Abstract
Two models of knitted velour polyester prostheses have been developed in Great Britain, i.e. the VP1200K and the VP50K Triaxial. The evaluation of these new devices in vitro and in vivo in dogs has demonstrated that, while the first model has similar surgical, mechanical and healing characteristics in the short term to other commercial knitted velour prostheses, the second model has lower water permeability and superior strength and dimensional stability. On the basis of these results, clinical investigations can be undertaken.
Similar content being viewed by others
References
DeBakey, M. The development of vascular surgery.Am. J. Surg. 137:697–738, 1979.
Glickman, M.H., R.L. Hurwitz, S.A. Kimmins and W.E. Evans. Employment following peripheral vascular surgery: an increasingly critical issue.Surgery 93:50–53, 1983.
Leijala, M. Complications of synthetic arterial grafting. A retrospective study of 489 patients. PhD Thesis. University of Helsinki, 1976.
Mortensen, J.D. Safety and performance of currently available vascular prostheses. A review.ASAIO J. 4:125–138, 1981.
Guidoin, R., M. King, C. Gosselin, P. Blais, K. Gunasekera, M. Marois and A. Cardou. Les prothèses artérielles en polyester.Rev. Eur. Biotech. Med. 4:13–25, 1982.
King, M.W., R. Guidoin, K. Gunasekera, L. Martin, M. Marois, P. Blais, J.M. Maarek and C. Gosselin. An evaluation of Czechoslovakian polyester arterial prostheses.ASAIO J. 7:114–133, 1984.
Buxton, B.F., D.C. Wukasch, C. Martin, W.J. Liebig, G.L. Hallman and D.A. Cooley. Practical considerations in fabric and vascular grafts. Introduction of a new bifurcated graft.Am. J. Surg. 125:288–293, 1973.
ISO DP 7198,Cardiovascular Implants-Draft Standard for Synthetic Tubular Vascular Prostheses, Association for the Advancement of Medical Instrumentation, Arlington, VA, October 1984.
McCune, W.S. and B. Blades. The viability of long blood vessel grafts.Ann. Surg. 124:769–781, 1954.
Burkel, W.E., D.W. Winter, J.W. Ford, R.H. Kahn, L.M. Graham and J.C. Stanley. Sequential studies of healing in endothelial seeded vascular prostheses: histological and ultrastructure characteristics of graft incorporation.J. Surg. Res. 30:305–324, 1981.
Goëau-Brissonnière, A., R. Guidoin, M. Marois, B. Boyce, J.C. Pechere, P. Blais, H.P. Noel and C. Gosselin. Thoracoabdominal bypass as a method of evaluating vascular grafts in the dog.Biomater. Med. Devices Artif. Organs 9:195–212, 1981.
Bernier, J. and R. Guidoin. Importance des facteurs thrombodynamiques dans la thrombose aiguë dans les prothèses artérielles.Rev. Eur. Biotech. Med. 4:103–113, 1982.
Guidoin, R., C. Gosselin, L. Martin, M. Marois, F. Laroche, M. King, K. Gunasekera, D. Domurado, M.F. Sigot-Luizard and P. Blais. Polyester prostheses as substitutes in the thoracic aorta of dogs. I. Evaluation of commercial prostheses.J. Biomed. Mater. Res. 17:1049–1077, 1983.
Nunn, D.B., M.H. Freeman and P.C. Hudgins. Postoperative alterations in size of Dacron aortic grafts. An ultrasonic evaluation.Ann. Surg. 189:741–745, 1979.
Melliere, D., G. Lasry and F. Lange. Résultats et indications des prothèses en chirurgie artérielle.J. Chirc. (Paris) 116:285–296, 1979.
King, M., P. Blais, R. Guidoin, E. Prowse, M. Marois, C. Gosselin and H.P. Noel. Polyethylene terephthalate (Dacron) vascular prostheses-material and fabric construction aspects. In:Biocompatibility of Clinical Implants Materials, edited by D.F. Williams. Boca Rato, Florida: CRC, 1981, Vol. 2, pp. 177–207.
Yates, S.G., A.A.B. Barros, K. Berger, L.G. Fernandez, S.J. Wood, E.A. Rittenhouse, C.C. Davis, P.B. Mansfield and L.R. Sauvage. The preclotting of porous arterial prostheses.Ann. Surg. 188:611–622, 1978.
Berger, K., L.R. Sauvage, A.M. Rao and S.J. Wood. Healing of arterial prostheses in man: its incompleteness.Ann. Surg. 175:118–127, 1972.
Guidoin, R., M. King, P. Blais, M. Marois, C. Gosselin, P. Roy, R. Courbier, M. David and H.P. Noel. A biological and structural evaluation of retrieved Dacron arterial prostheses.NBS Special Report 601:29–129, 1981.
Sawyer, P.N., B. Stanczewski, R. Turner and H. Hoffman. Evaluation of chemical compacting techniques on the performance, thrombosis rate, histology and healing of experimental similary fabricated Dacron prostheses.Trans. Am. Soc. Artif. Intern. Organs 24:215–222, 1978.
Sauvage, L.R., K.E. Berger, S.J. Wood, S.G. Yates II, J.C. Smith and P.B. Mansfield. Interspecies healing of porous arterial prostheses.Arch. Surg. 109:698–705, 1974.
Bruck, S.D., Considerations of species related hematological differences on the evaluation of biomaterials.Biomater. Med. Devices Artif. Organs 5:97–113, 1977.
Guidoin, R., L. Martin, M. Marois, C. Gosselin, M. King, K. Gunasekera, D. Domurado, M.F. Sigot-Luizard, M. Sigot and P. Blais. Polyester prostheses as substitutes in the thoracic aorta of dogs. II. Evaluation of albuminated polyester grafts stored in ethanol.J. Biomed. Mater. Res. 18:1059–1072. 1984.
Guidoin, R.G., W.M. King, J. Awad, L. Martin, D. Domurado, M. Marois, M.F. Sigot-Luizard, C. Gosselin, K. Gunasekera and D. Gagnon. Albumin coated and critical point dried polyester prostheses as substitutes in the thoracic aorta of dogs.Trans. Am. Soc. Artif. Intern. Organs 29:290–295, 1983.
King, M., R. Guidoin, C. Gosselin, F. Godard, M. Marois, K. Gunasekera, P. Blais and A. Garton. Protocole d'étude d'une greffe artérielle en polyester après exérèse. Les standards sont-ils utiles ou désagreables?Rev. Eur. Biotech. Med. 4:26–33, 1982.
King, W.M.R. Guidoin, P. Blais, A. Garton and A. Gunasekera. Degradation of polyester arterial prostheses: a physical or chemical mechanism? In:Corrosion and Degradation of Implant Materials, edited by A.C. Fraker and C.D. Griffin. STP 859, Philadelphia: ASTM, 1985, pp. 294–307.
Godard, F., M. King, R. Guidoin, M. Marois, A. Garton, P. Blais, C. Gosselin and K. Gunasekera. Formation anévrismale sur prothèse artérielle synthetique—analyse pathologique, structurale et chimique d'une greffe en polyester après 84 mois d'implantation.J. Mal. Vasc. (Paris) 6:167–171, 1981.
Marceau, D., A. Cardou, R. Guidoin, M. King and C. Gosselin. Development d'un système d'essai pour l'étude du comportement dynamique des prothèses artérielles alloplastiques: le Vivocycleur.Rev. Eur. Biotech. Med. 6:31–38, 1984.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Guidoin, R.G., King, M., Marois, M. et al. New polyester arterial prostheses from great britain: anin vitro andin vivo evaluation. Ann Biomed Eng 14, 351–367 (1986). https://doi.org/10.1007/BF02367408
Issue Date: