Advertisement

Effects of ionic radiological and chemical interferences on the chromatographic separation of a radionuclide standard solution

  • J. E. Roane
  • T. A. DeVol
  • J. D. Leyba
  • R. A. Fjeld
Article

Abstract

For characterizing radioactive samples there are two major considerations in the application of a coupled liquid chromatography and on-line scintillation counting system: (1) radiological interferences and (2) chemical interferences from the matrix. A study was conducted to identify which interferences from typical matrices found at several Department of Energy facilities affected the separation of a radioactive tracer solution by the coupled system. The selection of potential interferent materials was determined through a review of characterization and monitoring studies of surface water, ground water, and high level waste tank supermatant at those facilities. Incremental mass loadings of contaminant were mixed with a standardized radioactive tracer (55Fe,63Ni,90Sr and147Pm) and then injected into a coupled system. The resultant chromatograms were compared to the chromatogram of the standard radionuclide solution to determine the effects of the chemical or radiological constituent. Relative to the radionuclide solution,137Cs was the only activation/fission product used in this study to effect a radiological interference. For the natural uranium series, a radiological interference was observed for90Sr due to either a uranium isotope or a decay product of the series. No rad interference was observed from228Th, though it must be noted that the elution program was not capable of completely separating the decay series nuclides of natural uranium or thorium. For the chemical interferences, the effects are twofold since the chemical can affect the concentration of ions on the pre-concentration stage as well as the chromatographic separation. The general trend observed was that increasing the ionic strength of the chemical resulted in decreased retention fractions on the pre-concentration column and significant shifts in peak elution times.

Keywords

Uranium Thorium Radioactive Tracer Natural Uranium Uranium Isotope 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    E. Schram, R. Lombaert, Arch. Intern. Physiol. Biochem., 68 (1960) 845.Google Scholar
  2. 2.
    H. Parvez, A. Reich, S. Lucas-Reich, S. Parvez, Flow-Through Radioactivity in HPLC, VSP, Utrecht, The Netherlands, 1988.Google Scholar
  3. 3.
    D. Bradbury, G. R. Elder, M. J. Dunn, Rapid Analysis of Non-Gamma Radionuclides Using the ANABET System, in:R. G. Post (Ed.), Waste Management '90, Proc. Symp. on Waste Management, Tucson, Arizona, 1990.Google Scholar
  4. 4.
    R. A. Fjeld, S. Guha, T. A. DeVol, J. D. Leyba, J. Radioanal. Nucl. Chem., 194 (1995) 51.Google Scholar
  5. 5.
    S. H. Reboul, R. A. Fjeld, Radioact. Radiochem., 5 (1994) No. 3, 42.Google Scholar
  6. 6.
    S. H. Reboul, R. A. Fjeld, J. Chromatogr., to be published.Google Scholar
  7. 7.
    S. Guha, J. E. Roane, T. A. DeVol, J. D. Leyba, R. A. Fjeld, Ion Chromatography Coupled with On-line and Off-line Radiation Detection for the Rapid Analysis of Radionuclides in Reactor Coolant Water, in:R. G. Post (Ed.), Waste Management '95, Proc. Symp. on Waste Management, Tucson, Arizona, 1995.Google Scholar
  8. 8.
    O. T. Farmer III, J. H. Reeves, E. J. Wyse, C. J., Clemetson, C. J. Barinaga, M. R. Smith, D. W. Koppenaal, Analysis of Radioactive Waste Samples by Ion Chromatography-beta-ICPMS, Applications of Inductively Coupled Plasma-Mass Spectrometry to Radionuclide Determinations, ASTM STP 1291,R. W. Morrow andJ. S. Crain (Eds), American Society of Testing and Materials, West Conshohocken, 1995, p. 38.Google Scholar
  9. 9.
    C. A. Lucy, LC-GC, 14 (1996) No. 5, 406.Google Scholar
  10. 10.
    R. S. Ondrejcin, Chemical Compositions of Supermates Stored in SRP High Level Waste Tanks, DP-1347/UC-70, E. I. duPont de Nemours & Co., Savannah River Laboratory, August 1974.Google Scholar
  11. 11.
    Environmental Surveillance at Los Alamos during 1991. Los Alamos report, LA-1257-ENV, August 1993.Google Scholar
  12. 12.
    V. L. Snoeyink, D. Jenkins, Water Chemistry, John Wiley & Sons, Inc., New York, 1980.Google Scholar
  13. 13.
    J. Weiss, Ion Chromatography, 2nd ed., VCH Publishers, Inc., New York, 1995.Google Scholar
  14. 14.
    N. G. L. Harding, Y. Farid, M. J. Stewart, J. Shepherd, D. Nicoll, Chromatographia, 15 (1982) No. 7, 468.Google Scholar
  15. 15.
    A. E. Martell, R. M. Smith, Critical Stability Constants, Vol. 4, Inorganic Complexes, Plenum Press, New York, 1974.Google Scholar

Copyright information

© Akadémiai Kiadó 1999

Authors and Affiliations

  • J. E. Roane
    • 1
  • T. A. DeVol
    • 1
  • J. D. Leyba
    • 2
  • R. A. Fjeld
    • 1
  1. 1.Department of Environmental Engineering and ScienceClemson UniversityClemsonUSA
  2. 2.Savannah River Technology CenterWestinghouse Savannah River Co.SCAikenUSA

Personalised recommendations