Hydrotechnical Construction

, Volume 1, Issue 7, pp 641–644 | Cite as

Calculation of dam buttresses with an active joint

  • V. A. Shabanov
Papers Meeting the 50th Anniversary of Soviet Power

Conclusions

  1. 1.

    The proposed method of calculating buttresses for the effect of forces in an active joint gives a sufficiently good agreement with experiment.

     
  2. 2.

    Compressive stresses arise in the active joint on the upstream face of the buttress from the effect of the force.

     
  3. 3.

    When Eb=E0 the base noticeably influences the distribution of streses only in the lower part of the buttress with a height 0.25 H.

     

Keywords

Energy Source Power Generation Compressive Stress Power Engineer Renewable Energy Source 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Literature Cited

  1. 1.
    A. A. Senkevich, Use of Prestressing in Hydraulic Structures [in Russian], Stroiizdat (1960).Google Scholar
  2. 2.
    P. V. Melent'ev, Approximate Calculations [in Russian], Fizmatgiz (1962).Google Scholar