wal H van de, Wijn P, Skotnicki S (1987) Quantitative assessment of vasospasm by Doppler spectrum analysis in patients with primary Raynaud's phenomenon. Eur J Vasc Surg 1: 19–28
Avasthi P, Voyles W, Greene E (1984) Noninvasive diagnosis of renal artery stenosis by echo-Doppler velocimetry. Kidney Int 25: 824–829
Berden J, Hoitsma A, Buijs W, Reekers P, Skotnicki S, De-Bruyne F, Koene R (1982) Results of kidney transplantations in Nijmegen (1968–1982). Neth J Med 25: 73–78
Berland L (1985) Doppler ultrasound secures role in abdominal diagnosis. Diagn Imag 1: 68–72
Blackshear W, Phillips D, Chikos P, Harley J, Thiele B, Strandness D (1979) Carotid artery velocity patterns in normal and stenotic vessels. Stroke 11: 67–71
Buckley A, Cooperberg P, Reeve C, Magil A (1987) The distinction between acute renal transplant rejection and cyclosporine nephrotoxicity: value of duplex sonography. AJR 149: 521–525
Cohen J (1968) Weighted kappa: nominal scale agreement with provision for scale disagreement of partial credit. Psychol Bull 70: 213–220
Dubbins P, (1986) Renal artery stenosis: duplex Doppler evaluation. Br J Radiol 59: 225–229
Fleiss J (1981) The measurement of interrater agreement. In: Statistical methods for rates and proportions. Wiley, New York, pp 212–236
Fronek A (1976) Quantitative ultrasonographic studies of lower extremity flow velocities in health and disease. Circulation 53: 957–960
Gosling R (1974) Arterial assessment by Doppler-shift ultrasound. Proc R Soc Med 67: 447–449
Greene E, Venters M, Avasthi P, Conn R, Jahnke R (1981) Non-invasive characterisation of renal artery blood flow. Kidney Int 20: 523–529
Landis J, Koch G (1977) The measurement of observer agreement for categorical data. Biometrics 33: 159–174
Maxwell M (1975) Cooperative study of renovascular hypertension: current status. Kidney Int 8: 153–160
McNeil B, Keeler E, Adelstein S (1975) Primer on certain elements of medical decision making. N Engl J Med 293: 211
Murphy A, Robertson R, Dubbins P (1987) Duplex ultrasound in the assessment of renal transplant complications. Clin Radiol 38: 229–234
Nicholls S, Kohler T, Martin R, Neff R, Phillips D, Strandness D (1986) Diastolic flow as a predictor of arterial stenosis. J Vasc Surg 3: 498–501
Phillips D, Powers J, Eyer M, Blackshear W, Bodily B, Strandness D, Baker D (1980) Detection of peripheral vascular disease using the duplex scanner III. Ultrasound Med Biol 6: 205–218
Planiol T, Pourcelot L (1974) Doppler effect study of the carotid circulation. In: Vlieger M, White D, McCready V (eds) Ultrasonics in medicine. Excerpta Medica, Amsterdam, pp 104–111
Reinitz E, Goldman M, Sais J, Rittgers S, Lee H, Mendez-Picon G, Muakkassa W, Barens R (1983) Evaluation of transplant renal artery flow by Doppler sound spectrum analysis. Arch Surg 118: 415–419
Rifkin M, Pasto M, Goldberg B (1985) Duplex Doppler examination in renal disease: evaluation of vascular involvement. Ultrasound Med Biol 11 [Suppl 2]: 341–346
Rifkin M, Needleman L, Pasto M, Kurtz A, Foy P, McGlynn E, Canino C, Baltarowich O, Pennell R Goldberg B (1987) Evaluation of renal transplant rejection by duplex Doppler examination: value of resistance index. AJR 148: 759–762
Rigsby C, Taylor K, Weltin G, Burns P, Bia M, Princenthal R, Kashgarian M, Flye W (1986) Renal allografts in acute rejection: evaluation using Doppler sonography. Radiology 158: 375–378
Rigsby C, Burns P, Weltin G, Chen B, Bia M, Taylor K (1987) Doppler signal quantitation in renal allografts: comparison in normal and rejecting transplants with pathologic correlation. Radiology 162: 39–42
Rittenhouse E, Maixner W, Burr J, Barnes R (1976) Directional artery flow velocity: a sensitive index of changes in peripheral vascular resistance. Surgery 79 [Suppl 3]: 350–355
Sampson D (1969) Ultrasonic method for detecting rejection in human renal allotransplants. Lancet II: 976–978
Taylor K, Burns P, Woodcock J, Wells P (1985) Blood flow in deep abdominal and pelvic vessels: ultrasonic pulsed Doppler analysis. Radiology 154: 487–493
Taylor K, Morse S, Rigsby C, Bia M, Schiff M (1987) Vascular complications in renal allografts: detection with duplex Doppler. Radiology 162: 31–38
Author information
Authors and Affiliations
About this article
Cite this article
Skotnicki, S.H., van Asten, W.N.J.C., Beijneveld, W.J. et al. Evaluation of renal allograft function by Doppler spectrum analysis. Transplant Int 2, 16–22 (1989). https://doi.org/10.1007/BF02425966
Issue Date:
DOI: https://doi.org/10.1007/BF02425966