Skip to main content
Log in

New polyester arterial prostheses from great britain: anin vitro andin vivo evaluation

  • Published:
Annals of Biomedical Engineering Aims and scope Submit manuscript

Abstract

Two models of knitted velour polyester prostheses have been developed in Great Britain, i.e. the VP1200K and the VP50K Triaxial. The evaluation of these new devices in vitro and in vivo in dogs has demonstrated that, while the first model has similar surgical, mechanical and healing characteristics in the short term to other commercial knitted velour prostheses, the second model has lower water permeability and superior strength and dimensional stability. On the basis of these results, clinical investigations can be undertaken.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. DeBakey, M. The development of vascular surgery.Am. J. Surg. 137:697–738, 1979.

    Article  CAS  PubMed  Google Scholar 

  2. Glickman, M.H., R.L. Hurwitz, S.A. Kimmins and W.E. Evans. Employment following peripheral vascular surgery: an increasingly critical issue.Surgery 93:50–53, 1983.

    CAS  PubMed  Google Scholar 

  3. Leijala, M. Complications of synthetic arterial grafting. A retrospective study of 489 patients. PhD Thesis. University of Helsinki, 1976.

  4. Mortensen, J.D. Safety and performance of currently available vascular prostheses. A review.ASAIO J. 4:125–138, 1981.

    Google Scholar 

  5. Guidoin, R., M. King, C. Gosselin, P. Blais, K. Gunasekera, M. Marois and A. Cardou. Les prothèses artérielles en polyester.Rev. Eur. Biotech. Med. 4:13–25, 1982.

    Google Scholar 

  6. King, M.W., R. Guidoin, K. Gunasekera, L. Martin, M. Marois, P. Blais, J.M. Maarek and C. Gosselin. An evaluation of Czechoslovakian polyester arterial prostheses.ASAIO J. 7:114–133, 1984.

    Google Scholar 

  7. Buxton, B.F., D.C. Wukasch, C. Martin, W.J. Liebig, G.L. Hallman and D.A. Cooley. Practical considerations in fabric and vascular grafts. Introduction of a new bifurcated graft.Am. J. Surg. 125:288–293, 1973.

    Article  CAS  PubMed  Google Scholar 

  8. ISO DP 7198,Cardiovascular Implants-Draft Standard for Synthetic Tubular Vascular Prostheses, Association for the Advancement of Medical Instrumentation, Arlington, VA, October 1984.

  9. McCune, W.S. and B. Blades. The viability of long blood vessel grafts.Ann. Surg. 124:769–781, 1954.

    Google Scholar 

  10. Burkel, W.E., D.W. Winter, J.W. Ford, R.H. Kahn, L.M. Graham and J.C. Stanley. Sequential studies of healing in endothelial seeded vascular prostheses: histological and ultrastructure characteristics of graft incorporation.J. Surg. Res. 30:305–324, 1981.

    Article  CAS  PubMed  Google Scholar 

  11. Goëau-Brissonnière, A., R. Guidoin, M. Marois, B. Boyce, J.C. Pechere, P. Blais, H.P. Noel and C. Gosselin. Thoracoabdominal bypass as a method of evaluating vascular grafts in the dog.Biomater. Med. Devices Artif. Organs 9:195–212, 1981.

    PubMed  Google Scholar 

  12. Bernier, J. and R. Guidoin. Importance des facteurs thrombodynamiques dans la thrombose aiguë dans les prothèses artérielles.Rev. Eur. Biotech. Med. 4:103–113, 1982.

    Google Scholar 

  13. Guidoin, R., C. Gosselin, L. Martin, M. Marois, F. Laroche, M. King, K. Gunasekera, D. Domurado, M.F. Sigot-Luizard and P. Blais. Polyester prostheses as substitutes in the thoracic aorta of dogs. I. Evaluation of commercial prostheses.J. Biomed. Mater. Res. 17:1049–1077, 1983.

    Article  CAS  PubMed  Google Scholar 

  14. Nunn, D.B., M.H. Freeman and P.C. Hudgins. Postoperative alterations in size of Dacron aortic grafts. An ultrasonic evaluation.Ann. Surg. 189:741–745, 1979.

    CAS  PubMed  Google Scholar 

  15. Melliere, D., G. Lasry and F. Lange. Résultats et indications des prothèses en chirurgie artérielle.J. Chirc. (Paris) 116:285–296, 1979.

    CAS  Google Scholar 

  16. King, M., P. Blais, R. Guidoin, E. Prowse, M. Marois, C. Gosselin and H.P. Noel. Polyethylene terephthalate (Dacron) vascular prostheses-material and fabric construction aspects. In:Biocompatibility of Clinical Implants Materials, edited by D.F. Williams. Boca Rato, Florida: CRC, 1981, Vol. 2, pp. 177–207.

    Google Scholar 

  17. Yates, S.G., A.A.B. Barros, K. Berger, L.G. Fernandez, S.J. Wood, E.A. Rittenhouse, C.C. Davis, P.B. Mansfield and L.R. Sauvage. The preclotting of porous arterial prostheses.Ann. Surg. 188:611–622, 1978.

    CAS  PubMed  Google Scholar 

  18. Berger, K., L.R. Sauvage, A.M. Rao and S.J. Wood. Healing of arterial prostheses in man: its incompleteness.Ann. Surg. 175:118–127, 1972.

    CAS  PubMed  Google Scholar 

  19. Guidoin, R., M. King, P. Blais, M. Marois, C. Gosselin, P. Roy, R. Courbier, M. David and H.P. Noel. A biological and structural evaluation of retrieved Dacron arterial prostheses.NBS Special Report 601:29–129, 1981.

    Google Scholar 

  20. Sawyer, P.N., B. Stanczewski, R. Turner and H. Hoffman. Evaluation of chemical compacting techniques on the performance, thrombosis rate, histology and healing of experimental similary fabricated Dacron prostheses.Trans. Am. Soc. Artif. Intern. Organs 24:215–222, 1978.

    CAS  PubMed  Google Scholar 

  21. Sauvage, L.R., K.E. Berger, S.J. Wood, S.G. Yates II, J.C. Smith and P.B. Mansfield. Interspecies healing of porous arterial prostheses.Arch. Surg. 109:698–705, 1974.

    CAS  PubMed  Google Scholar 

  22. Bruck, S.D., Considerations of species related hematological differences on the evaluation of biomaterials.Biomater. Med. Devices Artif. Organs 5:97–113, 1977.

    CAS  PubMed  Google Scholar 

  23. Guidoin, R., L. Martin, M. Marois, C. Gosselin, M. King, K. Gunasekera, D. Domurado, M.F. Sigot-Luizard, M. Sigot and P. Blais. Polyester prostheses as substitutes in the thoracic aorta of dogs. II. Evaluation of albuminated polyester grafts stored in ethanol.J. Biomed. Mater. Res. 18:1059–1072. 1984.

    Article  CAS  PubMed  Google Scholar 

  24. Guidoin, R.G., W.M. King, J. Awad, L. Martin, D. Domurado, M. Marois, M.F. Sigot-Luizard, C. Gosselin, K. Gunasekera and D. Gagnon. Albumin coated and critical point dried polyester prostheses as substitutes in the thoracic aorta of dogs.Trans. Am. Soc. Artif. Intern. Organs 29:290–295, 1983.

    CAS  PubMed  Google Scholar 

  25. King, M., R. Guidoin, C. Gosselin, F. Godard, M. Marois, K. Gunasekera, P. Blais and A. Garton. Protocole d'étude d'une greffe artérielle en polyester après exérèse. Les standards sont-ils utiles ou désagreables?Rev. Eur. Biotech. Med. 4:26–33, 1982.

    Google Scholar 

  26. King, W.M.R. Guidoin, P. Blais, A. Garton and A. Gunasekera. Degradation of polyester arterial prostheses: a physical or chemical mechanism? In:Corrosion and Degradation of Implant Materials, edited by A.C. Fraker and C.D. Griffin. STP 859, Philadelphia: ASTM, 1985, pp. 294–307.

    Google Scholar 

  27. Godard, F., M. King, R. Guidoin, M. Marois, A. Garton, P. Blais, C. Gosselin and K. Gunasekera. Formation anévrismale sur prothèse artérielle synthetique—analyse pathologique, structurale et chimique d'une greffe en polyester après 84 mois d'implantation.J. Mal. Vasc. (Paris) 6:167–171, 1981.

    CAS  Google Scholar 

  28. Marceau, D., A. Cardou, R. Guidoin, M. King and C. Gosselin. Development d'un système d'essai pour l'étude du comportement dynamique des prothèses artérielles alloplastiques: le Vivocycleur.Rev. Eur. Biotech. Med. 6:31–38, 1984.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Guidoin, R.G., King, M., Marois, M. et al. New polyester arterial prostheses from great britain: anin vitro andin vivo evaluation. Ann Biomed Eng 14, 351–367 (1986). https://doi.org/10.1007/BF02367408

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02367408

Keywords

Navigation