Abstract
The effects of in-series mechanical assistance on left ventricular (LV) afterload and aortic power dissipation were studied in four groups of open chest mongrel dogs: control, acute myocardial ischemia, cholinergic and beta-adrenergic blockade, and combined ischemia and blockade. Aortic root pressure, flow, power, and impedance and LV pressure and power were obtained. Assistance was provided by intraaortic balloon pumping. Times of inflation and deflation of the balloon were controlled to maintain a phase difference of 180° between the fundamental components of aortic root pressure and flow. Differences in hemodynamic parameters before and after 2–5 min of cardiac assistance were calculated. The results confirm other observations regarding effects of in-series assistance on LV and aortic pressure, cardiac output, and peripheral resistance. No consistent changes were obtained in the pulsatile components of aortic input impedance. A significant decrease (14–20%) was observed in the dc component of the impedance in all animals. The results reported here contradict previous reports regarding decreased LV power generation. It was found that LV power generation and aortic power dissipation increased significantly during assistance (LV, 3–17%; aortic, 4–19%). The results of this investigation also appear to conflict with previous reports regarding the role of cardiovascular control in “counteracting” the effects of assistance in the normal experimental preparation. They suggest that the short term effects are attributable directly to the device and are not mediated by the autonomic nervous system.
Similar content being viewed by others
References
Abel, F. L. Fourier analysis of left ventricular performance.Circulation Research 1971,28, 119–135.
Benchimol, A., Desser, K. B., and Garlton, J. L. Left ventricular blood flow velocity in man studied with the doppler ultrasonic flowmeter.American Heart Journal 1973,85, 294–301.
Bleifeld, W., Franken, G., Meyer, J., and Bussmann, W. D. The response of mechanical performance, coronary blood flow and myocardial oxygen consumption of the normal and failing dog heart to intraaortic balloon pulsation.Basic Research in Cardiology 1974,4, 379–401.
Chatterjee S., and Rosensweig, J. Evaluation of intraaortic balloon counterpulsation.Journal of Thoracic and Cardiovascular Surgery 1971,61, 405–410.
Cooper, T., and Dempsey, P. J. Assisted circulation I and II.Modern Concepts of Cardiovascular Disease 1968,37, 95–100, 101–106.
Corday, E., Swan, H. J. C., Lang, T., Goldman, A., Matloff, J. M., Gold, H., and Meerbaum, S. Physiologic principles in the application of circulatory assist for the failing heart.American Journal of Cardiology 1970,26, 595–602.
Cox, R. H. Determinants of systemic hydraulic power in unanesthetized dogs.American Journal of Physiology 1974,226, 579–587.
Evans, D. Support of the circulation by mechanical means: a review.Canadian Anasthetists Society Journal 1971,18, 650–664.
Feola, M., Limet, R. R., and Glick, G. Direct and reflex vascular effects of intraaortic balloon counterpulsation in dogs.American Journal of Physiology 1971,221, 748–753.
Feola, M., Normann, N. A., Haiderez, O., and Kennedy, J. H. Assisted circulation: experimental intraaortic balloon pumping. InProceedings of the artificial heart program conference, 1969. Pp. 637–656.
Goldfarb, D. Mechanical circulatory assistance in the treatment of cardiac failure.Progress in Cardiovascular Disease 1969,12, 221–242.
Goldfarb, D., Brown, B. G., Conti, C. R., and Gott, V. L. Cardiovascular responses to diastolic augmentation in the intact canine circulation after ligation of the anterior descending coronary artery.Journal of Thoracic and Cardiovascular Surgery 1968,55, 243–254.
Hahnloser, P. B., Gallo, E., and Schenk, W. G. The hemodynamics of counterpulsation.Journal of Thoracic and Cardiovascular Surgery 1966,51, 366–378.
Jaron, D., Tomecek, J., Freed, P. S., Welkowitz, W., Fich, S., and Kantrowitz, A. Measurement of ventricular load phase angle as an operating criterion for in-series assist devices: hemodynamic studies utilizing intraaortic balloon pumping.Transactions, American Society for Artificial Internal Organs 1970,16, 466–471.
Jelinek, J. Hemodynamics of counterpulsation: The study of a lumped-parameter computer model.Journal of Biomechanics 1972,5, 511–519.
Jose, A. D., Stitt, F. Cardiac function after combined betaadrenergic and cholinergic blockade.Circulation Research 1967,20, III-231–III-242.
Jose, A. D., and Taylor, R. R. Autonomic blockade by propranolol and atropine to study intrinsic myocardial function in man.Journal of Clinical Investigations, 1969,48, 2019–2031.
Kolff, W. J., Moulopoulos, S. D., Kwan-Gett, C. S., and Kralios, A. Mechanical assistance to the circulation: The principle and the methods.Progress in Cardiovascular Disease 1969,12, 243–270.
Milnor, W. R. Arterial impedance as ventricular afterload.Circulation Research 1975,36, 565–570.
Milnor, W. R., Bergel, D. H., and Bargainer, J. D. Hydraulic power associated with pulmonary blood flow and its relation to heart rate.Circulation Research 1966,19, 467–480.
Mullins, C. G., Sugg, W. L., Kennelly, B. M., Jones, D. C., and Mitchell, J. H. Effect of arterial counterpulsation on left ventricular volume and pressure.American Journal of Physiology 1971,220, 694–698.
O'Rourke, M. F. Steady and pulsatile energy losses in the systemic circulation under normal conditions and in simulated arterial disease.Cardiovascular Research 1967,1, 313–326.
Powell, W. J., Daggett, W. M., Magro, A. E., Bianco, J. A., Buckley, M. J., Sanders, C. A., Kantrowitz, A. R., and Austen, W. G. Effects of intraaortic balloon counterpulsation on cardiac performance, oxygen consumption and coronary blood flow in dogs.Circulation Research 1970,26, 753–764.
Resnekov, L. Mechanical assistance for the failing heart.Modern Concepts of Cardiovascular Disease 1974,43, 81–85.
Robinson, B. F., Epstein, S. E., Beiser, G. D., and Braunwald, E. Control of heart rate by the autonomic nervous system.Circulation Research 1966,19, 400–411.
Sanders, C. A., Buckley, M. J., Leinbach, R. C., Mundth, E. D., and Austen, W. G. Mechanical circulatory assistance: Current status and experience with combining circulatory assistance, emergency coronary angiography and acute myocardial revascularization.Circulation 1972,45, 1292–1313.
Schilt, W., Freed, P. S., Khalil, G., and Kantrowitz, A. Temporary non-surgical intraarterial cardiac assistance.Transactions, American Society for Artificial Internal Organs 1967,13, 322–326.
Soroff, H. S., Levine, H. J., Sachs, B. F., Birtwell, W. C., and Deterling, R. A. Assisted circulation. II. Effects of counter pulsation on left ventricular oxygen consumption and hemodynamics.Circulation 1963,27, 722–731.
Sugg, W. L., Martin, L. F., Webb, W. R., and Ecker, R. R. Influence of counterpulsation on aortic right and left coronary blood flow following ligation of the left circumflex coronary artery.Journal of Thoracic and Cardiovascular Surgery 1970,59, 345–351.
Tanaka, S., Rassman, W., Lande, A., Kaster, R., and Lillehei, C. W. Cardiovascular responses of the failing dog heart to counterpulsation.Journal of Thoracic and Cardiovascular Surgery 1969,58, 112–121.
Urschel, C. W., Eber, L., Forrester, J., Matloff, J., Carpenter, R., and Sonnenblick, E. Alteration of mechanical performance of the ventricle by intraaortic balloon counterpulsation.American Journal of Cardiology 1970,25, 546–551.
Weber, K. T., Janicki, J. S. Intraaortic balloon counterpulsation: A review of physiological principles, clinical results and device safety.Annals of Thoracic Surgery 1974,17, 602–636.
Weber, K. T., Janicki, J. S., Walker, A. A., and Kirklin, J. W. An assessment of intraaortic balloo pumping in hypovolemic and ischemic heart preparations.Journal of Thoracic and Cardiovascular Surgery 1972,64, 869–877.
Westerhof, N., Noordergraaf, A. Errors in the measurements of hydraulic input impedance.Journal of Biomechanics 1969,3, 351–356.
Yahr, W., Butner, A. N., Krakauer, J. S., Phillips, S. J., Freed, P. S., Jaron, D., and Kantrowitz, A. Intraaortic phase-shift balloon pumping in the treatment of cardiogenic shock.Journal of the Association for the Advancement of Medical Instrumentation 1969,3, 100–105.
Author information
Authors and Affiliations
Additional information
This work was supported in part by SUPHS Grant HL-13737 to Sinai Hospital and by NSF Grant ENG 74-21085 to the University of Rhode Island.
Portions of this investigation were performed while D. Jaron was Director of the Surgical Research Laboratory at Sinai Hospital of Detroit.
Rights and permissions
About this article
Cite this article
Jaron, D. Left ventricular afterload and systemic hydraulic power during in-series cardiac assistance: Studies using intraaortic balloon pumping in dogs. Ann Biomed Eng 5, 95–110 (1977). https://doi.org/10.1007/BF02364010
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF02364010