Quality assurance features of “HYPERMET-PC”

  • Advances in Nuclear Instrumentation and Software
  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

The γ-ray spectrum analysis code HYPERMET-PC has been significantly upgraded since its introduction in the firstk 0-Users Workshop (1992). Some aspects of the implemented procedures in the new version 5.0, such as the novel approach to handle tandem LFC spectra and the benefit of using ortho-normal polynomials for fitting efficiency curves will be outlined. Having realized the importance of quality assurance in applied γ-ray spectrometry, additional utilities have been incorporated for checking system parameters: nonlinearity, energy resolution, etc. The new Nuclide Identification routine makes the program suitable for qualitative analysis both of NAA and PGAA type.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. G. W. Philips, K. W. Marlow, Nucl. Instr. Meth., 72 (1976) 125.

    Google Scholar 

  2. L. Moens, J. De Donder, Lin Xiley, F. De Corte, A. De Wispelaere, A. Simonits, J. Hoste, Nucl. Instr. Methods, 187 (1981) 451.

    Article  CAS  Google Scholar 

  3. R. G. Helmer, J. E. Cline, R. C. Greenwood, Gamma-Ray Energy and Intensity Measurements with Ge(Li) Spectrometers, in: The Electromagnetic Interaction in Nuclear Spectroscopy,W. D. Hamilton (Ed.), 1975.

  4. W. Ledermann, E. Lloyd, Handbook of Applicable Mathematics, Vol. 6, Statistics, Part A, 1984.

  5. KAYZERO/SOLCOI for Reactor Neutron Activation Analysis (NAA) Using thek 0 Standardization Method, User's Manual, DSM Research, Geleen, The Netherlands, Version 4, December 1996.

  6. B. Fazekas, G. Molnár, T. Belgya, L. Dabolczi, A. Simonits, J. Radioanal. Nucl. Chem, 215 (1997) 271.

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Fazekas, B., Östör, J., Kiss, Z. et al. Quality assurance features of “HYPERMET-PC”. J Radioanal Nucl Chem 233, 101–103 (1998). https://doi.org/10.1007/BF02389654

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02389654

Keywords

Navigation